![EMC TWT8G-200 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/emc/twt8g-200/twt8g-200_operating-and-maintenance-instructions-manual_2399684026.webp)
MAN-70007, Rev B, 02-20-2016
Page
26
of
31
PowerMax Innovation Inc.
1243 Reamwood Ave.,
Sunnyvale, CA 94089
Tel.: 408-541-0888; Fax. 408-541-1886
SYSTEM STATUS RESPONSES FOR AMP
Command Code
Amplifier Response
Description
STATUS
POWER-OFF
Amplifier Initialization or rebooting
POWER-ON
Amplifier POWER-ON mode
RF-OFF
Amplifier RF-OFF mode
RF-ON
Amplifier RF-ON mode
FAULT
The Amplifier has a Fault
WARNING
The Amplifier has a warning
STATUSALL
“Model, Warning, Amp status”
Multistate status string
WARNING
Returns warning message
FAULT
Returns Detailed Message
THERMAL FAULT
High Temperature Fault
HIGH VSWR FAULT
When VSWR is greater then set value
HELIX CURRENT FAULT
When Helix current exceed the allowable limit
HELIX VOLTAGE FAULT
When Helix voltage is out of range
FILAMENT FAULT
When Filament current is low
SUM FAULT
HV Power supply faults
LOW AIRFLOW FAULT
When airflow is low
NO FAULTS
No fault condition