Field Conversion Kits for Series 300 Transfer Switches

Fig. 10:

Programmable Engine Exerciser

with Source Availability Contacts

(Accessory 11BG)

Fig. 11:

Strip Heater Kit

(Accessory 44G)

Series 300 ATS

Optional Accessories

Fig. 12:

Pulsar 450 

Surge Suppressor

Accessory 11BG

A programmable engine exerciser that provides for weekly or
biweekly operation, includes one form C contact for source
availability of normal and one contact for availability of emergency
(contact rating 2 amps @ 30 Vdc, 0.5 amp @ 125 Vac resistive).
The programmable engine exerciser incorporates a 7 day or 14 day
time base with a digital readout display. Includes “with or without”
load control switch for exerciser period.

Accessory 14AA/14BA

Auxiliary contacts to indicate position of main contacts.Two (2) for
normal and two (2) for emergency position (one set is standard).

Accessory 44A

Strip Heater with thermostat for extremely cold areas to prevent
condensation and freezing of this condensation. External 120 volt
power source required.

Accessory 44G

Strip Heater with thermostat, wired to load terminals: 208-240, 
360-380, 460-480, 550-600 volts. Contains wiring harnesses for 
all transfer switch sizes.

Accessory 72A

Communications Interface Module (RS-485) to allow local or
remote communications with ASCO Power

Quest

®

VP

i

or

Site

Web™

communication products.

ASCO Pulsar

fi

450 

High-Performance Surge Suppressor

The ASCO Pulsar

fi

450 provides unparalleled protection from power

surges and transients. It is a high-performance surge suppressor
which limits large surges and transients through a unique array of
computer-matched metal oxide varistors (MOVs). Unique four-
cavity sand packed UL94-5 volt rated housing, UL1449, UL1283,
and CSA listed. Available as a separate product only for mounting
by customer. Contact ASCO for ordering information.

8

+

+

+

+

+

+

+

B

300

600

3

N

1

X

C

+

+ 480 V 60 Hz

2 poles,

1

3 poles,

3

A

3

B

3

C
D
E
F
H
J
K
L
M
N
Q
R

1

Insert X

If optional

accessories 

are required

Continuous

rating

30, 70, 104,

150, 200, 
230, 260,

400, 600

4

,

800

4

, 1000

4

,

1200

4

, 1600,

2000

2600

4

, 3000

4

Type 1

(Standard)

Type 3R

Enclosure

Type 4

Enclosure

2

Type 12

Enclosure

2

Type 3R

Secure

Enclosure

Product

Blank

Solid

Neutral

B

1

Switched

Neutral

Neutral

Code

Poles

Amperes

Voltage

Code

Controller

11BG

Programmable

Engine Exerciser

14AA/14BA

Auxiliary Contacts

(2 sets)

44A, 44G

Strip Heater

w/Thermostat

72A Comm

Interface Module

Optional

Accessories

This information 

is necessary 

to allow correct 
control settings

prior to shipment

Specific 

Volt & Freq

Options

Enclosure

Blank Open Type

C

F

G

L

M

C

F

G

L

M

11CD

+

+

+

+

+

+

+

386

B

386

600

3

N

1

X

C

+

+ 480 V 60 Hz

2 poles,

1

3 poles,

3

Continuous

rating

30, 70, 100,

150, 200,

230 260,

400, 600

4

,

800

4

, 1000

4

,

1200

4

, 1600,

2000, 3000

4

Type 1

(Standard)

Type 3R

Enclosure

Type 4

Enclosure

2

Type 12

Enclosure

2

Type 3R

Secure

Enclosure

Product

A

Solid

Neutral

B

1

Switched

Neutral

Neutral

Code

Phase

Poles

Amperes

Enclosure

Blank Open Type

9C/9D

To order an ASCO Series 386 Transfer Switch, complete the following catalog number:

6Q

Key-Operated 

Control 

9C/9D

Source 

Availability Lights

14AA/14BA

Auxiliary Contacts

72A Comm

Interface Module

All Accessories

Optional

Accessories

To order an ASCO Series 300 Power Transfer Switch, complete the following catalog number:

This information 

is necessary 

to allow correct 
control settings

prior to shipment

Specific 

Volt & Freq

Extended Warranties for Series 300 Transfer Switches

115
120
208
220
230
240
380
400
415
440
460
480
575
600

A

3

B

3

C
D
E
F
H
J
K
L
M
N
Q
R

Voltage

Code

115
120
208
220
230
240
380
400
415
440
460
480
575
600

1

Insert X

If optional

accessories 

are required

Controller Options

Ordering Information for            

Series 300 & 386

Transfer Switches

Catalog No.

