3.2 Linux System Quick Operation
Windows System Environment Preparation
In the course of system operation, when needs HyperTerminal in the PC, the Hyper Terminal
configuration is as follows:
Baud rate: 115200
Data bit: 8
Parity check: no
Stop bit: 1
SOC8200 Hardware Environment Preparation
Before booting the linux system, you should make sure the following labeled before turn on
power:
1.
Confirm that you have connected the LCD. (If you have bought the LCD)
2.
Confirm whether the SD card accessed
;
3.
Confirm whether the serial port accessed
;
4.
Confirm that you have connect the interface where the yellow box marked on the map.
If got the confirmation, please connect 12V power supply, when the hyper terminal on the
PC shows SOC8200 information, it proves successful.
If you need to use VGA interface, please note the above-mentioned the yellow box which you
should connect