background image

6

9. The fan comes with blue, black and white leads

that are 80-inches long. Before installing fan, mea-
sure up approximately 6 to 9-inches above the
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.

10. Use three 10-32 x 3/8" pan head screws and flat

washers (supplied) to secure flange to blade, as
shown below. Repeat for the remaining four
blades.

11. Use the 10 round recessed holes in the motor hub

marked with "5" and install the five blade assemblies
(ordered separately) in accordance with Step 12.

12. Attach one blade assembly to the motor hub using

two 10-32 x 5/8" oval head screws (supplied). Do
not tighten completely at this time. Install remain-
ing blade assemblies in the same way. Gently
snug all flange screws to the motor hub, working
around the hub in a clockwise sequence. Next,
securely tighten all flange screws, again working in
a clockwise sequence. Failure to follow this proce-
dure could result in fan wobble. This completes
the blade installation.

13. Remove the fan motor and housing assembly

from the styrofoam packaging. Position the motor
so that the bottom of the motor is facing you.
Engage the connector of the switch cup assembly
with the motor connector by aligning the V-notch
shaped keyways and pressing the connectors
firmly together until they fully mate. The V-notch
keyways prevent the connectors from being
engaged improperly.

14. Position the switch cup assembly on the motor

switch plate and align the holes in the cup assem-
bly with the holes around the side of the switch
cup plate. Secure The switch cup assembly by
installing three 8-32 x 3/8" flat head screws
(supplied in loose parts bag).

SWITCH 
HOUSING
ASSEMBLY

SWITCH CUP
ASSEMBLY

8-32 X 3/8"
FLAT HEAD
MOUNTING
SCREWS (3)

SWITCH CUP
PLATE

8-32 x 3/8"
FLAT HEAD
MOUNTING
SCREWS (3)

SWITCH 
CUP
PLATE

To avoid possible fire or shock, do not pinch wires
between the switch cup assembly and the switch
cup plate.

WARNING

!

To reduce the risk of personal injury, do not bend the
blade flanges when installing the blades or cleaning
the fan. Do not insert foreign objects between rotat-
ing fan blades.

WARNING

!

BLADE FLANGE

FAN BLADE

10-32 x 3/8" PAN
HEAD SCREW (3)

FLAT WASHER (3)

SWITCH HOUSING
PLATE

MOTOR
HUB

1/4-20 x 1/2" 
FLANGE SCREWS (2)
(INSTALL THROUGH SLOT
IN SWITCH HOUSING PLATE)

MOTOR 
CONNECTOR

SWITCH 
HOUSING 
CONNECTOR

SWITCH HOUSING
ASSEMBLY

SWITCH  CUP 
CONNECTOR

MOTOR 
CONNECTOR

Содержание APOLLO CF3900AB01

Страница 1: ...ANY 52 APOLLO Series Model No CF3900WW01 CF3900AW01 CF3900AB01 CF3900PB01 CF3900WPB01 CF3900OB01 CF3900HTW01 CF3900BS01 CF3900BQ01 CF3900TG01 CF3900CK01 APOLLO Series Ceiling Fan Owner s Manual Net Weight 18 0 Lbs Part No F40BP72340003 Form No BP7234 3 ...

Страница 2: ...vice center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty...

Страница 3: ...cian 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt ...

Страница 4: ...ff boxes are provided next to each step As each step is com pleted place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted CEILING COVER FOAM PACKING PROTECTIVE PLASTIC BAG FOAM PACKING CARTON MOTOR AND HOUSING ASSEMBLY HANGER BALL DOWNROD ASSEMBLY HANGER BRACKET LOOSE PARTS BAG BLADE FLANGES MOTOR COVER ...

Страница 5: ...r Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude install two knurled knobs supplied to secure the cover NOTE Make sure the red and brown leads are capped with wire connectors and are completely inside motor cover and not pinched between the motor cover and motor 7 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with...

Страница 6: ...so that the bottom of the motor is facing you Engage the connector of the switch cup assembly with the motor connector by aligning the V notch shaped keyways and pressing the connectors firmly together until they fully mate The V notch keyways prevent the connectors from being engaged improperly 14 Position the switch cup assembly on the motor switch plate and align the holes in the cup assem bly ...

Страница 7: ...uld wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box...

Страница 8: ...et box is ground ed contact a licensed electrician for advice as it must be grounded for safe operation WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 5 Secure the ceiling cover in place by sliding lock washe...

Страница 9: ...1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson ...

Страница 10: ... 21 22 9 10 7 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION NAME OF ITEM MODEL NUMBER THE PART NUMBER THE PART DESCRIPTION For repair parts phone 1 800 654 3545 10 ...

Страница 11: ...61621 9 761621 12 761621 15 761621 19 761621 13 761621 20 761621 22 23 Motor 762304 762304 762304 762304 762304 762304 762304 762304 762304 762304 762304 Parts Bag containing 762020 762020 1 762020 762020 762020 1 762020 762020 2 762020 1 762020 1 762020 762020 4 Pin Clevis 1 5 Clip Hairpin 1 11 Coupling 1 12 Pendant 1 14 Wire Connector 3 15 Wrench Hex 3 16 1 16 Stud Threaded 1 1 4 2 17 Lockwasher...

Страница 12: ...e wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing 6 Screws holding blades to flanges are loose 6 Tighten screws securely WARNING Make sure main power is turned off 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten the setscrew in the motor coupling excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighte...

Отзывы: