background image

1

Read Carefully !

ENGLISH Version

R17-04-20

“CENTURIO PRO” & “CENTURIO POOL”

  Controllers Operating Manual

This manual contains safety information that if ignored can 
endanger life or result in serious injury. They are indicated by 
this icon.

Keep the CONTROLLER protected from sun and water. 
Avoid water splashes.

REMOTE CONTROL AND SETUP

www.ermes-server.com

Depending on  choosen configuration, controller’s main screen may 
appear different and some functions couldn’t be present.

Содержание Centurio POOL

Страница 1: ...tion that if ignored can endanger life or result in serious injury They are indicated by this icon Keep the CONTROLLER protected from sun and water Avoid water splashes REMOTE CONTROL AND SETUP www er...

Страница 2: ...rized personnel only Always discharge the liquid end before servicing pumps connected to the CONTROLLER Empty and rinse the liquid end before work on a connected pump which has been used with hazardou...

Страница 3: ...idity from 0 to 9999 NTU Potentiostatic 5 PPM Temperature from 0 to 200 C Conductivity from 0 to 300 0 mS Conductivity Ind from 0 to 30 000 uS Dissolved Oxygen 0 to 20 mg l Conductivity and optional m...

Страница 4: ...s label LF LIVE FUSE PROTECTED Live input for motorized EV 41 N C contact 42 Common 43 N O contact Free of voltage contact max insulation 250V RELAY n 1 44 N C contact 45 Common 46 N O contact Free of...

Страница 5: ...output n 4 NPN max 50mA 24VDC 33 34 Proportional pump driven by pulses optocoupled signal output n 5 NPN max 50mA 24VDC 35 36 Proportional pump driven by pulses optocoupled signal output n 6 NPN max 5...

Страница 6: ...meters for input bleed see settings to configure For more info about serial number ERMES code tap on it to see an explanation popup Red icon requires user attention Please tap on it for further inform...

Страница 7: ...TROLLER PASSWORD for main menu settings access To grant access into main menu tap on from main screen and enter the PASSWORD using the keypad on the right side of the screen Default PASSWORD is 0000 f...

Страница 8: ...me is essential to setup time and date prior to anything Within International menu please choose language and location for proper units format Based on location units change according to local rules T...

Страница 9: ...irst Point Second Point During this procedure probe must be dry and clean and not installed in plant Tap on First Point zero and confirm it Tap on Second point dip probe s head into buffer solution an...

Страница 10: ...something wrong occurs use RECOVERY CALIBRATION to restore to previous calibration Two points calibration method During this procedure probe must be dry and clean and not installed in plant Use chlori...

Страница 11: ...11 Chlorine probes table Use this table to refer to calibration method to use Note some probes aren t supported...

Страница 12: ...robe s sensor on 7pH buffer solution Wait until reading value is stable and according to buffer solution value enter it on calibration field Cal at field Confirm it or discard if not satisfied Note bu...

Страница 13: ...setpoint for each channel on off mode only and assign an output available Parameters to set are 1 Working mode digital or proportional 2 Values 3 Output if available 4 Pulses per Minute For each setp...

Страница 14: ...1 40 the output will be permanently OFF For reading values 0 80 the output will be ON for 60 seconds and OFF for 40 seconds If reading value is 1 1 mg l then the output will be active at 30 ON for 30...

Страница 15: ...ROPORTIONAL mode between 1 00Cl 0 p m and 0 50Cl 180 p m p m is pulses per minute In this mode the Cl pump will be ON for values lower than 0 50mg l with set pulses minute capacity e g 180 and it ll b...

Страница 16: ...LI Set pH value at 7 00 OFF and 6 90 ON Set Pulse Speed per minute strokes per minute based on dosing device capabilities CONTROLLER will leave the pH pump active until reading value will increase up...

Страница 17: ...or base especially for soluble bases This broad use of the term is likely to have come about because alkalis were the first bases known to obey the Arrhenius definition of a base and are still among t...

Страница 18: ...e output on timered basis Reaching the set value the PWM will permanently leave on or off the output Parameters to set for this mode are Unit Value time activity towards set value 0 means 0 seconds 10...

Страница 19: ...t enable or disable the pH pump To use this mode tap on Proportional First Point Tap on it PROPORTIONAL mode between 7pH 0 P m and 8pH 180 P m p m is pulses per minute In this mode the pH pump will be...

Страница 20: ...he tracer pump active until reading value will increase up to 7 00ppm At 7 00ppm the tracer pump will be disabled until reading value will decrease under 6 90ppm Set Point ppm on off example n 2 trace...

Страница 21: ...alarm message 0 disabled max delay 999 minutes Label This menu allows to name the controller to better identify it within a network alerts messages Default name Centurio PRO Water Meters This menu all...

Страница 22: ...Probe Clean settings This menu allows to configure the cleaning mode of probes with built in cleaning sensor By assigning the relay to which the cleaning motor is connected you can set Cycle Time tim...

Страница 23: ...ter games lighting Options are Name timer name Digital Output choose between any available relay or free contact output or disabled Out Proportional choose between any available pulse output or disabl...

