manualshive.com logo in svg
background image

Intermateability—Plugs & Receptacles

Table 2

Appleton 

Plug Rating

Appleton 

“ECP” Plug  

Cat. No.

Appleton 

“NCP” Plug 

Cat. No.

Receptacle 

Rating

Appleton 

Receptacle 

Cat. No.

Killark 

Receptacle 

Cat. No.

Crouse-

Hinds 

Receptacle 

Cat. No.

No. of 

Conduit 

Openings

Hub 
Size 

in.

No. 

of 

Gangs

125 V, 15 A, 1hp

ECP-1523

NCP-1523

125 V, 20 A, 1hp

EFSR-2023

UGRO-20231

ENR-5201

---

---

---

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFS150-2023

UGR1-20231

ENR-11201

1

½

1

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFS175-2023

UGR2-20231

ENR-21201

1

3/4

1

125 V 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFS110-2023

UGR3-20231

ENR-31201

1

1

1

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFSC150-2023

UGR4-20231

ENRC-11201

2

½

1

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFSC175-2023

UGR5-20231

ENRC-21201

2

¾

1

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFSC110--2023

UGR6-20231

ENRC-31201

2

1

1

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFS250-2023

UGR7-20231

ENR-12201

1

1/2

2

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFS275-2023

UGR8-20231

ENR-22201

1

¾

2

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFS210-2023

UGR9-20231

ENR-32201

1

1

2

125 V, 20 A, 1hp 
125 V,15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFSC250-2023

UGR10-2023

ENRC-12201

2

1/2

2

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFSC275-2023

UGR11-2023

ENRC-22201

2

3/4

2

125 V, 20 A, 1hp 
125 V, 15 A, 1hp

ECP-2023 
ECP-1523

NCP-2023 
NCP-1523

125 V, 20 A, 1hp 
125 V, 20 A, 1hp

EFSC210-2023

UGR12-20231

ENRC-32201

2

1

2

125 V, 20 A, 1hp

ECP-2023

NCP-2023

125 V, 20 A, 1hp

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFSR-20232

UGR0-20232

ENR-6202

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

ERFS150-20232

UGR1-20232

ENR-11202

1

½

1

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFS175-20232

UGR2-20232

ENR-21202

1

¾

1

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFS110-20232

UGR3-20232

ENR-31202

1

1

1

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFSC150-20232

UGR4-20232

ENRC-11202

2

½

1

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFSC175-20232

UGR5-20232

ENRC-21202

2

3/4

1

250 V, 20A, 2hp 

ECP-20232

250 V, 20 A, 2hp

EFSC110-20232

UGR6-20232

ENRC-31202

2

1

1

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFS250-20232

UGR8-20232

ENR-12202

1

1/2

2

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFS275-20232

UGR8-20232

ENR-22202

1

3/4

2

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFS210-20232

UGR9-20232

ENR-32202

1

1

2

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFSC250-20232

UGR10-20232

ENRC-12202

2

½

2

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFSC275-20232

UGR11-20232

ENRC-22202

2

3/4

2

250 V, 20 A, 2hp

ECP-20232

250 V, 20 A, 2hp

EFSC210-20232

UGR12-20232

ENRC-32202

2

1

2

NOTE: 

The Appleton “ECP” or “NCP” “D” Plug and “EFS” Receptacle is a UL Listed Combination. The Appleton Series “ECP” or 

“NCP” Model “D” Plug with Killark UL Listed “UGR” Series Receptacle or with Crouse-Hinds UL Listed “ENR” Series Receptacle  

is a UL Listed Classified Combination

.

330100-000 Rev. 

F

 05/15  • Page 

 of 

Appleton • 1.800.621.1506 • www.appletonelec.com

Содержание Appleton U-Line ECP-1523

Страница 1: ...unts of dust are present or amounts which would otherwise affect performances Installation WARNINGS Electrical power must be turned OFF before and during installation and maintenance Failure to do so may result in serious or fatal injuries due to electrocution Use cable diameters ranging from 0 538 to 0 639 inches Failure to do so may result in overstressed wire terminations which may cause the co...

Страница 2: ...g strap terminal with grounding strap WHITE wire to lug terminal with WHITE DOT Other two wires to remaining lug terminals BLACK wire to remaining lug terminal Tighten the terminal screws to a torque of 15 in lb 7 Slide insulator clamp down the cord and position over terminals The insulator clamp has two slots which engage with the arc barrier walls providing proper orientation Continue to slide t...

Страница 3: ...E If any part of the plug appears to be missing broken or show signs of damage discontinue use immediately This condition could cause serious or fatal personal injury due to electrocution and or equipment damage Repair with the proper Appleton replacement part s before continuing service During the inspections perform the following steps 1 Inspect all contact wire terminals for tightness and retor...

Страница 4: ...numbers ECP 20232 and NCP 20232 are for use with the following receptacles Cat No followed by M indicates malleable iron receptacle in non hazardous areas EFS150 20232 EFSC150 20232 EFSB150 2023 EFSCB150 20232 EFS250 20232 EFSC250 20232 EFS175 20232 EFSC175 20232 EFSB175 20232 EFSCB175 20232 EFS275 20232 EFSC275 20232 EFS110 20232 EFSC110 20232 ECCL 20232 ECH20232 EFS210 20232 EFSC210 2023 EFSR 20...

Страница 5: ...523 NCP 2023 NCP 1523 125 V 20 A 1hp 125 V 20 A 1hp EFSC250 2023 UGR10 2023 ENRC 12201 2 1 2 2 125 V 20 A 1hp 125 V 15 A 1hp ECP 2023 ECP 1523 NCP 2023 NCP 1523 125 V 20 A 1hp 125 V 20 A 1hp EFSC275 2023 UGR11 2023 ENRC 22201 2 3 4 2 125 V 20 A 1hp 125 V 15 A 1hp ECP 2023 ECP 1523 NCP 2023 NCP 1523 125 V 20 A 1hp 125 V 20 A 1hp EFSC210 2023 UGR12 20231 ENRC 32201 2 1 2 125 V 20 A 1hp ECP 2023 NCP ...

Страница 6: ...ng service WARNING ELECTRICAL Electrical power must be turned OFF before and during installation and maintenance Failure to do so may result in serious or fatal injuries due to electrocution WARNING WIRING Plug and cord connectors are rated for use with Type SO cord with copper conductors ONLY Except as expressly provided by Appleton Grp LLC Appleton Appleton products are intended for ultimate pur...

Отзывы: