background image

6

YELLOW 
FAN WIRE

ONE-PIN 
CONNECTOR

LIGHT KIT 
ASSEMBLY

WHITE LIGHT KIT 
ASSEMBLY WIRE

WHITE FAN WIRE

YELLOW LIGHT KIT 
ASSEMBLY WIRE

Figure 8

15-WATT 
CANDELABRA 
BASE LIGHT 
BULB (4)

LIGHT KIT 
ASSEMBLY 
SOCKET (4)

Figure 9

15.

Securely connect the white fan one-pin connector
wire to the white one-pin connector wire from the
light kit assembly. Connect the yellow fan one-pin
connector wire to the yellow light kit assembly
one-pin connector wire (Figure 8).

16.

Install four 15-watt candelabra base light bulbs in
the light kit assembly sockets (Figure 9).

17.

Unscrew and save one of the three screws in the
light kit adapter. Position the light kit assembly
onto the light kit adapter, making sure the wires
are positioned through a notched hole before
securing (Figure 10).

18.

Rotate the light kit assembly so that the two
screws engage in the keyholes slots. Secure the
light kit assembly to the light kit adapter by
threading the previously removed screw into the
remaining hole. Tighten the three screws
securely at this time. (Figure 10). 

NOTE: Do not pinch wires between the light kit
assembly and the light kit adapter.

LIGHT KIT 
ASSEMBLY 
SCREW (3)

LIGHT KIT 
ASSEMBLY

KEYHOLE 
SLOTS

NOTCHED 
HOLE

NOTCHED 
HOLE

Figure 10

19.

Obtain the hanger ball/downrod assembly and
remove the hanger ball by loosening the
setscrew in the hanger ball until the ball falls
freely down the downrod (Figure 11). Remove
the pin from the downrod, then remove the
hanger ball. Retain the pin and hanger ball for
reinstallation in Step 27. Discard the 12” downrod
if using the 6” downrod.

NOTE: The longer downrod (12”) furnished with
the ceiling fan provides the minimum
recommended floor-to-fan blade clearance for a
9-foot ceiling. The 6” downrod (supplied) is to be
used for shorter ceilings.

20.

Separate, untwist and unkink the black, white and
blue motor wires and the yellow uplight lead.
Route these wires through the downrod.

21.

Fold the wires from the downrod into the slot in
the motor coupling. Then slide the downrod down
the wires and seat the downrod in the motor
coupling (Figure 12).

22.

Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 12). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Push the
straight leg of the hairpin clip through the hole
near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose.

HANGER BALL

PIN

DOWNROD

SETSCREW

Figure 11

U.L. Model No.: CF3200

U.L. Model No.: CF3200

Содержание BATON ROUGE CF3200AWL00

Страница 1: ...SE INSTRUCTIONS Part No F40BP73500000 Form No BP7350 U L Model No CF3200 Net Weight 26 0 Lbs Model Numbers BATON ROUGE Ceiling Fan Owner s Manual CF3200AWL00 Summer White w Latte Highlights CF3200DBZ00 Distressed Bronze ...

Страница 2: ...or fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod 12 furnished with the ceiling fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The 6 downrod supplied is to be used for shorter ceilings 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with th fa...

Страница 3: ...545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING WARNING 1 Open styrofoam unit containing fan Remove upper and ce...

Страница 4: ...rical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan...

Страница 5: ...SWITCH HOUSING WHITE WIRE Figure 3 ALL WIRES AND CONNECTORS LOCATION SWITCH HOUSING PLATE NOTCHED HOLE SWITCH HOUSING Figure 4 8 32 x 10mm FLAT HEAD SCREW 3 SWITCH HOUSING Figure 5 PARTIALLY ASSEMBLED CEILING FAN STYROFOAM Figure 6 DECORATIVE LIGHT KIT RING LIGHT KIT GLASS LIGHT KIT GLASS RUBBER CLIP 3 RUBBER CLIP SCREW Figure 7 12 Carefully turn over the partially assembled ceiling fan and place ...

Страница 6: ...tain the hanger ball downrod assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 11 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 27 Discard the 12 downrod if using the 6 downrod NOTE The longer downrod 12 furnished with the ceiling fan provides t...

Страница 7: ...ure the cover to the motor All wires and wire connectors must be enclosed under the motor cover Figure15 NOTE Lightly snug the knurled knob and make sure the wires and wire connectors are completely inside the motor coupling cover and not pinched between the motor coupling cover and the motor IMPORTANT A If you have installed the 12 or optional longer downrod and are planning to install the decora...

Страница 8: ...VER 12 DOWNROD OR LONGER MOTOR COUPLING COVER Figure 17 SCROLL COLLAR DECORATIVE SCROLL ASSEMBLY 4 SCROLL COLLAR SCREWS 4 Figure 18 3 Slide the assembled decorative scroll over the 12 downrod and position each scroll leg on the decorative light kit ring Figure 19 Secure each of the four decorative scroll legs using four 8 32 x 15mm flat head screws supplied ASSEMBLED DECORATIVE SCROLL 8 32 x 15mm ...

Страница 9: ...main fuse or circuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician CAUTION To reduce the risk of electrical shock disconn...

Страница 10: ...y 1 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 25 2 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 26 3 Secure the ceiling cover in place by installing two lockwashers and two knurled knobs supplied Figure 26 Tighten the knurled knobs securely until the ceiling cover fit...

Страница 11: ...Wall Control and Receiver Figure 27 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small scre...

Страница 12: ...has been tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference...

Страница 13: ... brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Accessories 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog Do not use water when cleaning your ceiling fan It could damage the motor or the blades and creat...

Страница 14: ...8 7 8 33 34 17 19 20 22 23 28 13 14 15 16 BLADE 10 32 x 10mm PAN HEAD SCREW 4 Per Blade FLANGE ASSEMBLY FLANGE MEDALLION 26 24 21 12 25 27 29 30 HI HI MED MED LOW LOW FAN OFF REV REV LIGHT 34 Repair Parts U L Model No CF3200 U L Model No CF3200 ...

Страница 15: ...453 AW 763453 DBZ 23 Glass Upper 1 763452 1 763452 24 Flange Assembly 5 per set 763455 AWL 763455 DBZ 25 Flange Medallion Assembly 5 per set 763457 AWL 763457 DBZ 26 Blade Assembly 5 per set 763459 1 763459 27 Harness Wiring 1 763496 763496 28 Housing Switch 1 763462 AWL 763462 DBZ 29 Receiver Remote Control SW105 1 762401 762401 30 Transmitter Remote Control SW116 1 763310 763310 31 Downrod Short...

Страница 16: ... an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The ...