Страница 24: ...erator if required enter the access point name Usually this field is automatically assigned Username Enter SIM Username if required Password Enter SIM Password if required WARNING THIS FUNCTION COULD...

Страница 25: ...able At the end of scanning procedure tap on preferred network name and if needed enter password If preferred network SSID name is hidden ask to local ADMINISTRATOR about parameters to set Message Thi...

Страница 26: ...sting Dynamic Host Configuration Protocol DHCP computer from a pool of IP addresses The temporary IP address is called a dynamic IP address Requesting DHCP computers receive a dynamic IP address think...

Страница 27: ...nt of collected data period plotting time may be longer USB Pendrive Centurio PRO controller can import export data such as setpoint configuration backup restore log activity and firmware update throu...

Страница 28: ...e of pipes CORROSION SETPOINT This setpoint acts on the operating activity of the inhibitor if the instrument is set in WaterMeter PPM or CC ST mode For inhibitor control mode it is necessary to confi...

Страница 29: ...alarm messages Log Enable or disable logging of the event log CORROSION ALARM Absolute absolute alarm algorithm Track track alarm algorithm Indifferently select one of the two modes to enable the alar...

Страница 30: ...SETTINGS ALLOY Based on the construction material of the pipes select the most suitable alloy factor value according to the following table It is possible to assign a name to the type of material by...

Страница 31: ...priority over the chlorine dosage Flocculant flocculation for the removal of colloidal particles Through this menu Settings Flocculant it is possible to configure the entire flocculation procedure to...

Страница 32: ...echlorination activity Chlorine shock chlorination activity Through this menu Settings Chlorine it is possible to set a daily weekly timer to activate shock chlorination This procedure allows you to d...

Страница 33: ...ater is not stable but tends to dissociate continuously according to the reaction HClO H and ClO The dissociation of hypochlorous acid is strongly influenced by the pH value of the water as shown in t...

Страница 34: ...RNAL DEVICE LITTLE DIPER TRACER 1 GND i e black wire for tracer probe 2 12VDC i e red wire for tracer probe 3 PT100 yellow wire 4 PT100 white wire 5 PT100 brown wire 6 PT100 green wire 7 mA signal INP...

Страница 35: ...lue and black wire Connection for CD INDUCTIVITY PROBE mod S 1 n a 2 PT100 white wire 3 PT100 white wire 4 PT100 black wire 5 PT100 black wire 6 PROBE power supply red wire 7 PROBE signal green wire 8...

Страница 36: ...CL6 black wire This module is suitable for following probes SCL 1 PT100 yellow wire 2 PT100 white wire 3 PT100 brown wire 4 PT100 green wire 5 n a 6 GND SCL black wire 7 5VDC SCL red wire 8 RS485 SCL...

Страница 37: ...8 Probe Type 1 Brown Probe Type 2 Grey Transparent 9 Probe Type 1 White Probe Type 2 Shield 10 Probe Type 1 Green Probe Type 2 Black 1 2 3 4 5 6 7 8 9 10 TURBIDITY This module is suitable for TURBIDI...

Страница 38: ...e wire 6 Torb Probe Brown wire 7 Torb Probe Black wire 8 Torb Probe White wire 9 Torb Probe Green wire 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 ETRC2 ECORR MODULE This module is suitable for ETRC2 ECORR pr...

Страница 39: ...using to ensure protection against aggressive c h e m i c a l s a n d t o u g h environment ENCLOSURE 10 C 50 C 14 F 122 F 0 95 non condensing relative humidity ENVIRONMENT 4 5 6 7 8 A B C D E F 253 7...

Страница 40: ...lower part of the wall mounting rack To unlock controller from the wall pull 3 the handle from the wall mounting rack and raise up 4 the controller 1 2 3 4 5 6 7 8 Progettato da Controllato da Data E...

Страница 41: ...ge of the cables wires through the rubber pad it is necessary to make a cut in correspondence of the hole in order to favor the entrance of cable Once the cable is inserted it is possible to reassembl...

Страница 42: ...d Slots order shown on the display is progressive from left to right 1 2 3 4 5 6 7 8 9 101112 13141516171819202122 SLOT6 SLOT5 SLOT4 SLOT3 SLOT2 SLOT1 I O Connections 1 mA Output n 6 n a 3 mA Output n...

Страница 43: ...crews and open main panel as shown in figure to gain access to modules connectors A B A WiFi Module Installation Insert the module on the connector highlighted in the figure Make sure that the antenna...

Страница 44: ...44 Appendix Logical Working Scheme pool...

Страница 45: ...page 13 Settings menu page 21 Communication ADVANCED SETTINGS ERMES Mobile Ethernet Messages WiFi Proxy Graphics menu page 27 USB pendrive setup page 27 CENTURIO PRO antocorrosion config settings pag...

Страница 46: ...14 35 UE Direttiva EMC Compatibilit Elettromagnetica EMC electromagnetic compatibility directive EMC directiva de compatibilidad electromagn tica 2014 30 UE EN ISO 12100 Sicurezza del macchinario Safe...

Страница 47: ...47...

Страница 48: ...l types and send them according to local recycling disposal requirements We appreciate your efforts in supporting your local Recycle Environmental Program Working together we ll form an active union t...

Отзывы: