22
This diagram shows all the
possible alarms.
ALARM
LEVEL
Key
ALARM
SEFL
Key
ALARM
STD-By
Key
over
flow
Key
Key
ALARM
stroke
ALARM
POWER
Key
10. PUMP’S FUNCTIONS SUMMARY- ALARMS
If any alarm is active, in the menù “
Pump’s functions summary
” a general alarm display will show the
number
of alarm active
at the moment. Enter into this menu with “
RIGHT
” key.
The windows displayed show which alarms are active.
Level alarm: the level probe signals the product
end.
SEFL alarm signals an anomaly for the SEFL.
Stand-by alarm signals the pump stop.
Over flow alarm (when using “Divide”, “Multiply”,
“ppm” working mode): signals the working
frequency of the pump is higher than the values
on the label.
Power alarm signals the power supply is out of
range (from 180 to 260 VAC).
Stroke alarm signals that it has been set a capacity
higher than the value on the label.
Key
ALARM
batch
Key
Batch alarm signals that the pumps has received a
pulse while in Batch working mode.
ALARM
N° 01
STROKES
100 SPM
SUPPLY
220 VAC
DOSING
0.000 lph
Key
Key
Key
Key
Key
input
196 lph
Key
MODE
divide
Содержание KMS AC MF
Страница 55: ...55 0218 l h 18 bar 2 Pump head mod M l h bar...
Страница 57: ...57 C APPENDIX DELIVERY CURVES FOR COMPRESSED AIR MODELS 140 SPM 1018 l h 18 bar 10 Pump head mod M l h bar...
Страница 58: ...58 D APPENDIX DIMENSIONS bold mm inches Dimensions...
Страница 62: ...62 H APPENDIX MASTER SLAVE PUMPS CONNECTION master slave...
Страница 65: ......
Страница 66: ......