Description

2EXW300

Two-Year Extended Warranty (Parts & Labor)

3EXW300

Three-Year Extended Warranty (Parts & Labor)

4EXW300

Four-Year Extended Warranty (Parts & Labor)

5EXW300

Five-Year Extended Warranty (Parts & Labor)

9

UL Type 1 Enclosure

(See notes below for information on Type 3R, 4 & 12 Enclosures)

Switch Rating

amps

Phase 

Poles

Neutral 

Code

Dimensions, In. (mm)3

Width

Height

Depth

Approx. Shipping

Weight Lb. (kg)4

2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
3
3
3
3

30, 70, 100*, 104

150, 200

230, 260, 400

600, 800, 1000

1200

1600, 2000

1,6

2600, 3000

2

A
B
A
B
A

B

7

or C
A

B

7

or C
A
B
A
B
A
B
A
B
A
B
A
B

17 1/2 (445)
17 1/2 (445)
17 1/2 (445)
17 1/2 (445)

18 (457)
18 (457)
18 (457)
18 (457)
34 (864)
34 (864)
34 (864)
34 (864)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)

31 (787)
31 (787)
31 (787)
31 (787)

48 (1219)
48 (1219)
48 (1219)
48 (1219)
72 (1829)
72 (1829)
72 (1829)
72 (1829)
87 (2210)
87 (2210)
87 (2210)
87 (2210)
87 (2210)
87 (2210)
91 (2311)
91 (2311)

11 5/8 (295)
11 5/8 (295)
11 5/8 (295)
11 5/8 (295)

13 (330)
13 (330)
13 (330)
13 (330)
20 (508)
20 (508)
20 (508)
20 (508)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)
24 (610)

60 (1524)
60 (1524)

Series 300 & 386 External Power Connections

Sizes UL-Listed Solderless Screw-Type Terminals  

Switch Rating

(amps)

Ranges of AL-CU Wire Sizes

(Unless Specified Copper Only)

Dimensions & Shipping Weights for

Series 300 & 386

Transfer Switches

Note: 

All Series 300 switches are furnished with a solid neutral plate 

(unless switched neutral configuration is specified) and terminal lugs. 
Specify  A in catalog number to order a neutral plate on the series 
386 switches.

*

200 and 230 amp rated switches for use with copper cable only. 

*series 386 only

10

300

One #14 to 4/0 AWG

Two 1/0 AWG to 250 MCM

or One #4 AWG to 600 MCM

Two 1/0 AWG to 600 MCM

Four 1/0 to 600 MCM

Six 1/0 to 600 MCM

Twelve 3/0 to 600 MCM
Twelve 3/0 to 600 MCM

30 - 230*

260, 400

600

800, 1000, 1200

1600, 2000

2600
3000

Kit No.

Description

K629830                       Engine Exerciser and source availability contacts (Acc. 11BG)
K613127-001

Strip Heater Kit (125 watt) 120 volt (Acc. 44A)

K613127-002

Strip Heater Kit (125 watt) 208-480 volt (Acc. 44G)

K609027

Cable Pull Box (1600-2000 amp)

K473872-001

6 FT Extension Harness*

* For 30-200 Amp switches only, not available for 300SE

Note:

1. Specify neutral code  C for 260 and 400 amperes only. 
2. Available 30-1000, and 1600 amps. Use Type 3R for 1200, 2000, 2600 and 3000 amp applications.
3. 115-120 volt available 30-400 amps only. For other voltages contact ASCO.
4. 600-1200 amp only available in secure type 3R enclosure.  Secure type provided as standard for 2600-3000 amp.

69 (32)
73 (33)
73 (33)
75 (34)

100 (45)
110 (50)
100 (50)
120 (55)

450 (204)
475 (217)
475 (217)
500 (228)
685 (312)
705 (321)
705 (321)
725 (328)
925 (419)
975 (441)

1700 (771)
2135 (969)

Notes:

1. Unit is designed for top cable entry of emergency & load

and bottom entry of normal. A cable pull box is also avail-
able for all top or bottom cable access when required
(optional accessory kit #K609027). Not required for type
3R, 4 & 12 enclosures where available.

2. Enclosures for 2600, 3000 amps are free-standing with

removable top, sides & back.

3.  For type 3R, 4 & 12 dimensions, add the following 

values to the type 1 dimensions:
a) 30, 70, 100, 104, 150, 200A–add 1.5 in (38 mm) to the

height.

b) 230, 260, 400A - add 1.5 in (38 mm) to the depth.
c) 1200A–type 4 & 12 not available–use 1600 amp switch
d) 1600A–add 3 in (76 mm) to the height and 10 in to 

(253 mm) to the width.

e) 2000, 2600, 3000A–type 4 & 12 not available. 

(Consult ASCO) Type 3R add 4.68 in (118 mm) to the
height add 2.0 in (51 mm) to the width and add 13 in
(329 mm) to the depth.

4. For type 3R, 4 & 12 weights, add the following values to

the type 1 weights:
a) 30, 70, 100, 104, 150, 200A–add 15 lbs. (6.8 kg).
b) 230, 260, 400, 600, 800, 1000A–add 40 lbs. (18.1 kg).
c) 1600A–add 60 lbs. (27 kg).
d) 2000A–3000A Type 4 & 12 not available. (Consult ASCO)

5. When temperatures below 32ºF can be experienced,

special precautions should be taken, such as the inclusion
of space heaters, to prevent condensation and freezing
of this condensation. This is particularly important when
environmental enclosures (Type 3R, 4 & 12) are ordered
for installation outdoors.

6. Front connected design for 300 only, 

386 dimensions are: 38"W - 91"H - 48"D.

7. Neutral Code “B” for 230 ampares only.

Содержание ASCO 300 Series

Страница 1: ...mprehensive maintenance agreements that detail the preventive care needed to keep emergency power systems ready to respond A service agreement is an effective way to budget in advance and avoid unexpected expenditures A 35 point checklist is utilized to assure critical systems and components are kept in top operating condition These preventive programs can be customized for national accounts This ...

Страница 2: ...needs of the community When time is a critical factor such as when responding to a fire alarm or an emergency call an ASCO Series 300 Transfer Switch can be a lifesaver switching power to the backup generator While not all municipal services are a matter of life and death they are always expected to be there Agriculture Maintaining electrical power is vital to an agriculture operation If the flow ...

Страница 3: ...needs of the community When time is a critical factor such as when responding to a fire alarm or an emergency call an ASCO Series 300 Transfer Switch can be a lifesaver switching power to the backup generator While not all municipal services are a matter of life and death they are always expected to be there Agriculture Maintaining electrical power is vital to an agriculture operation If the flow ...

Страница 4: ...rd C22 2 for automatic transfer switches l Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code NEC Articles 700 701 and 702 l 30 through 3000 amps in a compact design l Available to 600 VAC single or three phase l True double throw operation The single solenoid design is inherently interlocked and prevents contacts from stopping between sources or from being in ...

Страница 5: ...rd C22 2 for automatic transfer switches l Meets NFPA 110 for Emergency and Standby Power Systems and the National Electrical Code NEC Articles 700 701 and 702 l 30 through 3000 amps in a compact design l Available to 600 VAC single or three phase l True double throw operation The single solenoid design is inherently interlocked and prevents contacts from stopping between sources or from being in ...

Страница 6: ...sary to allow correct control settings prior to shipment Specific Volt Freq Options Enclosure Blank Open Type C M N Q 11CD 115 120 208 220 230 240 380 400 415 440 460 480 575 600 To order an ASCO Series 300SE Power Transfer Switch complete the following catalog number Dimensions Shipping Weights for Series 300SE Transfer Switches Ordering Information for Series 300SE Transfer Switches UL Type 1 En...

Страница 7: ...cations interface module RS 485 to allow local or remote communications with ASCO PowerQuest VPi or SiteWeb communication products l Special Enclosures Specify by appropriate code in catalog number Type 3R Raintight Type 4 Weatherproof Type 12 Oil Tight User Initiated Control ASCO 386 non automatic transfer switches are generally used in applications where operating personnel are available and the...

Страница 8: ... Four Year Extended Warranty Parts Labor 5EXW300 Five Year Extended Warranty Parts Labor 9 UL Type 1 Enclosure See notes below for information on Type 3R 4 12 Enclosures Switch Rating amps Phase Poles Neutral Code Dimensions In mm 3 Width Height Depth Approx Shipping Weight Lb kg 4 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3 30 70 100 104 150 200 230 260 400 600 800 1000 1200 1600 20001 6 2600 30002 A...

Страница 9: ... Four Year Extended Warranty Parts Labor 5EXW300 Five Year Extended Warranty Parts Labor 9 UL Type 1 Enclosure See notes below for information on Type 3R 4 12 Enclosures Switch Rating amps Phase Poles Neutral Code Dimensions In mm 3 Width Height Depth Approx Shipping Weight Lb kg 4 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3 30 70 100 104 150 200 230 260 400 600 800 1000 1200 1600 20001 6 2600 30002 A...

Страница 10: ... Four Year Extended Warranty Parts Labor 5EXW300 Five Year Extended Warranty Parts Labor 9 UL Type 1 Enclosure See notes below for information on Type 3R 4 12 Enclosures Switch Rating amps Phase Poles Neutral Code Dimensions In mm 3 Width Height Depth Approx Shipping Weight Lb kg 4 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3 30 70 100 104 150 200 230 260 400 600 800 1000 1200 1600 20001 6 2600 30002 A...

Страница 11: ...cations interface module RS 485 to allow local or remote communications with ASCO PowerQuest VPi or SiteWeb communication products l Special Enclosures Specify by appropriate code in catalog number Type 3R Raintight Type 4 Weatherproof Type 12 Oil Tight User Initiated Control ASCO 386 non automatic transfer switches are generally used in applications where operating personnel are available and the...

Страница 12: ...cations interface module RS 485 to allow local or remote communications with ASCO PowerQuest VPi or SiteWeb communication products l Special Enclosures Specify by appropriate code in catalog number Type 3R Raintight Type 4 Weatherproof Type 12 Oil Tight User Initiated Control ASCO 386 non automatic transfer switches are generally used in applications where operating personnel are available and the...

Страница 13: ...sary to allow correct control settings prior to shipment Specific Volt Freq Options Enclosure Blank Open Type C M N Q 11CD 115 120 208 220 230 240 380 400 415 440 460 480 575 600 To order an ASCO Series 300SE Power Transfer Switch complete the following catalog number Dimensions Shipping Weights for Series 300SE Transfer Switches Ordering Information for Series 300SE Transfer Switches UL Type 1 En...

Страница 14: ...CO 5200 Series Power Manager as shown above it provides the most economical communication system for monitoring and control of power transfer switches and engine generators The local RS 485 network allows communications with up to 32 power transfer switches and four engine generators An analog phone connection and ASCO telephone interface module allow for direct dial up monitoring and control of r...

Страница 15: ...CO 5200 Series Power Manager as shown above it provides the most economical communication system for monitoring and control of power transfer switches and engine generators The local RS 485 network allows communications with up to 32 power transfer switches and four engine generators An analog phone connection and ASCO telephone interface module allow for direct dial up monitoring and control of r...

Страница 16: ...Quest VPi Software Package VPi 32 15 Fig 19 Thin Web Server Fig 18 Telephone Interface Module PowerQuest VPi vs Communication Interface Module Acc 72A Communication Interface Module to allow local remote or web enabled communications with ASCO PowerQuest VPi or SiteWebTM communication products An accessory 72A is required on each power transfer switch Feature P Po ow we er rQ Qu ue es st t V VP Pi...

Страница 17: ...Quest VPi Software Package VPi 32 15 Fig 19 Thin Web Server Fig 18 Telephone Interface Module PowerQuest VPi vs Communication Interface Module Acc 72A Communication Interface Module to allow local remote or web enabled communications with ASCO PowerQuest VPi or SiteWebTM communication products An accessory 72A is required on each power transfer switch Feature P Po ow we er rQ Qu ue es st t V VP Pi...

Страница 18: ...mprehensive maintenance agreements that detail the preventive care needed to keep emergency power systems ready to respond A service agreement is an effective way to budget in advance and avoid unexpected expenditures A 35 point checklist is utilized to assure critical systems and components are kept in top operating condition These preventive programs can be customized for national accounts This ...

Отзывы: