LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling
fan against all defects in workmanship and materials. You must be the original purchaser or user of the product
to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for 10 years from the date you purchased your ceiling fan.
All other components and accessories are covered by this warranty for one year from the date you purchased
your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other
accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable
time and no replacement can be provided, Emerson Electric Co. will refund the actual purchase price of your fan.
We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or
removal, reinstallation and shipping of the product to Emerson Electric Co.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY
SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory
or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to

Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136.
Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest

authorized service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized
service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit
since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does
not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal

wear and tear.

• Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are

voided when:

• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other
written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any
warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS
WARRANTY AND EMERSON ELECTRIC CO. IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING
INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such
damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of
repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above
exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.

Содержание ATOMICAL CF930BS01

Страница 1: ...1 1 1 1 1 ...

Страница 2: ...YL ...

Страница 3: ...Supplied l Two 60 watt candelabra bulbs ...

Страница 4: ...k l ...

Страница 5: ... with any wall dimmer switch or control other than the Emerson Electric Fan Light Wall Control supplied with the fan or an optional Emerson Electric SR100 Remote Control Electrical Requirements Ceiling Fan Procedures IMPORTANT Before assembling your ceiling fan refer to sections Setting Operating Frequency of Wall Control and Receiver and Installation of Wall Control Page 12 These sections instruc...

Страница 6: ...t the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed PIN HANGER BALL SETSCREW DOWNROD Figure 1 SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP DOWNROD HAIRPIN CLIP MOTOR COUPLING SETSCREW 2 CLEVIS PIN Figure 2 HAIRPIN CLIP CLEVIS PIN MOTOR COUPLING COUPLER COVER CEILING CANOPY SETSCREW 2 Figure 3 It is critical that the clevis pin in the...

Страница 7: ......

Страница 8: ......

Страница 9: ...g connections using wire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 2 Refer to Figures 13 and 14 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the sup...

Страница 10: ...wire Do not operate fan until blades are in place Noise and fan damage could result WARNING e Securely connect the fan motor black wire to the receiver red TO MOTOR L wire f Securely connect the fan motor blue wire to the receiver blue FOR LIGHT wire GREEN GROUND WIRE FROM HANGER BRACKET RECEIVER RED WIRE RECEIVER WHITE WIRE FAN WHITE WIRE FAN BLACK WIRE ANTENNA AC IN N AC IN L F O R L IG H T T O ...

Страница 11: ......

Страница 12: ...tings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 In the receiver slide the four switch levers to the same positions as set in the wall control Make sure the levers on both switches are in the same positions otherwise the fan will not operate WALL CONTROL L...

Страница 13: ...t any neutral white wire to this control Incorrect wiring will damage this control WARNING EMERSON HI MED LOW FAN OFF LIGHT ON OFF BLACK BLK HOT FAN LIGHT WALL CONTROL WALL BOX TO LOAD TO 120VAC SOURCE G R OUND Figure 20 3 WAY INSTALLATION On fan controlled by two different wall controls See Figures 21 and 22 1 Disconnect power at circuit breaker or remove fuse 2 At all wall box locations remove f...

Страница 14: ... ON position 2 To set the desired fan speed press the HI MED or LOW buttons to operate your fan on high medium or low speed Figure 23 3 To turn your fan off press the OFF button 4 To set the level of light brightness press and hold the LIGHT button The light brightness will continue to increase then decrease while the button is held down When the light is at the desired brightness release the butt...

Страница 15: ...y those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan ...

Страница 16: ......

Страница 17: ... 1 1 1 762670 5 762670 5 762670 5 ...

Страница 18: ...housing 3 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling are 1 Raise coupling cover and tighten excessively not tightened securely setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blades 3 Check to be sure screws which to mot...

Страница 19: ...st authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warra...

Страница 20: ... 1 1 ...

Отзывы: