background image

3

ETL Model No.: CF921

EMERSON QUICK START GUIDE

The Quick Start Guide covers the installation
instructions common for ceiling fan operations. If
additional assistance with wiring, alternate hanging
systems, or lighting options, proceed to the complete
instructions of this Owner’s Manual.

The Quick Start Guide sections include page numbers
to correspond with the appropriate sections of the
Owner’s Manual for detailed instructions.

*

See Unpacking Instructions for a complete list of
parts for installation. 

Installation of Downrod (page 6)

1.

Remove the hanger ball from
the downrod.

2.

Install the downrod to the
motor coupling using the
clevis pin and hairpin clip.

3.

Tighten the setscrews.

1.

Disconnect electrical power to
the branch circuit at the
circuit breaker or fuse box
before attempting to install
the ceiling fan hanger bracket
on the outlet box.

AT LEAST

7'

CEILING

FLOOR

2.

The fan must be hung with at
least 7’ of clearance from
floor to blades.

3.

Attach the hanger bracket to
the outlet box.

4.

Seat the hanger ball/downrod
assembly on the hanger
bracket.

Hanging Your Ceiling Fan (page 9)

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable for Fan
Support of 22.7 kg. (50 lbs.) or less”, and use screws
supplied with outlet box. Most outlet boxes commonly used
for support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a qualified
electrician if in doubt.

!

WARNING

Installation of Blade Assembly (page 7) 

1.

Mount blade flanges to fan
blades (sold separately) using
four #10-24 x 12mm washer
head blade screws.

2.

Loosely attach one blade
assembly to the motor hub
using two 1/4-20 x 14mm
captive screws with lock-
washers. Make sure the
screws are NOT tightened.
Repeat this procedure for
other four blade assemblies.

Installation of Switch Housing (page 8)

1.

Remove the four switch
housing mounting screws
from the switch housing
plate. Position the switch
housing assembly on the
switch housing plate and
align the holes in the switch
housing assembly with the
holes in the plate. Secure the
switch housing assembly by
installing the four screws.

Installation of Ceiling Fan (page 7)

1.

Install the coupler cover and
ceiling cover onto the
downrod.

2.

Reinstall the hanger ball onto
the downrod, place the pin
into the hanger ball and
tighten the setscrew.

Turning off wall switch is not sufficient. To avoid possible electrical
shock, be sure electricity is turned off at the main fuse or circuit
breaker box before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical shock.

!

WARNING

NOTE: Tuck in both the blue and white wires carefully under the
switch housing cover

Содержание AVANT ECO CF921VNB00

Страница 1: ...EAD AND SAVE THESE INSTRUCTIONS Ceiling Fan Owner s Manual CF921BS00 Brushed Steel CF921CK00 Chalk CF921GES00 Golden Espresso CF921ORB00 Oil Rubbed Bronze CF921VNB00 Venetian Bronze Model Numbers AVANT ECO Net Weight 16 6 Lbs 54 60 or 72 Fan Blades Not Included ...

Страница 2: ...rt and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ce...

Страница 3: ...ox Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Installation of Blade Assembly page 7 1 Mount blade flanges to fan blades sold separately using four 10 24 x 12mm washer head blade screws 2 Loosely attach one blade assembly to the motor hub using two 1 4 20 x 14mm capt...

Страница 4: ...ct wires with wire connectors supplied NOTE If you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Securely connect the fan motor black wire to the supply black hot wire using wire connector supplied 3 After connections have been made turn leads up...

Страница 5: ...your ceiling fan refer to section on proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specif...

Страница 6: ... may need to be replaced Consult a qualified electrician if in doubt WARNING 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 4 2 Separate untwist and unkink the two 80 motor leads Route the motor lead wires...

Страница 7: ...back insulation 1 2 inch from end of leads 6 Carefully turn the partially assembled ceiling fan over and set it on the shipping styrofoam for blade installation 7 Remove the shipping spacers and the spacer attachment screws from the motor before installation of blade assemblies Discard the spacers and spacer screws Figure 4 8 Mount blade flanges to fan blades sold separately using four 10 24 x 12m...

Страница 8: ...s Figure 7 NOTE Tuck in both the blue and white wires carefully under the switch housing cover 12 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan How to Put Your Ceiling Fan Together continued To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan ...

Страница 9: ... BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 10 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not secu...

Страница 10: ...tact a licensed electrician for advice as it must be grounded for safe operation NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE Check to see that all connections are tight including ground and that no bare wire is visible at the wi...

Страница 11: ...switch is turned OFF the control will remember the light intensity and fan speed When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 13 2 Install two AAA alkaline batteries and reinstall the battery cover Setting Operatin...

Страница 12: ...To vary the intensity of the light hold the DN or UP button down until the desired light intensity is reached then release the button 6 The sixth switch marked ON and I is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to I for no dimming of the lights such as for fluorescent bulbs Installation of Storage Bracket for SR600 Remote Control A storage brac...

Страница 13: ...of installation 3 Install the light kit assembly to the motor assembly using three light kit assembly mounting screws Figure 17 4 Securely connect the light kit assembly connector to the motor assembly connector Figure 18 5 Screw the four 25 watt candelabra base bulbs supplied into the light kit assembly sockets Figure 18 6 Carefully tuck all wiring and wire connectors close to the downrod and sli...

Страница 14: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation ...

Страница 15: ...re loose the fan flanges to the motor hub are tight 4 Wire connectors inside switch housing 4 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling ...

Страница 16: ...16 Repair Parts 6 BLADES SOLD SEPARATELY 17 21 16 4 7 1 2 3 9 8 5 20 14 18 13 19 11 15 12 10 ETL Model No CF921 ...

Страница 17: ... 32 x 8mm 1 15 Balancing Kit 1 16 Canopy Ceiling 1 761620 BS 761620 CK 761620 GES 761620 ORB 761620 VNB 17 Motor Coupling Cover 1 764118 BS 764118 CK 764118 GES 764118 ORB 764118 VNB 18 Switch Housing 1 764116 BS 764116 CK 764116 GES 764116 ORB 764116 VNB 19 Flange Assembly set of 5 764134 BS 764134 CK 764134 GES 764134 ORB 764134 VNB 20 Motor Control Receiver 764125 764125 764125 764125 764125 21...

Страница 18: ...18 ETL Model No CF921 Notes ...

Страница 19: ...19 ETL Model No CF921 Notes ...

Страница 20: ...horized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass g...