background image

8

U.L. Model No.: CF452

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1.

Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connectors supplied.

NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual
for wiring.

How to Wire Your Ceiling Fan

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before attempting
installation.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.

NOTE: CEILING COVER
OMITTED FOR CLARITY.

GROUND
WIRE

LISTED
WIRE
CONNECTOR (3)

GREEN WIRE
(GROUND) FROM
HANGER BRACKET

GREEN WIRE
(GROUND) FROM
HANGER BALL

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY
(HOT)

BLACK AND BLUE
FAN WIRES

Figure 4

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

Figure 13

WARNING

!

WARNING

!

2.

Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 13). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
13). After connections have been made, turn leads
upward and carefully push leads into the outlet box,
with the green equipment-grounding conductor and
white grounded neutral conductor on one side of
the outlet box and the black and blue ungrounded
conductors on the other side of the outlet box.

3.

Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.

4.

Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 14).

5.

Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 14).
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan
is now wired to be turned on and off from the fan
switch.

6.

Cut the 3-speed switch pull chain to a desired
length (optional). Connect the die-cast pendant
(supplied) to the 3-speed switch pull chain by
sliding the die-cast pendant (small hole first) onto
the pull chain. Attach the chain coupling to the end
of the chain and allow the die-cast pendant to fall
down over the coupling.

THREADED 
STUDS (2)

KNURLED 
KNOBS (2)

CEILING 
COVER

LOCKWASHERS 
(2)

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

Figure 14

WARNING

!

Содержание BELLA CF452GES

Страница 1: ...INSTRUCTIONS 52 Ceiling Fan Owner s Manual CF452AP00 Antique Pewter CF452AW00 Summer White CF452BS00 Brushed Steel CF452CK00 Chalk CF452GBZ00 Gilded Bronze CF452GES00 Golden Espresso CF452ORB00 Oil Rubbed Bronze CF452VNB00 Venetian Bronze Model Numbers BELLA Net Weight 20 50 Lbs ...

Страница 2: ...se the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 f...

Страница 3: ...ach step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not...

Страница 4: ...his time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by ...

Страница 5: ...stallation in Step 9 9 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Remove the upper setscrew from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 7 The clevis pin must go through the holes in the motor coupling and the holes in the...

Страница 6: ...wnrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 8 6 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling WARNING HAIRPIN CLIP CLEVIS PIN UPPER SETSCREW CLEVIS PIN SETSCREW HAIRPIN CLIP MOTOR...

Страница 7: ...OD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 12 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan coul...

Страница 8: ...g wire connector supplied Figure 13 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 13 After connections have been made turn leads upward and carefully push leads into the outlet box with the green equipment grounding conductor and white grounded neutral conductor on one side of the outlet box and the black and blue unground...

Страница 9: ...ing fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Maintenance Accessories Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock This product ...

Страница 10: ...d properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet 5 Tighten the hanger bracket screws to the outlet box is not securely fastened box and or secure out...

Страница 11: ...onnector 3 5 Pin Clevis 6 Clip Hairpin 7 Screw Flat Head M4 x 12mm 1 8 Screw Pan Head M6 x 14mm with Lockwasher 1 9 Screw Washer Head M5 x 6mm 16 10 Die cast Pendant 11 Threaded Stud 2 12 Lockwasher 2 13 Knurled Knob 2 14 Coupler Pendant 15 Balancing Kit 1 16 Canopy Ceiling 1 763785 AP 763785 AW 763785 BS 763785 CK 763785 GBZ 763785 GES 763785 ORB 763785 VNB 17 Wiring Harness 1 763912 2 763912 1 7...

Страница 12: ...horized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass g...