I/O Connections:
Proportional pump (mod. “IS” driven by pulses) outputs:
1(-)
;
2(+):
Output
P1
3(-)
;
4(+):
Output
P2
5(-)
;
6(+):
Output
P3
7(-)
;
8(+):
Output
P4
9(-)
;
10(+):
Output
P5
11(-)
;
12(+):
Output
P6
mA outputs (max resistive load: 500 Ohm):
13:
Common
14:
mA
output
1
15:
mA
output
2
16:
mA
output
3
17:
mA
output
4
18:
mA
output
5
19:
mA
output
6
(temperature*)
*0°C / 4mA - 100°C / 20mA
RS485:
26: + Signal RS485 (A)
27:
-
Signal
RS485
(B)
Tank Level inputs:
29 (-) ; 30 (+) Level 1
31 (-) ; 32 (+) Level 2
33 (-) ; 34 (+) Level 3
35 (-) ; 36 (+) Level 4
37 (-) ; 38 (+) Level 5
Proximity Sensor (mod. “SEPR”) input:
39(+ Brown) ; 40(Black) ; 41(- Blue)
41
shortcut
with
block
n.37
Contact input
*
:
39(White)
;
40(Black)
41
shortcut
with
block
n.37
set flow option from setup menu
(Hall effect) pulse sender water meter:
42(+12VDC) ; 43(INPUT) ; 44(GND)
(Contact) Pulse sender water meter:
43(INPUT) ; 44(GND)
Temperature Probe input for mod. “PT100”** only:
50(green) ; 51(brown) ; 52(white) ; 53(yellow)
(remove resistance before to install probe)
Temperature Probe input for “PT100”
with
50(green) ; 51(orange or pink) ; 52(white) ; 53(yellow)
ECDIND probe:
(Ref. A Appendix - Inductive Conductivity module)
Standby signal input:
54(+)
;
55(GND)
*This is “FLOW1” for “MAX5 PH CL PH CL double flow” model only
**This is “TEMP2” for “MAX5 PH CL PH CL double flow” model only
OPTO COUPLED
SIGNALS
(-) is NOT a shared
signal !
OPTIONAL OUTPUTS
on demand
GND is a shared ground
(-) is a shared (GND)
ground signal !
OPTIONS
OPTIONS
OPTIONS
Содержание MAX5
Страница 41: ...41 Appendix B Installation draw ...
Страница 53: ...53 ...
Страница 54: ...54 ...
Страница 55: ...55 ...