Emerson Quiet Kool EBTC08RE1T Скачать руководство пользователя страница 13

8

1

2

3

4

5

6

7

8

9

1.                              Without timer setting,the 

operation mode is Cooling,Dry, Fan and Auto,and 
the set temperature will be displayed.
Time will be displayed under timer setting.

Digital Display:

       and      Button:

2.                                    Use these buttons on the 

control panel and remote to increase or decrease 
the Set Temperature or Timer. 
Temperature range: 61

~88

 or 16

~31

.

3.                             Turn the air conditioner on and 

off.

Power Button:

                          Press the mode button to cycle 
through the various modes: Cool, Dry, Fan and 
Auto, or Heat.

4.

Mode Button:

                          Use these buttons on the control 
panel and remote to set the Timer. 

Timer Off:

 The timed stop is programmed by 

pressing TIMER button. Set the rest time by 
pressing the button 

or 

until the rest 

time displayed is to your demand then press 
TIMER button again.

Timer On: 

When the unit is off, press TIMER 

button at the first time, set the temperature with 
pressing the button 

or 

. Press TIMER 

button at the second time, set the rest time with 
pressing the button 

or 

. Press TIMER 

button at the third time, confirm the setting, then 
the rest time to next automatical switching-on 
could be read on the display of the machine. 

Note:

 It can be set to automatically turn off or on in 

0.5-24 hours. Each press of the

 

buttons will increase or decrease the timer. The 
Timer can be set in 0.5 hours increment below 10 
hours and 1 hour increment for 10 hours or above. 
The SET light will turn on while setting. 
To cancel the setted function, press the TIMER 
button again.

5.

Timer Button:

Cool Mode:

 The cooling function allows the air 

conditioner to cool the room and at the same time 
reduces Air humidify. Press the MODE button to 
activate the cooling function. To optimize the
function of the air conditioner, adjust the 
temperature and the speed by pressing the button 
indicated.

Dry Mode: 

This function reduces the humidity of 

the air to make the room more comfortable. Press 
MODE button to set the DRY mode. An automatic 
function of alternating cooling cycles and air fan 
is activated. 

Fan Mode: 

The conditioner works in only 

ventilation. Press MODE button to set the FAN 
mode. With pressing FAN SPEED button the 
speed changes in the following sequence: Hi, Med 
and Lo in FAN mode. The remote control also 
stories the speed that was set in the previous 
mode of operation.

 

Auto Mode: 

In AUTO mode the unit automatically 

chooses the fan speed and the mode of operation
(COOL,DRY or FAN).In this mode the fan speed 
and the temperature are set automatically 
according to the room temperature (tested by the 
temperature sensor which is incorporated in the 
indoor unit.).

Heat Mode:

 The heating function allows the air 

conditioner to heat the room. Press the MODE 
button to activate the cooling function. To optimize 
the function of the air conditioner, adjust the 
temperature and the speed by pressing the button 
indicated.

AUTO
SPEED

AUTO
MODE

1

2

3

4

5

6

7

8

9

HEAT

AUTO
SPEED

AUTO
MODE

For Cooling model

For Heating model

Содержание EBTC08RE1T

Страница 1: ...MODEL EBTC08RE1T EBTC10RE1T EBTC10RE2T EBTC12RE1T EBTC12RE2T EBTC12RD2T EBTE14RRDT THRU THE WALL AIR CONDITIONER ...

Страница 2: ......

Страница 3: ......

Страница 4: ...N IMPORTANT SAFETY INSTRUCTION PACKING LIST INSTALLATION ASSEMBLY INSTRUCTIONS USING YOUR AIR CONDITIONER CARE AND CLEANING TROUBLESHOOTING ELECTRICAL REQUIREMENTS OPERATING YOUR AIR CONDITIONER 1 2 3 4 8 10 11 12 ...

Страница 5: ...1 ...

Страница 6: ...2 8K 10K 12K 14K Cooling 8K Cooling Heating 10K 12K 14K Cooling Heating ...

Страница 7: ... Trim Frame 2 Top Bottom legs Grille Aluminum Rear plastic net PAPT QUANTITY IMAGE PAPT QUANTITY Dimension Seal sponge 1 x3 4 x14 2 Seal sponge 1 x3 8 x14 2 Seal sponge 1 x3 8 x25 3 Seal sponge 1 x1 1 2 x25 3 Seal sponge 1 x1 1 2 x14 2 Seal sponge 1 x1 1 2 x84 1 Seal cotton 3 3 4 x1 1 2 x4 4 Seal cotton 3 4 x1 1 2 x17 2 4 1 1 1 2 2 1 1 or ...

Страница 8: ...placement installations a Frigidaire Sleeve Kit EA108T is recommended CAUTION When installation is complete replacement unit must have rearward slope as shown in Fig 1 2 Remove old Air Conditioner from wall sleeve and prepare as followings Clean interior Do not disturb seals Check the wall sleeve be securely fastened in wall before installing Add more nails or screws if needed Repair painted surfa...

Страница 9: ...below pictures Remove the existing grille and save the mounting screws Place the grille included with your new air conditioner towards the inside rear of the sleeve Attach the new grille by aligning the four mounting holes Re insert the self tapping screws into the nylon retainers 2 Grille Remove Important Single intake grille must be removed when used with dual intake TTW unit Warning When removi...

Страница 10: ...the top of the unit The overhang on each side is equal 4 If the unit has not been predrilled some model carefully drill 4 1 8 holes through the grille and into the side flange of the unit approximately 1 1 2 to 2 from the top and bottom as Fig 2 or 3 Be careful not to break the copper pipe 5 Install 4 8 self tapping screws to affix the grille to the unit 6 Insert the unit into the sleeve Grille to...

Страница 11: ...ration instruction 2 Before sliding unit all the way back remove second screw from left side of unit 3 Remove plastic washer from screw 4 Screw the other end of the ground wire into the unit as shown Make sure the toothed washer is against the cabinet 5 Slide unit completely to the rear Non Frigidaire Dual Intake Grille In case where the existing sleeve is a non Frigidaire sleeve but is installed ...

Страница 12: ...d seal with the stuffing seal supplied with the kit Trim Kit Installation Instructions 1 Install the 1 x1 x84 long stuffer seal between the wall sleeve and the unit A flat bladed screwdriver or putty knife is needed 2 Assemble the trim frame by inserting the top and bottom pieces into side pieces and snapping into place 3 Pull the cord through the trim frame and slide the trim over the unit until ...

Страница 13: ...ove The SET light will turn on while setting To cancel the setted function press the TIMER button again 5 Timer Button Cool Mode The cooling function allows the air conditioner to cool the room and at the same time reduces Air humidify Press the MODE button to activate the cooling function To optimize the function of the air conditioner adjust the temperature and the speed by pressing the button i...

Страница 14: ...30 60 minutes and at most change six times until the set temperature is 28 For heating mode the set temperature will automatically decrease by 1 every 30 60 minutes and at most change six times until the set temperature is 24 And every running time depends on the set temperature 7 Sleep Button Press the FAN SPEED button to choose the fan speed options You can choose Hi Med Lo or auto speed in COOL...

Страница 15: ...he display of the machine Note It can be set to automatically turn off or on in 0 5 24 hours Each press of the buttons will increase or decrease the timer The Timer can be set in 0 5 hours increment below 10 hours and 1 hour increment for 10 hours or above The SET light will turn on while setting To cancel the setted function press the TIMER button again 5 Timer In AUTO mode the unit automatically...

Страница 16: ...11 FIG 21 FIG 21 ...

Страница 17: ...12 ...

Страница 18: ...13 For any questions or Technical Support Please Call Customer Service 1 844 801 8880 ...

Страница 19: ......

Страница 20: ......

Отзывы: