Status lights visible from the rear of a DAE-AX
Table 4
DAE-AX status lights visible from the rear
LED
Quantity
State
Meaning
Solid green
LCC is receiving ac power
LCC power
1 per LCC
Off
No power
LCC fault
1 per LCC
Solid amber
LCC has encountered a problem
Solid green
Indicates normal connection
LCC connectivity
2 per LCC
Blinking green
Connection is expected, but is not
detected
Solid amber
Indicates a connection problem.
LCC connection fault
2 per LCC
Blinking amber
Indicates a problem with the connection.
Solid amber
Power supply is faulted
Blinking amber
Power supply is not seated
Power supply fault
1 per power supply
Off
Indicates normal activity
Solid green
Indicates ac power and normal acitvity
Power supply on/off
1 per power supply
Off
No ac power
Solid amber
Indicates a cooling fault
Cooling fault
1 per power
supply/system
cooling module
Off
Indicates blower is operating normally
18
Hardware and Operational Overview