1. IMPORTANT SAFETY INSTRUCTIONS

The  user  guide  you  are  holding  includes  essential  information  on  the  safety  measures  to  be  implemented  for 

installation and start-up. Therefore, the installer as well as the user must read the instructions before beginning 

installation and start-up. Keep this manual for future reference.

The  pump  should  be  installed  according  to  your  local  electrical  installation  ordinances  and  regulations.  Only 

qualified, licensed personnel should install the pump and the wiring.

This  appliance  cannot  be  used  by  persons  (including  children)  with  reduced  physical,  sensor y  or  mental 

capabilities  or  lack  of  experience  and  knowledge  unless  they  have  been  given  super vision  or  instruction 

concerning use of the appliance in a safe way and understand the hazards involved. Children must not play with 

the appliance.

IMPORTANT SAFETY INSTRUCTIONS    P4

Correct disposal of this product

This symbol on the product, or in its packaging, indicates that this product 

may not be treated as household waste. Instead, it should be taken to the 

appropriate  waste  collection  point  for  the  recycling  of  electrical  and 

electronic  equipment.  By  ensuring  this  product  is  disposed  of  correctly, 

you will help prevent potential negative consequences for the environment 

and human health, which could other wise be caused by the inappropriate 

waste  handling  of  this  product.  For  more  detailed  information  about  the 

recycling of this product, please contact your local council, your household 

waste disposal ser vice, or the shop where you purchased the product.

2. INSTALLATION

1. Install the pump as close to the pool as possible, preferably in a dr y, well ventilated area away from direct sun 

light. Protect the pump from excessive moisture.

2. Place the pump as close to the water source as possible, so that the suction pipe is short, straight and direct

to  reduce  the  friction  loss.  Don't  install  the  pump  at  more  than  10ft  (3  meters)  of  geometrical  height  from 

water level. 

3. Before installing the pump, make sure that the surface is solid, elevated, rigid and vibration free.

4. Secure the pump to the base with screws or bolts to limit the vibration and the stress on the pipe or the joints.

5. Leave enough space for gate valves in suction and discharge piping, if required.

6. Connect the suction and discharge pipe to the outlet and inlet of the swimming pool.

7. Make sure that floor drainage is adequate to prevent flooding.

8. 

This  pump  must  be  equipped  with  an  isolating 

transformer  or  through  a  residual  current  device 

(RCD)  having  a  rated  residual  operating  current  not 

exceeding 30 mA.

9.  Make  sure  that  the  pump  and  piping  are  accessible 

for ser vicing.

Note: The pump suction and discharge connections are 

mounded  in  thread  stops,  DO  NOT  tr y  to  screw  the 

pipe beyond these stops.

15. REPLACEMENT PARTS

Key No.

Part No.

Description

QTY

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

18

19

20

21

22

01021143

01041057

02010253

01112080

89023801

01021144

89021307

02010245

01112081

89020719

01311058

04015065

02010246

01021145

89020720

03011075

04020140

01112082

02010211

01031027

01321032

89023901

01041061

Nut for lid

Transparent Lid

O-Ring for Lid

Basket

1.5" Union

Pump Body

Drain Plug with O-ring

Diffuser

Screw for impeller with O-Ring

O-Ring for Flange

Flange

M8 x 35 Screw with Washer for Motor

M8 x 30 Screw

Base

O-Ring for Diffuser

Impeller For SPV150 & EPV150

3/4

Mechanical seal (EPH/EPV/SPH/SPV)

SPV150 TYC-71L Motor

Arch Cushion for Base

Fan

Fan Cover

Programmable Controller for SPV150

Transparent Lid for Programmable Controller

1

1

1

1

2

1

2

1

1

1

1

1

1

1

4

4

1

1

1

1

1

1

1

P19    REPLACEMENT PARTS

20

1

2

3

4

5

8

9 10 11 12

13 14

15

21

22

16

7

18

6

17

19

Содержание SPV Series

Страница 1: ...MANUAL SUPER POWER VARIABLE SPEED PUMP With Wi Fi AND MODBUS OPTIONS NSF only apply for NSF version Model SPV Series SAA STRIVE FOR CLEAR WATER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD EMPU210...

Страница 2: ...mmary of Emaux Claim Process in 3 steps 1 Claim Customer contacts Emaux salesperson and provides completed details of the claim which includes 1 Information about the failed product such as the part n...

Страница 3: ...erate under high pressure When any part of the circulating system i e lock ring pump filter valves etc is serviced air can enter the system and become pressurized Filter tank Lid and pre filter cover...

Страница 4: ...Entrapment or entanglement hair is pulled into and or wrapped around the grate of the drain cover 4 Mechanical Entrapment the bather s jewelry or clothing gets caught in the drain or the grate 5 Evisc...

Страница 5: ...ure 2 Place the pump as close to the water source as possible so that the suction pipe is short straight and direct to reduce the friction loss Don t install the pump at more than 10ft 3 meters of geo...

Страница 6: ...Running speed and power rating display 3 Pre set Speed 3 pre set running speeds 4 Function settings Real time clock 3 pre set speeds 2 schedule settings NO flow self priming settings 5 Error display O...

Страница 7: ...re Version Su00x Reset RESET Title Value Operation Light Start Stop Increase Page Up Decrease Page Down Mode Setting Preset Speed 1 Preset Speed 2 Preset Speed 3 Quick Setting Quick Setting Quick Sett...

Страница 8: ...ble and disable switch at the end of each setting to turn it ON or OFF 5 Freeze protection default temperature is 4 degree C in 4 or 8 hours running in setting speed 6 To do any change touch save to s...

Страница 9: ...ect connection is a ONE To ONE connection without access Home Network It is just like a private controller It can be connected and control by mobile phone tablet PC laptop top or any Wi Fi enable devi...

Страница 10: ...r details and all lights will start flashing Press Run shortly at the error menu to auto recover the variable speed driver keep the driver Off 10 ERRORS DESCRIPTION 10 1 COMMUNICATION ERROR If the com...

Страница 11: ...other When there is an error the variable speed driver will restore the settings to those before the error The priority setting is still applicable P13 SYSTEM RESET TO FACTORY DEFAULT SETTING 7 SYSTE...

Страница 12: ...ation interface for external automation controller It is not for domestic user access purpose It is an always ready to interface for external automation control The pin assignment is 1 A and 2 B The w...

Отзывы: