background image

13

emersonfans.com

Please contact 1-800-654-3545 for further assistance

U.L. Model No.: CF442

Ceiling fan performance and energy savings rely
heavily on the proper installation and use of the
ceiling fan. Here are a few tips to ensure quality and
product performance.

Choosing the Appropriate Mounting Location.

Ceiling fans should be installed, or mounted, in the
middle of the room and at least 7 feet above the floor
and 18 inches from the walls. If ceiling height allows,
install the fan 8 - 9 feet above the floor for optimal
airflow. Consult your Emerson Retailer for optional
mounting accessories.

10. Energy Efficient Use of Ceiling Fans

Using the Ceiling Fan Year Round.

In the summer,

use the ceiling fan in the counter-clockwise direction.
The airflow produced by the ceiling fan creates a wind-
chill effect, making you "feel" cooler. Select a fan speed
that provides a comfortable breeze, lower speeds
consume less energy. In the winter, reverse the motor
and operate the ceiling fan at low speed in the
clockwise direction. This produces a gentle updraft,
which forces warm air near the ceiling down into the
occupied space. Remember to adjust your thermostat
when using your ceiling fan - additional energy and
dollar savings could be realized with this simple step! 

Turn Off When Not in the Room. 

Ceiling fans cool

people, not rooms. If the room is unoccupied, turn off
the ceiling fan to save energy.

Содержание BELLA CF442AW

Страница 1: ...LA 42 Ceiling Fan Owner s Manual Model Numbers CF442AW00 Summer White CF442ORB00 Oil Rubbed Bronze CF442SW00 Satin White Net Weight 16 9 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com ...

Страница 2: ...eiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories desi...

Страница 3: ...keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A E B D F G H C PACKAGE CONTENTS 4 1 2 3 5...

Страница 4: ...rsonal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work no...

Страница 5: ... SWITCH HOUSING ADAPTER REMOVE AND DISCARD THE FIVE SHIPPING SPACERS AND SCREWS FROM THE MOTOR HUB Figure 1 BLADE FLANGE M5 x 6mm WASHER HEAD BLADE SCREW 3 per blade flange FAN BLADE Figure 2 MOTOR HUB BLADE FLANGE ASSEMBLY MOTOR HUB NOTCHED AREA M6 x 14mm CAPTIVE PAN HEAD SCREW 2 per blade flange assembly Figure 3 To reduce the risk of personal injury do not bend the blade flange when installing ...

Страница 6: ...he connector latch closes properly 6 Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three M4 x 12mm flat head screws supplied Figure 5 SWITCH HOUSING MOUNTING SCREW 3 SWITCH HOUSING ASSEMBLY SWITCH HOUSING CONNECTOR MOTOR CONNECTOR Figure 4 M4 x 12mm...

Страница 7: ...of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Reinstall the upper setscrew in the motor coupling Check that the lower setscrew is tightened securely Figure 7 NOTE The setscrews must be properly installed as described above or fan wobble co...

Страница 8: ...comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 13 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan 3 Ceiling Fan Assembly continued CEILING COVER HANGE...

Страница 9: ...he risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance ...

Страница 10: ...onductor and white grounded neutral conductor on one side of the outlet box and the black and blue ungrounded conductors on the other side of the outlet box 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 14 Check to see that all connecti...

Страница 11: ...use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING REVERSIBLE SWITCH SPEED CONTROL SWITCH IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasi...

Страница 12: ...nectors in switch housing are not rattling against each other or against the interior wall of the switch housing 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrew in motor coupler is loose 1 Tighten both setscrews securely in the motor coupling excessively 2 Setscrew in the hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downr...

Страница 13: ...s 10 Energy Efficient Use of Ceiling Fans Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in th...

Страница 14: ...14 U L Model No CF442 11 Repair Parts 20 6 5 9 13 12 19 16 10 14 17 18 21 11 1 2 3 15 7 8 4 ...

Страница 15: ...1 761655 32 761655 92 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod 4 5 Parts Bag Containing 763913 1 763913 763913 1 4 Wire Connector 3 5 Pin Clevis 1 6 Clip Hairpin 1 7 Screw Flat Head M4 x 12mm 1 8 Screw Pan Head M6 x 14mm with Lockwasher 1 9 Screw Washer Head M5 x 6mm 16 10 Die Cast Pendant 1 11 Threaded Stud 2 12 Lockwasher 2 13 Knurled Knob 2 14 Coupler Pendant 1 15 Blade Balance Ki...

Страница 16: ...16 U L Model No CF442 Notes ...

Страница 17: ...17 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF442 Notes ...

Страница 18: ...18 U L Model No CF442 Notes ...

Страница 19: ... can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Servi...

Страница 20: ...Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74020003 Form No BP7402 3 Revision 131015 U L Model No CF442 Printed in China 10 13 ...

Отзывы: