k. One loose parts bag containing:

1. Two 1-1/4” threaded studs
2. Two knurled knobs
3. Two lockwashers
4. Three wire connectors
5. One clevis pin
6. One hairpin clip
7. Eleven M5 x 16mm oval

head screws

8. Sixteen M5 x 6mm slotted

Phillips washer head screws

NOTE: Place the parts from the loose
parts bags in a small container to keep
them from being lost. 

2. Remove the fan motor and housing

uplight assembly from the protective
plastic bag. Place the fan motor and
housing uplight assembly on a padded
work surface with the bottom of the
motor facing up.

IMPORTANT: Remove the two card-
board retainers from between the
housing uplight and the motor
housing.

E

F

G

I

B

C

K

EMERSON

®

HI

MED

LOW

FAN  OFF

LIGHT

ON

OFF

J

H

A

D

Your new ceiling fan will require a
grounded electrical supply line of 120 volts
AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored
and capable of withstanding a load of at
least 50 pounds.

To reduce the risk of fire, electric shock,
or personal injury, mount fan to outlet box
marked “Acceptable for Fan Support”,
and use screws supplied with outlet box.
Most outlet boxes commonly used for
support of light fixtures are not
acceptable for fan support and may need
to be replaced. Consult a qualified
electrician if in doubt.

!

WARNING

If your fan is to replace an existing ceiling
light fixture, turn electricity off at the main
fuse or circuit breaker box at this time and
remove the existing light fixture.

Electrical Requirements

Turning off wall switch is not sufficient.
To avoid possible electrical shock, be
sure electricity is turned off at the main
fuse or circuit breaker box before wiring.
All wiring must be in accordance with
National and Local codes and the ceiling
fan must be properly grounded as a
precaution against possible electrical
shock.

!

WARNING

IMPORTANT: Your ceiling fan will not
function properly, and may be
damaged, if used with any wall dimmer
switch or control other than the
Emerson Electric SW101 Fan/Light Wall
Control supplied with the fan, or an
optional Emerson Electric SR100
Remote Control.

BP7309 BANFF  1/5/06  9:59 AM  Page 4

Содержание BANFF CF720ORB00

Страница 1: ... determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV ...

Страница 2: ...nd use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 5 Follow the recommended instructions for the pr...

Страница 3: ...ith ground of the following sizes Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Before assembling your ceiling fan refer to section on proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to...

Страница 4: ... fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING If your fan is to replace an existing ceiling light fixture turn electricity off at t...

Страница 5: ...ircuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blad...

Страница 6: ... must be properly installed to prevent the clevis pin from working loose Pull up on the downrod to make sure the clevis pin is properly installed WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed as shown in Figure 4 could result in the fan falling 3 Careful...

Страница 7: ...pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble SETSCREW DOWNROD CEILING CANOPY HANGER BALL PIN How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 7 WARNING CEILING FLOOR AT LEAST 7 Figure 7 11 The fan comes with blue black and white leads that are 80 long Before installing the fan measure up ...

Страница 8: ...WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 8 Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING NOTE CEILING COVER SUPPL Y WIRES AND FAN WIRES OMITTED FOR CLARITY OUTLET BOX HANGER BR...

Страница 9: ...receiver white AC IN N wire Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING c Securely connect the supply black wire hot wire to the receiver black AC IN L wire d Securely connect the fan motor white wire to the recei...

Страница 10: ...d studs and turn until the studs protrude through the holes in the ceiling canopy Figure 12 6 Secure the ceiling canopy in place by sliding lockwashers supplied over the threaded studs and installing the two knurled knobs supplied Figure 12 Tighten the knurled knobs securely until the ceiling canopy fits snugly against the ceiling 1 1 4 THREADED STUD 2 CEILING CANOPY KNURLED KNOB 2 LOCKWASHER 2 Fi...

Страница 11: ... Ceiling Fan IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the remote control Your Fan Light Wall Control Figure 15 has full control of your fan and lights However airflow direction is controlled by a slide switch on the switch housing 1 Restore electrical power to the outlet box by turning the electricity on at the service panel NOTE M...

Страница 12: ...cessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not requir...

Страница 13: ...Loose screws in motor housing 4 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling are 1 Tighten setscrews securely excessively not tightened securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blade 3 Check to be sure screws which flanges to...

Страница 14: ... be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 14 BP7309 BANFF 1 5 06 9 59 AM Page 14 ...

Страница 15: ...ps Washer Head M5 x 6mm 16 11 Screw Oval Head M5 x 16mm 11 12 Ceiling Canopy 763070 ORB 763070 PW 763070 WB 13 Upper Glass 763071 763071 1 763071 14 Flange Assembly set of 5 763080 ORB 763080 PW 763080 WB 15 Lower Glass 763073 763073 1 763073 16 Wall Control SW101 17 Harness 763084 763084 763084 18 Housing Uplight Assembly 763072 ORB 763072 PW 763072 WB 19 Housing Downlight Assembly 763074 ORB 763...

Страница 16: ...o our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not auth...

Отзывы: