![Emec LOTUS MINI Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/emec/lotus-mini/lotus-mini_operation-manual_2399986024.webp)
33
COMMUNICATION (LOG
MENU
& LOGBOOK
MENU
)
This function, when enabled, allows to record and send to ERMES server all instrument activities (date, time, temperature,
levels, alarms, totalizers, outputs status) for a set period (EVERY) and starting from a certain time (TIME) .
Note: SET TIME AND DATE PRIOR TO ENABLE THE LOG. If not fed after 30 days the instrument will lose current date
and time.
TIME: log starting time (format 23h 59min)
EVERY: frequency of recording (format 23h 59min)
E.g.: To set the instrument to begin logging events starting from 16:00 every hour set TOME to 16h: 00 and EVERY of 1h: 00m
Note: To view on instrument’s display the archived logs select LOGBOOK