background image

• 

The Always On outlets are recommended for use with Audio Visual 
(AV) equipment that requires constant power for timers, program 
guide and recording features (e.g. DVR, PVR, VCR, cable box, digital 
TV receivers, game consoles, hard drives or bedside alarms). This will 
ensure constant power is not interrupted to these devices.

• 

The Power Saving outlets are recommended for Audio Visual  
(AV) equipment that can be automatically switched off (e.g. 
televisions, amplifiers, stereos, speakers, sound bars, DVDs, CDs,  
Blu-ray players, lamps).

• 

Overload protection circuit breaker reset button.

• 

3 pins for use with standard North American wall outlets.

• 

The Infrared Classic Sensor activates the Power Saving outlets, 
monitors activity and is also used to set the Active Powerdown®.  
It comes with a 9.8 ft/3 m cable, LED light and integrated push  
button control.

• 

The Protected light should be on. If this light turns off or is dim,  
you may have a ground-wiring problem in your home and you  
should contact an electrician to properly ground the outlet.

• 

The Power Saving Outlets On light shows the state of the Power 
Saving outlets. When the light is on, the Power Saving outlets  
are powered; if the light is off, no power is flowing to the Power 
Saving outlets.

6

Содержание ESUSAV8-ET-10C

Страница 1: ...Emberstrip 8AV With Classic Sensor ESUSAV8 ET 10C User manual PATENTS GRANTED AND PATENTS PENDING V12...

Страница 2: ...ensor in a convenient location that is in line of sight Close to your television is the best position and within normal operation of your existing remote control s The Classic Sensor detects use of an...

Страница 3: ...ng OFF your AV equipment Simply turn your equipment off in the normal way The Embertec Emberstrip 8AV will then remove power from the Power Saving outlets after a delay of approximately 1 minute NOTE...

Страница 4: ...tion guide 2 Quick operation guide 3 What you need to know 7 Active Powerdown settings 10 MusicMode settings 11 BedroomMode settings 12 Fast facts 13 Specifications and compliance 14 Troubleshooting g...

Страница 5: ...rstrip 8AV 1 Embertec Emberstrip 8AV 2 Classic Sensor 3 On Off Power Saving outlets indicator light 4 Power Saving outlets 5 Always On outlets 6 Overload protection Reset Button 7 Surge protection lig...

Страница 6: ...amps Overload protection circuit breaker reset button 3 pins for use with standard North American wall outlets The Infrared Classic Sensor activates the Power Saving outlets monitors activity and is a...

Страница 7: ...out Ensure cords plugged into the Embertec Emberstrip 8AV remain tangle free It is recommended to regularly inspect the Embertec Emberstrip 8AV for damage The Embertec Emberstrip 8AV must not be used...

Страница 8: ...1 hour which can be permanently set to 2 hours or temporarily 8 hours MusicMode When will Active Powerdown switch the Audio Visual AV equipment off If your Embertec Emberstrip 8AV detects that your Au...

Страница 9: ...res such as DVD recorders pay TV and PVR units cable boxes hard drives game consoles or digital receivers Certain home theater projectors that require a cool down period including rear projection tele...

Страница 10: ...r which is aimed to maximize your home s energy savings Follow these instructions to change Active Powerdown to 2 hours this may be preferred for longer movies or programs where remote control activit...

Страница 11: ...you switch your appliances off Remember 1 In this mode your system will stay on for 8 hours unless you switch your appliances off 2 Your permanent Active Powerdown timer setting will revert to 1 or 2...

Страница 12: ...switched on before starting 1 Press and hold the SET button on the Classic Sensor for 3 seconds then release The LED light on the front of the sensor will flash starting from a faint flash slowly pro...

Страница 13: ...h a safety device that removes power in the event of overloading Should this occur turn off and unplug all units and press the reset button Then plug into the wall outlet again Once reset use any remo...

Страница 14: ...5 RH at 122 F 50 C Protection and Safety Surge Compliance UL 1449 Powerstrip Safety Underwriters Laboratories Tested and Listed to UL 1449 and UL 1363 Total Surge 1 974 Joules 45 000 Amps for all outl...

Страница 15: ...with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause ha...

Страница 16: ...maybe interfering with the Embertec Emberstrip 8AV such as compact fluorescent lights computers mobile phones and other portable consumer electronic devices If possible relocate these interfering devi...

Страница 17: ...nd tear For purposes of this warranty improper use means not installing or operating the device in accordance with the manual Any incidental consequential special or other indirect damages are not rec...

Страница 18: ...in accordance with its manual Any damage to equipment that is not properly connected to an Embertec Emberstrip or damage to equipment connected to an Embertec Emberstrip that is not properly connected...

Страница 19: ...ower savings zero effort for computers and IT peripheral devices Check with your utility company or visit us on the web for more information Also in our range Emberstrip 8AV with Bluetooth Smart Senso...

Страница 20: ...hat you need assistance please contact us on 1 800 838 9659 or email us at customerservice embertec com or alternatively visit us on our website at embertec com Except as required by law Embertec is n...