HULK Power

4

Always make sure that the 

compressor power switch is in the 

OFF position before performing any maintenance 

or plugging the compressor into a power supply.

7. 

 AIR FILTER -

Ensures the air being pressurized is free of 

contaminants and reduces the amount of noise 

the pump generates.

8. 

OUTPUT AIR PRESSURE GAUGE -

Shows the pressure of the air as it leaves the 

compressor.

9. 

HANDLE - 

Convenient, rubber gripped handle allows for 

easy transport of your air compressor.

10. 

AIR REGULATOR - 

The air regulator controls the output air 

pressure. Turn regulator clockwise to increase 

air pressure, counter-clockwise to decrease air 

pressure.

11. 

AIR COUPLER - 

Convenient brass quick-disconnect air coupler 

allows for fast easy connection to an air hose.

Safety Information

This manual contains very important information to

know and understand. This is provided for SAFETY

and to PREVENT EQUIPMENT PROBLEMS. To help 

understand this information, observe the following:

Danger indicates an imminently 

hazardous situation which, if not 

avoided, will result in death or serious injury.

Warning indicates a potentially 

hazardous situation which, if not 

avoided, could result in death or serious injury.

Caution indicates a potentially 

hazardous situation which, if not 

avoided, may result in minor or moderate injury.

Notice indicates important information, 

that if not followed, may cause damage 

to equipment.

  Read all manuals included with this 

product carefully. Be thoroughly 

familiar with the controls and the 

proper use of the equipment.

CALIFORNIA PROPOSITION 65

This product or its power cord 

may contain chemicals known to 

the State of California to cause cancer and birth 

defects or other reproductive harm. Wash hands 

after handling.

NOTICE

DANGER

WARNING

CAUTION

NOTICE

MANUAL

WARNING

Basic Guidelines

1.  Allow only trained, authorized persons who 

have read and understood these operating 

instructions to use this compressor. Failure 

to follow the instructions, procedures and 

safety precautions in this manual can result in 

accidents and injuries.

2.  NEVER start or operate the compressor 

under unsafe conditions. Tag the compressor, 

disconnect and lock out all power to it to 

prevent accidental start-up until the condition 

is corrected.

3.  Install, use and operate the compressor only 

in full compliance with all pertinent OSHA 

regulations and all applicable Federal, State & 

Local Codes, standards and regulations.

4.  NEVER modify the compressor and/or 

controls in any way.

5. 

Keep a fi rst aid kit in a convenient place. Seek 

medical assistance promptly in case of injury. 

Avoid infection by caring for any small cuts 

and burns promptly.

Breathable Air

1.  NEVER use air from this compressor for 

breathable air except in full compliance with 

OSHA Standards 29 CFR 1910 and any other 

Federal, State or Local codes or regulations.

Death or serious injury can result 

from inhaling compressed air 

without using proper safety 

equipment. See OSHA standards 

on safety equipment.

2.  DO NOT use air line anti-icer systems 

in air lines supplying respirators or other 

equipment used to produce breathable air. 

DO NOT discharge air from these systems in 

unventilated or other confi ned areas.

Pressurized Components

1.  This equipment is supplied with a ASME 

designed pressure vessel protected by an 

ASME rated relief valve. Pull the ring before 

each use to make sure the valve is functional. 

DO NOT attempt to open valve while the 

machine is under pressure.

2.  Improper maintenance could lead to the air 

tank bursting or exploding.
3.  Drain air tank after each use or 

daily to prevent moisture buildup in the 

air tank. Rust can weaken the air tank 

and cause leaks or bursting. If rust is 

detected, replace tank immediately. 

4.  Do not attempt repairs to the air tank by 

welding, drilling or other modifi cations. Such 

modifi cations may weaken the air tank and 

cause a hazardous condition.

DANGER

Содержание 815002013978

Страница 1: ...ufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the po...

Страница 2: ...on 5 Area 5 Electrical Safety 5 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 7 Power Requirements 7 Grounding Instructions 7 Connect to power source 8 Getting Started 8 Assem...

Страница 3: ...ld up Safety Valve is preset at factory Do not attempt to make any adjustments to the safety valve Periodically pull the ring on the safety WARNING The safety valve automatically relieves valve end to...

Страница 4: ...persons who have read and understood these operating instructions to use this compressor Failure to follow the instructions procedures and safety precautions in this manual can result in accidents and...

Страница 5: ...compressor for maintenance access and adequate airflow WARNING CAUTION Mount unit leaving a minimum of 15 inches 38 cm of clearance 3 Use shims to level compressor if installation area is not flat Th...

Страница 6: ...e in horseplay with air hoses as death or serious injury may result 7 Make sure to provide adequate ventilation while operating the compressor If combustible WARNING substances are spilled clean up im...

Страница 7: ...ust be repaired 10 Check for damage Check your tool regularly If part of the tool is damaged it should be carefully inspected to make sure that it can perform its intended function correctly If in dou...

Страница 8: ...nsure that is working properly Pull the ring on the safety valve before each use to make sure the valve is functional Depending on the CFM draw of the tools being operated your new air compressor can...

Страница 9: ...2 Check that the pressure switch is pointed up in the OFF position fig 9 0 3 Ensure that the power supply you are going to use is operating normally 4 Insert the power supply cord into the power supp...

Страница 10: ...ove the pressure switch clockwise to the OFF position fig 9 0 2 Unplug the compressor from the electical power 3 If not draining the tank reduce tank pressure through the air hose 4 Drain the tank by...

Страница 11: ...e un loader valve plug and clean the valve seal If damaged replace seal and re install Compressor stopped and will not re start 1 Thermal overload protector has engaged due to motor overheat ing 1 Che...

Страница 12: ...2 31 Self tapping screw 4 32 Fan 2 33 Outside spring 2 34 Crank throw 2 35 Stator 1 36 Rotor 1 37 Bearing 2 No Description Qty 38 Outside spring 2 39 Capacitor 1 40 Bolt 2 41 Capacitor cover 1 42 Bol...

Страница 13: ...13 HP15P005SS man v 171212 Air Compressor Schematic Drawing...

Страница 14: ...nty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to persons o...

Страница 15: ...15 HP15P005SS man v 171212 Air Compressor...

Страница 16: ...16 HULK Power...

Страница 17: ...nt s curitaire Cependant les op rateurs et les personnes charg es de l entretien sont responsables du maintien de la s curit Toutes les pr cautions de s curit sont incluses pour fournir une ligne dire...

Страница 18: ...e 21 S curit lectrique 22 Op ration 22 R gles de s curit 22 Pr cautions sur l outil pneumatique 23 Alimentation de la source 24 Exigences d alimentation 24 Instructions de mise la terre 24 Raccordemen...

Страница 19: ...ger l quipement et des blessures ventuelles 2 R SERVOIR r servoir de deux gallons 7 6 litres 3 PATTES DE CAOUTCHOUC r duit les vibrations et les mouvements du compresseur ATTENTION 4 SOUPAPE DE S CURI...

Страница 20: ...indique une situation dangereuse imminente qui si elle n est pas vit e entra nera la mort ou des blessures graves Attention indique une situation potentiellement dangereuse qui si elle n est pas vit e...

Страница 21: ...rateurs et autres personnes autour du compresseur et de DANGER ses commandes sont conformes toutes les r glementations codes et normes OSHA f d raux provinciaux et locaux applicables aux quipements d...

Страница 22: ...le moteur du compresseur 7 Assurez vous d installer des disjoncteurs et des fusibles de taille appropri e DANGER DANGER 8 L appareil doit tre correctement mis la terre NE PAS connecter le fil de terre...

Страница 23: ...uits chimiques de l huile etc ATTENTION ATTENTION 13 V rifiez l tat des tuyaux avant chaque utilisation N utilisez pas de tuyau endommag Si le tuyau est endommag remplacez le imm diatement 14 Lire et...

Страница 24: ...ant alternatif monophas AC 120 volts 60 Hz correctement connect s avec un disjoncteur retard de 15 amp res Il est recommand qu un lectricien qualifi v rifie la TENSION R ELLE au r ceptacle dans lequel...

Страница 25: ...allation et localisation Placez le compresseur dans un endroit propre sec et bien ventil Le compresseur doit tre plac 12 ou 18 pouces 30 45 cm des murs ou toute autre obstruction qui interf rerait ave...

Страница 26: ...allez utiliser fonctionne normalement 4 Ins rez le cordon d alimentation dans la prise d alimentation 5 Mettez le pressostat sous tension d placez le levier vers la position AUTO fig 9 1 6 Sur la jau...

Страница 27: ...inhabituels 2 Assurez vous que tous les crous et boulons sont serr s Apr s chaque utilisation goutter la condensation du r servoir d air Mensuel Inspectez le syst me d air pour les fuites en appliquan...

Страница 28: ...eut provoquer une surchauffe du moteur Laissez le mo teur refroidir 2 Enroulement du moteur serait brul 2 Contacter le service la client le Le moteur ne d marre pas et fait un bourdonnement Condensate...

Страница 29: ...x d fauts caus s directement ou indirectement par une mauvaise utilisation un abus une n gligence ou des accidents des r parations ou des modifications et le manque de maintenance HULK ne sera pas res...

Страница 30: ...is autotaraudeuse 4 32 Ventilateur 2 33 Ressort ext rieur 2 34 Coude de vilebrequin 2 35 Stator 1 36 Rotor 1 37 Roulement billes 2 No Description Qt 38 Ressort ext rieur 2 39 Condensateur 1 40 Boulon...

Страница 31: ...31 HP15P005SS man v 171212 HULK Power Dessin sch matique...

Страница 32: ...32 Compresseur air...

Отзывы: