Содержание Locating Beeper

Страница 1: ......

Страница 2: ...5 2 Mounting 6 3 Functionality 7 3 1 Low Voltage Code 8 3 2 Model Finder Code Failsafe 9 4 Specifics of PRO Version 10 4 1 Deactivating the Alarm Function 11 4 2 Deactivating the Alarm Signals 13 4 3...

Страница 3: ...ge e g 4 0V and then quit The Locating Beeper functions down to a voltage of 2 8 volts i e even when the servos quit working a long time ago The Solution The Locating Beeper model finder is the soluti...

Страница 4: ...ally stops when the battery is fully charged There are many advantages by using this new revolutionary battery type practically no self discharge and virtually unlimited life span up to 1 million char...

Страница 5: ...o on Also usable as tow rope finder if tow rope falls into hard to view terrain only PRO version Finding is accomplished by an ear piercing tone with more than 90dB sound pressure Two SMD loudspeaker...

Страница 6: ...r during operation close to or into the ear This can lead to permanent damage of the sense of hearing 2 Mounting Delivery of the Locating Beeper includes a tube clamp This clamp is simply mounted onto...

Страница 7: ...a servo which is connected in parallel to the Locating Beeper e g choke servo or tow release Failsafe setting of the servo position e g turning the transmitter off Missing or erroneous servo signal e...

Страница 8: ...the receiver voltage drops below 4 8 volts an alarm sounds after a qualification time of 2 seconds i e a continuously repeating alarm signal The signal corresponds to the low voltage code of the EMCO...

Страница 9: ...than 2 2ms corresponds to 175 Servo pulse distance is smaller than 10ms error malfunction Servo pulse distance is longer than 40ms no servo signal Servo pulse exceeds failsafe threshold 100 Supply vol...

Страница 10: ...odel finder alarm S O S alarm signal which results from an erroneous servo signal is still output by the PRO version if the receiver supply is interrupted or missing The S O S alarm signal is repeated...

Страница 11: ...O must be deactivated before turning the receiver off otherwise an alarm is triggered In order to inhibit undesired alarm output the servo signal must be switched 2 times between 2 values in between a...

Страница 12: ...rol and function test Hint An acoustically confirmation is output after a deactivating sequence is recognized The alarm function is then locked for 60 seconds If the receiver is turned off within thes...

Страница 13: ...ending on the event which triggered the alarm If the alarm was triggered by servo signal monitoring Deactivation only by a valid servo signal i e turning the receiver back on Deactivation of the alarm...

Страница 14: ...o extension cord close to the tow release of the model which connects to a free receiver channel Remove the plastic housing at the fuselage side of the cable see photo so the plug of the Locating Beep...

Страница 15: ...4 2 A similar application is monitoring of dropped parts e g model sky diver Here too the Locating Beeper eases locating An additional application is monitoring of supply voltages of electronically s...

Страница 16: ...ery The system needs a few seconds to get ready if the integrated battery of the Locating Beeper PRO is totally discharged This is recognized by a strange clicking noise with different beeps of the Lo...

Страница 17: ...e Range 20 C 70 C 4 F 158 F Reverse Polarity Protection Yes Dimensions 43 2mm x 17 8mm 1 7 x 0 7 length x diameter Weight 11g 0 353658 oz Specialties PRO Version Current Consumption turned off 1 A Cur...

Страница 18: ...ion of all connections in your model before each use All plugs must be correctly polarized and have clean contacts i e fit tightly Loose cables present a potential hazard Under no circumstances may po...

Страница 19: ...must be sent to the appropriate service center of the respective country or directly to EMCOTEC GmbH The guarantee shall only be valid when the following conditions are met The guarantee document orig...

Страница 20: ...any type of medium or translated into any other language without the express written approval of EMCOTEC GmbH Manual Note EMCOTEC GmbH reserves the right make changes to this manual and to equipment d...