the vibration of the compressor from interfering with the dryer’s operation. 

3.Mount dryer on firm level surface. 

4.Automatic drain outlet should be connected to the plant drainage system in order 

to prevent condensate from polluting plant.  

5. For typical placement in a compressed air system, see drawing  back. 

 

 

 

 

 

 

 

 

 

Typical Piping connection 

        Three  -valve bypass line should be installed before the dryer air inlet valve 

and after the dryer air outlet valve. This bypass valve always be install to permit 

the continued use of the plant compressed air system during any dryer 

maintenance or servicing operations. 

 

Power and electrical connections 

1. Be sure that voltage to unit is as marked on unit serial number tag. 

2. Range of voltage fluctuation will not exceed 10% of rated voltage. 

μ  

Filter

(1 )

Refrigerated Dryer

 Filter

(1 )

μ  

μ  

 

 Filter

(0.01 )

Air compressor

Aftercooler

Receiver

Separator

(3  )

μ  

μ  

Dew point:3-10°
Oil:0.003ppm w/w

Solid:<0.01

C

Temperature:<45°
Oil:5ppm w/w

Solid:<3

μ  

Dew point:3-10°
Oil:1ppm w/w

Solid:<1

C

μ  

C

Содержание EDRYHT0028

Страница 1: ......

Страница 2: ...AIR DRYER INSTRUCTION MANUAL 0 Contents GENERAL SAFETY INFORMATION 1 READ PRIOR TO STARTING THIS EQUIPMENT 1 DESCRIPTION 2 INSTALLATION 3 OPERATION 5 MAINTENANCE 6 FLOW SCHEMATIC 7 TROUBLESHOOTING 8...

Страница 3: ...READ PRIOR TO STARTING THIS EQUIPMENT 1 This equipment has been thoroughly checked packed and inspected before leaving out plant 2 This equipment is shipped to accommodate a forklift truck When insta...

Страница 4: ...duces product contamination and increases productivity Working flow Compressed air saturated with water vapor enters the dryer and is pre cooled by the outgoing refrigerated air in an air to air heat...

Страница 5: ...refrigerant reduces to a low pressure low temperature mixture of liquid and vapor after passing through the thermostatic expansion valve and evaporator as it takes heat from the compressed air The lo...

Страница 6: ...efore the dryer air inlet valve and after the dryer air outlet valve This bypass valve always be install to permit the continued use of the plant compressed air system during any dryer maintenance or...

Страница 7: ...nes for a few minutes to remove welding slag Start up 1 Check the low refrigeration pressure gauge it should indicate higher than 0 25MPa 2 If the voltage is at normal range open electric control box...

Страница 8: ...ter 10 minutes Shutdown Close the dryer air inlet valve and press the control button to shut then disconnect the power and close the water supply valve MAINTENANCE Air cooled condenser Ambient air sho...

Страница 9: ...l bolt and detach the shell take filter core out and clean it with brush and water d Reassemble the core and the shell Then open the manual valve ahead of drain Electric apparatus Check parts in the e...

Страница 10: ...itch improperly set Set properly Air cooled models Dirty clogged condenser fins obstructed air flow across condenser Clean condenser and check for free air flow Too much refrigerant Let out excessive...

Страница 11: ...functioning properly drain troubleshooting a Manual valve not open b Drain jam or damage Drain line higher than drain condensate outlet Open manual valve Clean and replace drain Install condensate li...

Отзывы: