iMX RT1062 OEM Developer’s Kit - User’s Guide
Page 19
Copyright 2019 © Embedded Artists AB
J6 allows measuring the internal 1.8V supply to the EcoXiP flash by measuring the voltage
drop over a 20 milliohm resistor.
Figure 14 – Location of iMX RT1052/1062 OEM Board Current Measurement Pads
4.4
SP2c: VBAT Powering
The picture below illustrates where the VBAT input connector is (J2) and where the current can be
measured over a 1 kohm resistor, J26. The arrow indicates the current flow direction.
Figure 15 – Location of VBAT Connector and VBAT Current Measurement Pads
VBAT Current Measurement
J26
Measure current over a 1kohm resistor
VBAT Input
J2
GND (top)
VBAT (bottom)
J1 - DCDC_IN current
over 20 milliohm
J2 - VDD_SOC_ON current
over 20 milliohm
J3 - VDD_HIGH_IN
current over 20 milliohm
J4 -VDD_SNVS_IN
current over 1ohm
J5 - VDD_ADC_3P3
current over 20 milliohm
J6 - 1.8V EcoXiP current
over 20 milliohm