AIR DRYER INSTRUCTION MANUAL

 

condensed moisture, oil and solids are separated from the compressed air and 

discharged from the system by an automatic condensate drain trap. The cold 

compressed air, enters the shell side of pre-cooler. By removing heat from the 

incoming air, the outgoing air is reheated. 

In the refrigeration system, the compressor compresses low temperature, 

low-pressure refrigerant into high temperature, high-pressure gas. The 

compressed refrigerant gas flows through the discharge line to a condenser, where 

the gaseous refrigerant is condensed into a high-pressure liquid, by exchanging 

heat to the cooling airflow. The high-pressure liquid refrigerant reduces to a low 

pressure, low temperature mixture of liquid and vapor after passing through the 

thermostatic expansion valve and evaporator as it takes heat from the compressed 

air. The low-pressure refrigerant gas leaves the evaporator and flows to the liquid 

refrigerant accumulator, ensuing that only gas is returned to compressor. The 

accumulator prevents liquid refrigerant from entering the compressor and causing 

severe damage to the compressor. Refrigerant travels through the suction line to 

the compressor where the refrigeration cycle again starts. 

 

INSTALLATION 

 Mounting

 

1. A dry, well-ventilated area is the best location for installation of the dryer. It 

also should be in an area where the ambient temperature will not exceed 40

°

C or 

fall below 2

°

C. 

2. A dryer should be kept at a distance from the air compressor in order to prevent 

Содержание EDRYHT0028

Страница 1: ......

Страница 2: ...AIR DRYER INSTRUCTION MANUAL 0 Contents GENERAL SAFETY INFORMATION 1 READ PRIOR TO STARTING THIS EQUIPMENT 1 DESCRIPTION 2 INSTALLATION 3 OPERATION 5 MAINTENANCE 6 FLOW SCHEMATIC 7 TROUBLESHOOTING 8...

Страница 3: ...READ PRIOR TO STARTING THIS EQUIPMENT 1 This equipment has been thoroughly checked packed and inspected before leaving out plant 2 This equipment is shipped to accommodate a forklift truck When insta...

Страница 4: ...duces product contamination and increases productivity Working flow Compressed air saturated with water vapor enters the dryer and is pre cooled by the outgoing refrigerated air in an air to air heat...

Страница 5: ...refrigerant reduces to a low pressure low temperature mixture of liquid and vapor after passing through the thermostatic expansion valve and evaporator as it takes heat from the compressed air The lo...

Страница 6: ...efore the dryer air inlet valve and after the dryer air outlet valve This bypass valve always be install to permit the continued use of the plant compressed air system during any dryer maintenance or...

Страница 7: ...nes for a few minutes to remove welding slag Start up 1 Check the low refrigeration pressure gauge it should indicate higher than 0 25MPa 2 If the voltage is at normal range open electric control box...

Страница 8: ...ter 10 minutes Shutdown Close the dryer air inlet valve and press the control button to shut then disconnect the power and close the water supply valve MAINTENANCE Air cooled condenser Ambient air sho...

Страница 9: ...l bolt and detach the shell take filter core out and clean it with brush and water d Reassemble the core and the shell Then open the manual valve ahead of drain Electric apparatus Check parts in the e...

Страница 10: ...itch improperly set Set properly Air cooled models Dirty clogged condenser fins obstructed air flow across condenser Clean condenser and check for free air flow Too much refrigerant Let out excessive...

Страница 11: ...functioning properly drain troubleshooting a Manual valve not open b Drain jam or damage Drain line higher than drain condensate outlet Open manual valve Clean and replace drain Install condensate li...