background image

DPSI BMS                               Operating Manual 

             Version 1.0 

Page 28 of 32 

 



 

Always pay attention to fully charge batteries when operating your 
model. Empty batteries lead inevitably to the breakdown of the 
RC components and therefore to the loss of the model. 



  Do not expose the DPSI BMS to extremely hot or cold 

temperatures, wetness or humidity. Here, there is danger of 
malfunction, damage or reduced performance.  



 

Only use our accessories in conjunction with the DPSI BMS (e.g. 
on/off switch). 

 

 

Содержание RC Electronic DPSI BMS

Страница 1: ...Operating Manual...

Страница 2: ...ery Connectors 13 8 Charging Instructions for Batteries 15 9 Initial Operation 16 9 1 Automatically Switching On Off 16 9 2 Manually Switching On Off 18 9 3 The DPSI BMS in Operation 18 9 4 LC Display...

Страница 3: ...ad this operating manual carefully in order to use all functions of the DPSI BMS optimally We wish you continued success and enjoyment with this high quality product 2 Features The DPSI BMS Dual Power...

Страница 4: ...rical connection between each other exists This allows you to use one battery for the ignition system and another one for the receiver set and operate both without any influence Due to the galvanic se...

Страница 5: ...n both sides with most modern parts allow for optimal space usage and are integrated into a stable and ergonomic housing Usage of pin and socket connectors allow for simple exchange of connector cable...

Страница 6: ...nel version and 2 channel version available 3 Properties of the DPSI BMS Displaying system for two separate batteries in battery switches or other applications Easily fitted between battery and consum...

Страница 7: ...characters each Actual voltage battery 1 and battery 2 Actual current battery 1 and battery 2 Minimum voltage battery 1 Minimum voltage battery 2 Maximum voltage battery 1 Maximum voltage battery 2 M...

Страница 8: ...of 32 4 Packing Contents Included in delivery of the DPSI BMS DPSI BMS basis device Screwing frame for M3 stop nuts 2 pieces of screws M3x20 with stop nuts Bracket for securing the MPX connectors Ope...

Страница 9: ...onnector cables 30 cm 11 8 each which are put in between the DPSI BMS and the battery switch 1 cable for the 1 channel version Therefore no soldering work is necessary if MPX connectors are already in...

Страница 10: ...the accompanying frame which serves as a counter bearing By the way the frame can serve as a positioning device for the cutout of the DPSI BMS The screwing connection is accomplished with the delivere...

Страница 11: ...put in between the batteries and the battery switch This means both batteries are disconnected from the battery switch and connected to the inputs of the DPSI BMS The DPSI BMS outputs are then connec...

Страница 12: ...DPSI BMS Operating Manual Version 1 0 Page 12 of 32...

Страница 13: ...his marking must be strictly observed The cables are first stripped approx 5 mm 0 2 and then tin plated Before soldering the cables to the connectors don t forget to put the shrink hoses to the cable...

Страница 14: ...2 Soldering Multiplex connectors Hint It is necessary to use one shrink hose per cable see photo for isolation and not to put a shrink hose over both cables There must be enough space between the posi...

Страница 15: ...I BMS during charging and having an additional charging input e g V cable or charging connector must be charged separately if the DPSI BMS is connected to a battery switch Please observe the operating...

Страница 16: ...different ways Automatically turning On Off Manually turning On Off 9 1 Automatically Switching On Off Automatically turning on of the DPSI BMS always works As soon as the connected consumer e g a rec...

Страница 17: ...below 100 to 150 milli amps the DPSI BMS turns off after approx 10 seconds Hint As soon as the receiver set is turned off and the current from battery 1 drops below approx 100 to 150 milli amps the DP...

Страница 18: ...he current is higher than 150 milli amps 9 3 The DPSI BMS in Operation Hint For operation battery 1 has to be connected because the electronics of the DPSI BMS are supplied by battery 1 The micro cont...

Страница 19: ...nnected or its voltage is too low the value 4 0V is displayed If the voltage of one connected battery exceeds 20 volts 20V is displayed CAUTION only a max of 16 volts are allowed Display of actual cur...

Страница 20: ...urned on maximum value 20 0V Maximum current from battery 1 since last turned on If the value I is 150mA this is indicated accordingly Maximum current from battery 1 since last turned on This value in...

Страница 21: ...value higher than 13 00A is displayed as 13 00A Average current from battery 2 since last turned on Maximum current from both batteries since last turned on This value indicates peak currents in the e...

Страница 22: ...ceeding 9999mAh the value 9999mAh is displayed Operating time flight time in minutes since last reset of the memory Caution only full minutes are saved If turned off at 1 59 next turning on shows 1 mi...

Страница 23: ...tery 1 since last turned on max value 20 0V Maximum current from battery 1 since last turned on Maximum current from battery 1 since last turned on This value indicates the peak current which was reac...

Страница 24: ...1 0 Page 24 of 32 Operating time flight time in minutes since last reset of the memory Caution only full minutes are saved If turned off after 1 59 next turning on shows 1 minute If exceeding 9999 mi...

Страница 25: ...t of the saved values press the button and turn on the DPSI BMS Press the button for approx 5 seconds If the button is pressed for 5 seconds during turning on this display appears Releasing the button...

Страница 26: ...ox 5 seconds programming mode is entered which works as follows If both arrow keys were pressed for 5 seconds during turning on programming mode starts After releasing the next display appears Indicat...

Страница 27: ...njury Always double check all connections in your model before any usage All connections must be of the correct polarity have a clean contact and be secured Loose cables pose a potential hazard Under...

Страница 28: ...batteries lead inevitably to the breakdown of the RC components and therefore to the loss of the model Do not expose the DPSI BMS to extremely hot or cold temperatures wetness or humidity Here there...

Страница 29: ...Voltage Drop 5A 100mV Galvanically Separation Both batteries totally decoupled CE Test According to 89 336 EWG Environmental Conditions Operating 14 F 122 F Permissible Temperature Range 13 F 185 F D...

Страница 30: ...uring the period of guarantee the warranty shall cover the repair or replacement of any proven manufacturing or material defects at no charge There shall be no specific entitlement to repair work In c...

Страница 31: ...have been undertaken It must have been operated in accordance with our operating instructions Only the power sources and other accessory devices and components that were recommended by us may have bee...

Страница 32: ...medium or translated into any other language without the express written approval of EMCOTEC GmbH Manual Note EMCOTEC GmbH reserves the right to make changes to this manual and to equipment described...

Отзывы: