![Emerson Bettis G01XXXX-M11 series Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/emerson/bettis-g01xxxx-m11-series/bettis-g01xxxx-m11-series_service-instructions-manual_102066007.webp)
Service Instructions
124843E Rev. C
August 2015
3
Section 1: Introduction
Introduction
1�4
Bettis Reference Materials
1.4.1
Assembly Drawing for G01-M11 through G10-M11 Double-Acting with one Pneumatic
Power Module and one Hydraulic Override Module use part number 115680.
1.4.2
M11 Manual Hydraulic Override System operating instructions part number
126858 with M11 Assembly Drawing part number 126567.
1.4.3
M11-S Manual Hydraulic Override System operating instructions part number
121962 with M11-S Assembly Drawing part number 121090.
NOTE:
If you require a specific assembly drawing (IE: GXX-M3 OR HYD) please contact Emerson
Actuation Technologies Bettis by phone or email at [email protected]
1�5
Service Support Items
1.5.1
Bettis module service kits.
1.5.2
For rod extension retainer nut tool part number, refer to the following table.
NOTE:
These tools are required only when extension rod assembly (1-50) or (9-50) is
removed or when a new extension rod assembly is installed.
Table 1�
G-Series Actuator Models
Actuator Model Bettis Part Number Actuator Model Bettis Part Number
G01
None required
G5/G7
117369
G2
123616
G8/G10
117368
G3/G4
117370
1.5.3
Commercial leak testing solution.
1.5.4
Non-hardening thread sealant.
1�6
Lubrication and Fluid Requirements
NOTE:
Lubricants and hydraulic fluids other than those listed in step 1.6.1 and 1.6.2 should not
be used without prior written approval of Bettis Product Engineering.
1.6.1
All temperature services (-50°F to +350°F)/(-45.5°C to 176.6°C) use Bettis ESL-5
lubricant. ESL-5 lubricant is contained in the Bettis module service kit in tubes or
cans and they are marked ESL-4, 5 and 10 lubricant.
1.6.2
FLUID REQUIREMENTS: M11 Manual Hydraulic Override System - All temperature
service (-20°F to +350°F)/(-28.9°C to 176.6°C) use Dexron II or Shell Tellus
T-32 Automatic Transmission Fluid. Low temperature service (-50°F to 150°F)/
(-45.5°C to 65.6°C) use Univis J13 or HVI 13 Hydraulic Fluid.