EmberGlow 18DBNL-60 Series Скачать руководство пользователя страница 1

Convertible from Natural Gas to Propane/LP Gas

OWNER'S OPERATION AND INSTALLATION MANUAL

WARNING: If the information in this manual is not

followed exactly, a

re or explosion may result causing

property damage, personal injury or loss of life.

— Do not store or use gasoline or other

ammable vapors

and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the

fire 

department.

— Installation and service must be performed by a quali-

ed installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

VENTED DECORATIVE APPLIANCE

18DBNL-60 AND 24DBNL-60

Listed By

Tested & 

Vented Decorative Appliances 

for installation in Solid Fuel 
Burning Fireplaces

Information included for the following log models:

 MO18DBNL-60
 MO24DBNL-60

BRO18DBNL-60
BRO24DBNL-60

 SH18DBNL-60
 SH24DBNL-60

 

CS30DBNL-60 (Shown)

C       US

Z21.60 2012

Содержание 18DBNL-60 Series

Страница 1: ...your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re department Installation and service must be...

Страница 2: ...s manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its con trols can be dangerous 1 This appliance as supplied is only for use w...

Страница 3: ...his log set to cook food or burn paper or other objects 13 Logsetbecomesveryhotwheninuse Keep children and adults away from hot surface to avoid burns or clothing ignition Log set will remain hot for...

Страница 4: ...ose paint by a quali ed chimneycleaner Creosotewillignite if highly heated Adirty chi mney uemaycreateanddistribute soot within the house Inspect chimney ue for damage NOTICE Installation service and...

Страница 5: ...taching Damper Clamp CONNECTING TO GAS SUPPLY WARNING A quali ed service person must local codes connect log set to gas supply Follow all Installation Items Needed Before installing log set make sure...

Страница 6: ...from gas supply piping system 2 Cap off open end of gas pipe where equipment shut off valve was connected 3 Pressurize supply piping system by either using com pressed air or opening main gas valve l...

Страница 7: ...from Natural Gas to LP gas If connecting to a Propane gas system regulator must be switched prior to use Follow the the steps below to select Propane gas 1 Carefully remove the logs from the burner as...

Страница 8: ...s 4 When burner is tested and Leak free Observe individual tongues of ame on burner from ports Note Make sure that all ports are clear and pro ducing ame evenly across burner If any ports ap pear bloc...

Страница 9: ...G PLACEMENT MODEL BRO18DBNL 60 Place log 1 onto back left area of the grate perpendicular to log 2 Place Y shaped log 4 onto left of the grate ahead of raised area Place log 3 at the front right of th...

Страница 10: ...raised area Log Identification Back Log Stand Offs in place 1 2 3 4 6 7 8 9 on the grate finger left of center Place log 3 onto back left area of the grate perpendicular to log 1 Place log 4 at the fr...

Страница 11: ...LOG PLACEMENT MODEL BRO24DBNL 60 Cont Place the two small logs 7 and 8 in front of the grate as shown 11...

Страница 12: ...the grate Place shorter back log 2 onto Back Log Stand Offs in place Back Log Stand Offs 1 2 3 4 5 6 Place Cross Log 3 at the left side Place Cross Log 4 at the center Place Cross Log 5 at the right...

Страница 13: ...Log 7 atop the center Left 4 to the center right 5 logs 1 2 3 4 5 6 Log Identification MO24NG Follow the first five steps from MO18NG on previous page Place Cross Log 4 at the center right Place Y Sha...

Страница 14: ...grate Place shorter back log 2 onto raised area of the grate 1 2 3 Log Identification Back Log Stand Offs in place Place Cross Log 3 at the left side Place Cross Log 4 at the right side Place Cross Lo...

Страница 15: ...he grate Place shorter back log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 4 at the center left Place Cross Log...

Страница 16: ...LOG PLACEMENT MODEL SH24DBNL 60 cont Place cross log 7 atop cross log 6 and to front center as shown 16...

Страница 17: ...ack log 3 onto raised area of the grate Log Identification Back Log Stand Offs in place 1 2 Place left front log 2 onto front area of the grate 3 4 5 6 Place Cross Log 4 at the center left Place Y sha...

Страница 18: ...DEL CS30DBNL 60 Cont Place Cross Log 8 at the top center across logs 5 and 7 Place Cross Log 7 at the center right Place log 8 in front of the set on the fireplace floor Make sure it is in front of th...

Страница 19: ...TING INSTRUCTION 1 STOP Read the safety information on the left side of this page 2 Make sure equipment shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF position 4 Wai...

Страница 20: ...t hand side of the burner The thermocouple should be fully enveloped in the ame The ame should not be lifting off of the thermocouple element If your pilot assembly does not meet these require ments T...

Страница 21: ...ng down con trol knob Repeat igniting op eration until air is removed 5 6 Clean pilot see Cleaning and Maintenance above or replace pilot assembly Check replace gas regulator Pilot lights but ame goes...

Страница 22: ...REMEDY TROUBLESHOOTING Continued Delayed ignition burner 1 Pilot angle needs adjusting 2 Wrong pilot ori ce for gas type 1 Adjust pilot angle for best ame contact with burner pan 2 Replace pilot ori c...

Страница 23: ...L 15 18 2 16 13 6 10 14 11 7 5 9 12 1 8 3 4 28 20 19 LP Conversion Items 21 22 23 19 23 24 25 5 17 26 27 18 24 30 DBNL 60 PARTS...

Страница 24: ...Vented 22 SPSCJ00106A Standoff Back Log 23 Burner Spacer RMH 120 00420 RMH 120 PBAGA Pilot Bracket 24 RMH 120 00574 Damper Clamp RMH 120 00100 25 26 27 1 0 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RMH...

Страница 25: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 26: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 27: ...________________________________________ ______________________________________________________ ______________________________________________________ _________________________________________________...

Страница 28: ...n misuse abuse hostile environments or improper installation repair or alteration acts of God such as fire flood hurricanes and tornadoes gas cylinders propane tanks or other fuel deliverysystems incl...

Отзывы: