EmberGlow 18DBNL-60 Series Скачать руководство пользователя страница 28

LIMITED WARRANTY

Sure Heat Mfg. warran ts that the components of this appliance are warranted free from
defects in material and workmanship for one (1) year from the date of purchase. Sure
Heat Mfg.at its option, willrepair or replace this product or any component of the product
found to be defective during the warranty period. Replacement willbe made with a new
manufactured product or component. If the product is no longer available, replacement may
be made with a similar product of equal value.This warranty does not include transportation 
or shipping costs of any kind. This is your exclusive warranty.

.

This warranty is validfor the original retail purchaser from the date of initial retail purchase
and is not transferable. Keep the original sales receipt. Proof of purchase is required to
obtain warranty parts.
This warranty does not cover normal wear of parts such as scratches and dents of the
components or damage resulting from any of the following:

negligent use or misuse of the product, includingexposing the product to chemicalsor cleaning products

not approved by Sure Heat Mfg.

corrosion, rust or discoloring of any kind

use or installationcontrary to specified instructions and applicable building codes, includingheating the

product to temperatures above its rated specifi cations which can cause considerable warping

disassembly, including removal of the product from a built-in installation

damage resulting from accident, alteration, misuse, abuse, hostile environments, or improper installation

repair or alteration

acts of God, such as  fire,flood, hurricanes, and tornadoes

gas cylinders,propane tanks or other fuel deliverysystems,including connections to a household fuel

supply

usage other than single-family household use such as commercial or industrial use

minor warping or discoloration of parts, which is normal and not a defect under this warranty

DO NOT RETURN THIS PRODUCT TO THE PLACE OF PURCHASE 

If the appliance does not operate properly , first thoroughly carry out the instructions
provided with the unit to ensure that the appliance is installed correctly and check the
troubleshooting section in this use and care manual.
We recommend you return this warranty registration card so that you can be contacted

should any questions of safety arise that could affect you. The return of the warranty
registration card is not a condition for warranty coverage.

Because of continuing product improvement, these specifications are subject to change
without notice.

If you have other questions or need replacement parts contact our

Customer Service Hotline at (800) 229-5647 or

visit our website at www.sureheat.com

Sure Heat Manufacturing, 3140 Moon Station Road, Kennesaw GA, 30144 

RMH-130-DB60
RTP  02-2016 

Purchased From: _________________________ ____________        Date: ____________
Model:

18DBNL-60 24DBNL-60 30DBNL-60

 Serial Number: ____________________

Name: ______________________________         Phone Number: ___________________

Address: _________________________________________________________________

City: _________________________________ State: ________       ZIP: ______________

Содержание 18DBNL-60 Series

Страница 1: ...your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be...

Страница 2: ...s manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its con trols can be dangerous 1 This appliance as supplied is only for use w...

Страница 3: ...his log set to cook food or burn paper or other objects 13 Logsetbecomesveryhotwheninuse Keep children and adults away from hot surface to avoid burns or clothing ignition Log set will remain hot for...

Страница 4: ...ose paint by a quali ed chimneycleaner Creosotewillignite if highly heated Adirty chi mney uemaycreateanddistribute soot within the house Inspect chimney ue for damage NOTICE Installation service and...

Страница 5: ...taching Damper Clamp CONNECTING TO GAS SUPPLY WARNING A quali ed service person must local codes connect log set to gas supply Follow all Installation Items Needed Before installing log set make sure...

Страница 6: ...from gas supply piping system 2 Cap off open end of gas pipe where equipment shut off valve was connected 3 Pressurize supply piping system by either using com pressed air or opening main gas valve l...

Страница 7: ...from Natural Gas to LP gas If connecting to a Propane gas system regulator must be switched prior to use Follow the the steps below to select Propane gas 1 Carefully remove the logs from the burner as...

Страница 8: ...s 4 When burner is tested and Leak free Observe individual tongues of ame on burner from ports Note Make sure that all ports are clear and pro ducing ame evenly across burner If any ports ap pear bloc...

Страница 9: ...G PLACEMENT MODEL BRO18DBNL 60 Place log 1 onto back left area of the grate perpendicular to log 2 Place Y shaped log 4 onto left of the grate ahead of raised area Place log 3 at the front right of th...

Страница 10: ...raised area Log Identification Back Log Stand Offs in place 1 2 3 4 6 7 8 9 on the grate finger left of center Place log 3 onto back left area of the grate perpendicular to log 1 Place log 4 at the fr...

Страница 11: ...LOG PLACEMENT MODEL BRO24DBNL 60 Cont Place the two small logs 7 and 8 in front of the grate as shown 11...

Страница 12: ...the grate Place shorter back log 2 onto Back Log Stand Offs in place Back Log Stand Offs 1 2 3 4 5 6 Place Cross Log 3 at the left side Place Cross Log 4 at the center Place Cross Log 5 at the right...

Страница 13: ...Log 7 atop the center Left 4 to the center right 5 logs 1 2 3 4 5 6 Log Identification MO24NG Follow the first five steps from MO18NG on previous page Place Cross Log 4 at the center right Place Y Sha...

Страница 14: ...grate Place shorter back log 2 onto raised area of the grate 1 2 3 Log Identification Back Log Stand Offs in place Place Cross Log 3 at the left side Place Cross Log 4 at the right side Place Cross Lo...

Страница 15: ...he grate Place shorter back log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 4 at the center left Place Cross Log...

Страница 16: ...LOG PLACEMENT MODEL SH24DBNL 60 cont Place cross log 7 atop cross log 6 and to front center as shown 16...

Страница 17: ...ack log 3 onto raised area of the grate Log Identification Back Log Stand Offs in place 1 2 Place left front log 2 onto front area of the grate 3 4 5 6 Place Cross Log 4 at the center left Place Y sha...

Страница 18: ...DEL CS30DBNL 60 Cont Place Cross Log 8 at the top center across logs 5 and 7 Place Cross Log 7 at the center right Place log 8 in front of the set on the fireplace floor Make sure it is in front of th...

Страница 19: ...TING INSTRUCTION 1 STOP Read the safety information on the left side of this page 2 Make sure equipment shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF position 4 Wai...

Страница 20: ...t hand side of the burner The thermocouple should be fully enveloped in the ame The ame should not be lifting off of the thermocouple element If your pilot assembly does not meet these require ments T...

Страница 21: ...ng down con trol knob Repeat igniting op eration until air is removed 5 6 Clean pilot see Cleaning and Maintenance above or replace pilot assembly Check replace gas regulator Pilot lights but ame goes...

Страница 22: ...REMEDY TROUBLESHOOTING Continued Delayed ignition burner 1 Pilot angle needs adjusting 2 Wrong pilot ori ce for gas type 1 Adjust pilot angle for best ame contact with burner pan 2 Replace pilot ori c...

Страница 23: ...L 15 18 2 16 13 6 10 14 11 7 5 9 12 1 8 3 4 28 20 19 LP Conversion Items 21 22 23 19 23 24 25 5 17 26 27 18 24 30 DBNL 60 PARTS...

Страница 24: ...Vented 22 SPSCJ00106A Standoff Back Log 23 Burner Spacer RMH 120 00420 RMH 120 PBAGA Pilot Bracket 24 RMH 120 00574 Damper Clamp RMH 120 00100 25 26 27 1 0 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RMH...

Страница 25: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 26: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 27: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 28: ...n misuse abuse hostile environments or improper installation repair or alteration acts of God such as fire flood hurricanes and tornadoes gas cylinders propane tanks or other fuel deliverysystems incl...