background image

Product Safety Information

Signal Words Defined

DANGER

indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING

indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE

is used to address practices not related to physical injury.

Safety Instructions

WARNING—MODIFICATIONS

Do not modify these devices in anyway. Replace any missing or broken parts with proper Appleton replacement parts. Modification 
of these devices or substitution of parts with non-standard parts may result in serious or fatal person injury from electrocution.

WARNING—PRODUCT DAMAGE

If any part of the plug appears to be missing, broken, or show signs of damage—discontinue use immediately! This condition
could cause serious or fatal personal injury due to electrocution and/or equipment damage. Repair with the proper replacement
part(s) before continuing service.

WARNING—ELECTRICAL

Electrical power must be turned OFF before and during installation and maintenance. Failure to do so may result in serious or fatal
injuries due to electrocution

WARNING—WIRING

Plug and cord connectors are rated for use with Type SO cord with copper conductors ONLY.

Except as expressly provided by 

Appleton Grp, LLC

 (Appleton), Appleton products are intended for ultimate purchase by industrial users and for operation by persons trained and experienced in the use and maintenance of this equipment 

and not for consumers or consumer use. Appleton warranties DO NOT extend to, and no reseller is authorized to extend Appleton’s warranties to any consumer.

While every precaution has been taken to ensure accuracy and completeness in this manual, 

Appleton Grp, LLC

. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or 

omissions. Specifications are subject to change without notice. The Appleton and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners.  
©201

5

 

Appleton Grp

, LLC. All rights reserved. 

330100-000 Rev. 

F

 05/15  • Page 

 of 

Содержание Appleton U-Line ECP-1523

Страница 1: ...unts of dust are present or amounts which would otherwise affect performances Installation WARNINGS Electrical power must be turned OFF before and during installation and maintenance Failure to do so may result in serious or fatal injuries due to electrocution Use cable diameters ranging from 0 538 to 0 639 inches Failure to do so may result in overstressed wire terminations which may cause the co...

Страница 2: ...g strap terminal with grounding strap WHITE wire to lug terminal with WHITE DOT Other two wires to remaining lug terminals BLACK wire to remaining lug terminal Tighten the terminal screws to a torque of 15 in lb 7 Slide insulator clamp down the cord and position over terminals The insulator clamp has two slots which engage with the arc barrier walls providing proper orientation Continue to slide t...

Страница 3: ...E If any part of the plug appears to be missing broken or show signs of damage discontinue use immediately This condition could cause serious or fatal personal injury due to electrocution and or equipment damage Repair with the proper Appleton replacement part s before continuing service During the inspections perform the following steps 1 Inspect all contact wire terminals for tightness and retor...

Страница 4: ...numbers ECP 20232 and NCP 20232 are for use with the following receptacles Cat No followed by M indicates malleable iron receptacle in non hazardous areas EFS150 20232 EFSC150 20232 EFSB150 2023 EFSCB150 20232 EFS250 20232 EFSC250 20232 EFS175 20232 EFSC175 20232 EFSB175 20232 EFSCB175 20232 EFS275 20232 EFSC275 20232 EFS110 20232 EFSC110 20232 ECCL 20232 ECH20232 EFS210 20232 EFSC210 2023 EFSR 20...

Страница 5: ...523 NCP 2023 NCP 1523 125 V 20 A 1hp 125 V 20 A 1hp EFSC250 2023 UGR10 2023 ENRC 12201 2 1 2 2 125 V 20 A 1hp 125 V 15 A 1hp ECP 2023 ECP 1523 NCP 2023 NCP 1523 125 V 20 A 1hp 125 V 20 A 1hp EFSC275 2023 UGR11 2023 ENRC 22201 2 3 4 2 125 V 20 A 1hp 125 V 15 A 1hp ECP 2023 ECP 1523 NCP 2023 NCP 1523 125 V 20 A 1hp 125 V 20 A 1hp EFSC210 2023 UGR12 20231 ENRC 32201 2 1 2 125 V 20 A 1hp ECP 2023 NCP ...

Страница 6: ...ng service WARNING ELECTRICAL Electrical power must be turned OFF before and during installation and maintenance Failure to do so may result in serious or fatal injuries due to electrocution WARNING WIRING Plug and cord connectors are rated for use with Type SO cord with copper conductors ONLY Except as expressly provided by Appleton Grp LLC Appleton Appleton products are intended for ultimate pur...