![Emerson 378254 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/emerson/378254/378254_installing-and-operating-instructions_20996018.webp)
1592006207 XB570L GB r1.1 23.03.2015 XB570L
16/20
18. TECHNICAL DATA
Housing:
self extinguishing ABS
Case:
frontal 185x38 mm; depth 70mm
Mounting:
panel mounting in a 150x31mm panel cut-out
Frontal protection:
IP65
Connections:
screw terminal block
≤
2.5mm
2
wiring
Power supply:
230Vac,
±
10%
Power absorption:
5VA max
Display:
dual display
Inputs:
5 PTC or NTC probes
Relay outputs:
Compressor:
relay SPST 20(8)A or 8(3) A, 250Vac
Defrost:
relay 8(3)A, 250Vac
Fans:
relay SPST 8(3)A, 250Vac
Light:
relay SPST 16(6)A, 250Vac
Aux1:
relay SPST 8(3)A, 250Vac
Aux2:
relay SPST 16(6)A, 250Vac
Serial output:
RS232 serial output for XB07PR printer connection
Serial output:
TTL serial output for monitoring system (MODBUS-RTU) protocol
Data storing:
on the non-volatile memory (EEPROM)
Data storage:
non-volatile memory (EEPROM)
Kinf of action:
1B
Pollution degree:
normal
Software class:
A
Operating temperature:
0 to 60°C (32 to 140°F)
Storage temperature:
-30 to 85°C (-22 to 185°F)
Relative humidity:
20 to 85% (no condensing)
Measuring range:
-55 to 50°C (-67 to 122°F)
NTC probe:
-40 to 110°C (-40 to 230°F)
PTC probe:
-50 to 150°C (-55 to 302°F)
Resolution:
0.1°C or 1°F (selectable).
Accuracy of the controller at 25°C:
±
0.3°C
±
1digit
19. STANDARD VALUE OF THE CYCLES.
Cy1: for fast chilling and conservation of foods at positive
temperature
CyS
= tEP
iS2
= 5°C (41°F)
Pd3
= OFF
dbC
= no
rS2
=-2°C (28°F)
dbH
= yes
iS1
= 20°C (68°F)
Pd2
= 2.0 h
HdS
= 3°C (37°F)
rS1
= -10°C (14°F)
iS3
= 3°C (37°F)
Pd1
= 2.0 h
rS3
=-2°C (28°F)
Cy2: for chilling and fast freezing of foods with holding
CyS
= tEP
iS2
= 5°C (41°F)
Pd3
= 2.0 h
dbC
= no
rS2
= -2°C (28°F)
dbH
= YES
iS1
= 10°C (50°F)
Pd2
= 2.0 h
HdS
=-18°C (0°F)
rS1
= -10°C (14°F)
iS3
=-18°C (0°F)
Pd1
= 2.0 h
rS3
=-30°C (-22°F)
Cy3: direct fast freezing with holding
CyS
= tEP
iS2
=-18°C (0°F)
Pd3
= OFF
dbC
= no
rS2
=-30°C(-22°F)
dbH
= yes
iS1
= -18°C (0°F)
Pd2
=OFF
HdS
= -18°C (0°F)
rS1
=-30°C (-22°F)
iS3
=-18°C (0°F)
Pd1
= 4.0
rS3
=-30°C (-22°F)