Installation, Operation and Maintenance Manual
VCIOM-15792-EN Rev. 0
Section 2: Installation
Installation
Figure 4
Positioning by chains and by slings
1.
Point of support
2.
Don’t lay the actuator on tie-rods of cylinder
3.
Don’t lay the actuator on accessories
(manual handpump, manual jackscrew, pneumatic control group etc.)
2.3 Storage
If the actuator needs storage, before installation follow these steps:
•
Place it on a wood surface in order not to deteriorate the area of valve coupling.
•
Make sure that plastic plugs are present on the hydraulic and electrical
connections (if present).
•
Check that the protection of the control system and of the limit switch box (if any)
are properly closed.
If the storage is long-term or outdoor:
•
Keep the actuator protected from direct weather conditions.
•
Replace plastic plugs of hydraulic and electrical connections (if any) with metal
plugs that guarantee perfect tightness.
•
Coat with oil, grease or protection disc, the valve coupling area.
•
Periodically operate the actuator, refer to Section 3.3.