![Emerson 818-9010 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/emerson/818-9010/818-9010_installation-and-operation-manual_102010055.webp)
• 49
Kind of Action
1B; Pollution Grade: 2
Software Class: A
Rated Inpulsive
Voltage
2500V;
Overvoltage Category: II
Operating
Temperature
-10 to 60°C (14°F to 140°F)
Storage Temperature: -30 to 85°C
(-22°F to 185°F)
Relative Humidity
20 to 85% (non-condensing)
Measuring and
Regulation Range
PTC probe: -50 to150°C (-58°F
to 302°F)
NTC probe: -40 to110°C (-40°F
to 230°F)
Pt1000 probe: -50 to100°C
(-58°F to 212°F)
Pressure transducer:
-1.0 to 50.0 Bar (-14.5 PSI to 725
PSI)
Resolution
0.1°C or 1°F; Accuracy@ 25°C:
±0.1°C ±1 digit
Case
4 DIN
Table 13-1
- XEV20D Technical Specifications
Содержание 818-9010
Страница 1: ...026 1731 Rev 0 01 DEC 2014 High Pressure CO2 Controller Installation and Operation Manual ...
Страница 2: ......
Страница 4: ......
Страница 19: ...Figure 3 1 MODBUS Networking 13 ...
Страница 45: ...Figure 10 29 Override Screen 39 ...
Страница 49: ...Figure 12 2 High Pressure CO2 Device Wiring and Network Connection 43 ...