ControlWave Upgrade Kits

Emerson Process Management

Remote Automation Solutions

Watertown, CT  06795  USA   

T  1 (860) 945-2200

Mississauga, ON  06795  Canada 

T  1 (905) 362-0880

Worcester  WR3 8YB  UK 

 

T  44 (1) 905-856950

Website:  www.EmersonProcess.com/Remote

©  2007 Remote Automation Solutions, division of Emerson Process Management.  All rights reserved.
Bristol, Inc., Bristol Babcock Ltd, Bristol Canada, BBI SA de CV and the Flow Computer Division , are wholly owned subsidiaries of Emerson Electric Co. doing business as Remote Auto-
mation Solutions (“RAS”), a division of Emerson Process Management.  FloBoss, ROCLINK, Bristol, Bristol Babcock, ControlWave, TeleFlow and Helicoid are trademarks of RAS.  AMS, 
PlantWeb and the PlantWeb logo are marks of Emerson Electric Co. The Emerson  logo is a trademark and service mark of the Emerson Electric Co.  All other marks are property of their 
respective owners.
The contents of this publication are presented for informational purposes only.  While every effort has been made to ensure informational accuracy, they are not to be construed as war-
ranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability.  RAS reserves the right to modify or improve the designs or 

specifications of such products at any time without notice.  All sales are governed by RAS’ terms and conditions which are available upon request.   RAS does not assume responsibility for 

the selection, use or maintenance of any product.  Responsibility for proper selection, use and maintenance of any RAS product remains solely with the purchaser and end-user.

Selection Item Descriptions And Specifications

Communications

CW_10

CW_30/35

2 BIP ports (RS232/ 485 jumper selectable) replacements - full serial async ports - No 

sync comm

N/A

Yes

1 or 2 10/100 Ethernet ports

Yes

4 built-in serial asynchronous ports on MFIB - 1 RS232 and 3 selectable RS232/ 485

Yes

N/A

4 port communications board - no synchronous ports supported

Yes

Communications Options

Selectable RS232/ 485 ports

Yes

Yes

Support for RDI

Yes

Yes

Support for TIB

Yes

Yes

Support for 1200 baud modem

Yes

Yes

Support for 9600 baud modem

Yes

Yes

Support for MIB

Yes

Support for fiber modem

Yes

Support for external CDMA and GSM/ GPRS Modems

Yes

Yes

I/O Boards Supported

Analog Input - 4, 8 points

Yes

Yes

Analog Output - 2, 4 points

Yes

Yes

Low Level Analog Inputs - 4 points

Yes

Yes

Discrete Inputs - 4, 8, 16 points

Yes

Yes

Discrete Output - 4, 8, 16 points

Yes

Yes

High Speed Counter - 4, 8 points

Yes

Yes

Honeywell XMTR Interface Board

No

No

BBSTI Board - as justified

No

No

Check Before Operate

No

No

High Speed Analog

No

No

Содержание Bristol ControlWave CW_10

Страница 1: ...monly used analog discrete and counter I O cards as well as modems and radios currently installed in the RTUs Communication compatibility is maintained through the same use of BSAP and Modbus proto cols as were used in the 33XX Benefits The ControlWave architecture offers several ad vantages over existing 3310 3330 3335s including increased compatibility with industry standards such as IEC 61131 3...

Страница 2: ...with training to do the translation or you can rely on our Application Support Group to do the translation for you Specifications CW_10 CW_30 and CW_35 CPU 32 bit 150 MHz ARM processor Memory battery backup 7000 hours Optional one or two independent 10 100 Base T ports with RJ 45 connectors CW_30 and CW_35 only Ethernet port isolation 500 Vdc One 3 pin Utility Port for Flash downloading system fla...

Страница 3: ...50Hz to 2000Hz RFI Susceptibility 3V m 80 MHz to 1000Mhz EN50082 2 Power Consumption CPU without Ethernet 2 watt CPU with 1 Ethernet 3 watt CPU with 2 Ethernet 4 watt MFIB Watchdog off 1 watt MFIB Watchdog on 1 9 watt CW_XX 2 port comm 0 5 watt CW_XX 4 port comm 1 watt Hazardous Area Approvals FM approved as non incendive for operation in Class I Division 2 hazardous areas Ordering Information 331...

Страница 4: ...lity RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchas...