background image

www.white-rodgers.com

4

 MOUNTING AND WIRING 

 

CONTINUED FROM SECOND PAGE

RH

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 2. Typical wiring diagram for

heat only,  3-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Y

RC

JUMPER

WIRE

O

B

For 2-wire Heat only, 
attach to RH and W

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

TRANSFORMER

THERMOSTAT

SYSTEM

G

W

Figure 3. Typical wiring diagram for

cool only, 3-wire, single transformer systems

Cooling
System

Fan

Relay

RC

O

B

JUMPER

WIRE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 4. Typical wiring diagram for

heat/cool, 4-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

JUMPER

WIRE

O

B

RED jumper wire (provided with thermostat) must be 
connected between thermostat 

RH and RC terminals 

for proper thermostat operation with this system.

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 5. Typical wiring diagram for

heat/cool, 5-wire, two-transformer systems

HEATING

TRANSFORMER

Heating

System

Fan

Relay

Cooling
System

RC

24 VAC

120 VAC

Hot

Neutral

COOLING TRANSFORMER

O

B

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 6. Typical wiring diagram for heat pump

with reversing valve energized in COOL

TRANSFORMER

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the

   system switch is in the COOL position

Fan

Relay

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Figure 7. Typical wiring diagram for heat pump

with reversing valve energized in HEAT

TRANSFORMER

Reversing

Valve*

RC

O

B

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the

   system switch is in the HEAT position

Fan

Relay

5

 CHECK THERMOSTAT OPERATION

NOTE

To prevent static discharge problems, touch side of thermo-
stat to release static build-up before touching any keys. 

If at any time during testing your system does not operate properly, 
contact a qualified service person.

Fan Operation

If  your  system 

does  not  have  a  G  terminal  connection,  skip  to 

Heating System.

1.  Turn on power to the system.
2.  Move FAN switch to

 ON position. The blower should begin to 

operate.

3.  Move FAN switch to 

AUTO position. The blower should stop im-

mediately.

Cooling System

To  prevent  compressor  and/or  property  damage,  if  the 
outdoor temperature  is below  50°F, DO  NOT  operate  the 
cooling system.

CAUTION

!

This thermostat has a time delay between cooling cycles to allow 
the head pressure in the compressor to stabilize. If the temperature 
is  adjusted  to  call  for  cool  within  5  minutes  of  the  last  cycle  the 
snowflake icon will blink indicating the thermostat is locked out. Af-
ter 3 to 5 minutes, the compressor will start and the snowflake icon 
will stop flashing. This helps prevent the compressor from cycling 
too quickly and is normal operation for the thermostat.

1.  Move SYSTEM switch to 

COOL position.

2.  Press 

  to  adjust  thermostat  setting  below  room  tempera-

ture. The blower should come on immediately on high speed, 
followed by cold air circulation

3.  Press 

 to adjust temperature setting above room tempera-

ture. The cooling system should stop operating.

Heating System

1.  Move SYSTEM switch to 

HEAT position. If the heating system 

has a standing pilot, be sure to light it.

2.  Press 

 to adjust thermostat setting above room tempera-

ture. The heating system should begin to operate.

3.  Press 

 to adjust temperature setting below room tempera-

ture. The heating system should stop operating.

Содержание 1F78

Страница 1: ...mostat With wires still attached remove wall plate from the wall If the old thermostat has a wall mounting plate remove the thermostat and the wall mounting plate as an assembly 4 Identify each wire attached to the old thermostat 5 Disconnect the wires from the old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures PART NO 37 6...

Страница 2: ...onic systems Both settings produce a very accurate temperature control and can be set to your personal preference As received the thermostat cycles the system just under 1 F With W905 clipped the system cycles at approxi mately 1 5 F Take care when securing and routing wires so they do not short to adjacent terminals or rear of thermostat Personal injury and or property damage may occur CAUTION TE...

Страница 3: ...ER WIRE Reversing valve is energized when the system switch is in the HEAT position Fan Relay 5 CHECK THERMOSTAT OPERATION NOTE To prevent static discharge problems touch side of thermo stat to release static build up before touching any keys If at any time during testing your system does not operate properly contact a qualified service person Fan Operation If your system does not have a G termina...

Страница 4: ...the next program period be gins Then the thermostat will automatically revert to the pro gram HOLD TEMPERATURE The thermostat can hold any tem perature within its range for an indefinite period without re verting to the programmed temperature Press HOLD button HOLD will be displayed Then choose the desired temper ature by pressing or The thermostat will hold the room temperature at the selected se...

Страница 5: ...es you want during each period You may also want to look at the sample program table to get an idea of how the thermostat can be programmed 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH SAMPLE Heating Cooling Schedule Plan Factory Program 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 70 F 62 F 70 F 62 F 78 F 85 F 78 F 82 F 70 ...

Страница 6: ... TO AUTOMATICALLY PROVIDE MAXIMUM COMFORT AND EFFICIENCY 7 SPECIFICATIONS ELECTRICAL DATA Electrical Rating MV to 30 VAC 50 60 Hz or D C 0 05 to 1 0 Amps Load per terminal 1 5 Amps Maximum Total Load All terminals combined THERMAL DATA Setpoint Temperature Range 45 F to 90 F 7 C to 32 C Operating Ambient Temperature Range 32 F to 105 F 0 C to 41 C Operating Humidity Range 0 to 90 RH non condensing...

Страница 7: ...to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Furnace Cycles Too Fast or Too Slow narrow or wide temperature swing The location of the thermostat and or 1 the size of the Heating System may be influencing the cycle rate Digital thermostats normally provide precise temperature control and may cycle faster than some older mechanical models...

Страница 8: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Страница 9: ... com www emersonclimate com LÍNEA DE AYUDA PARA EL USUARIO 1 800 284 2925 White Rodgers es una división de Emerson Electric Co El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co ...

Страница 10: ...ncionando correctamente Si el sistema funciona correctamente cambie el termostato Los ciclos de la caldera son 1 La ubicación del termostato y o el tamaño del Normalmente los termostatos digitales proporcionan un demasiado cortos o demasiado sistema de calefacción pueden influir en la control preciso de la temperatura y pueden apagarse y largos oscilación reducida o duración de los ciclos encender...

Страница 11: ... AUTOMÁTICA EL MÁXIMO CONFORT Y EFICIENCIA 7 ESPECIFICACIONES DATOS ELÉCTRICOS Características eléctricas MV a 30 VCA 50 60 Hz o CC 05 a 1 0 amps carga por terminal Carga total máxima 1 5 amps todas las terminales combinadas DATOS TÉRMICOS Rango de temperaturas de referencia 45 F a 90 F 7 C a 32 C Temperatura ambiente operativa 32 F a 105 F 0ºC a 41ºC Humedad operativa 0 a 90 HR sin condensación T...

Страница 12: ...igeración para el programa semanal Utilice la tabla que se encuentra al pie de la página para planificar las horas y temperaturas de programación que desea durante cada período También puede consultar la tabla de ejemplos de programas para tener una idea de cómo programar el termostato 1 2 3 4 1 2 3 4 EJEMPLO Plan de programación de calefacción refrigeración programa de fábrica 6 00 AM 8 00 AM 5 0...

Страница 13: ...a MANTENER TEMPERATURA El termostato puede mantener cual quier temperatura dentro de su rango por un tiempo indefinido sin volver a la temperatura programada Presione el botón HOLD Apare cerá HOLD en la pantalla Luego elija la temperatura deseada pre sionando o El termostato mantendrá la temperatura am biente al valor seleccionado hasta que presione el botón RUN para volver a iniciar la ejecución ...

Страница 14: ...ERIFIQUE EL FUNCIONAMIENTO DEL TERMOSTATO NOTA Para evitar problemas de descarga estática toque la parte lateral del termostato para liberar la estática acumulada antes de pulsar cualquier tecla Si en algún momento durante la prueba su sistema no funciona correcta mente póngase en contacto con un servicio técnico calificado Funcionamiento del ventilador Si su sistema no tiene una conexión terminal...

Страница 15: ...exacto y pueden ajustarse según su preferencia personal Tal como se envía de fábrica el termostato apaga y enciende el sistema debajo de 1 F Con el cable de puente W905 cortado el sistema se apagará y encenderá a aproximadamente 1 5 F Al fijar y pasar los cables tenga cuidado de que no hagan cortocircuito con las terminales adyacentes o en la parte trasera del termostato Podrían producirse lesione...

Страница 16: ...esión o articulada b La base que se quita aflojando todos los tornillos imperdibles c La subbase de conmutación que se quita desenroscando los tornillos de montaje que la sostienen sobre la pared o la placa adaptadora 2 Apague la electricidad en la caja de fusibles principal hasta que haya finalizado la instalación Asegúrese de que la alimentación eléctrica esté desconectada 3 Retire la cubierta d...

Отзывы: