WARNINGS AND SAFETY INSTRUCTIONS
GENERAL WARNING

This  instruction  contain  general  caution  information  for  use  in  Pool  and  SPA  pump  installation  application. 

Specified Pump model function should be refer to particular manual. Components such as the filtration system, 

pumps and heater must be positioned so as to prevent their being used as means of access to the pool by young 

children.

This  appliance  should  be  installed  by  qualified  electrical  personnel  in 

accordance  with  National  Electrical  Code  and  all  applicable  local  codes 

and  ordinances.  Hazardous  voltage  can  shock ,  burn,  and  cause  death  or 

serious property damage. DO NOT use an extension cord to connect unit 

to electric supply to reduce the risk of electric shock .

1

The pump should be permanently connected to an individual circuit breaker.

2

Pump  must  be  connected  to  a  residual  current  device  (RCD)  having  a  rated  residual  operating  current  not 

exceeding 30 mA or receptacle with ground fault circuit interrupt (GCFI). 

3. Electrical grounding must be connected before connecting to electrical power. Failure to ground all electrical 

equipment can cause serious or fatal electrical shock hazard. 

4

Bonding:  Use  at  least  #8  AWG  (#6  AWG  for  Canada)  a  solid  copper  conductor,  run  a  continuous  wire  from 

external bonding lug (if available) to the pressure wire connector provided on the electrical equipment and to 

all metal parts of swimming pool, spa, or hot tub, and metal piping (except gas piping), and conduit within 1.5 

m (5 ft) of inside walls of swimming pool, spa, or hot tub.

5

Never  open  the  inside  of  the  drive  motor  enclosure.  There  is  a  capacitor  bank  that  holds  a  mains  supply 

voltage  charge  even  when  there  is  no  power  to  the  unit.  The  voltage  should  be  referred  to  the  individual 

pump operation voltage. 

6

The  pump  is  capable  of  high  flow  rates;  use  caution  when  installing  and  programming  to  limit  pumps 

performance only. 

7

Switch OFF pump power before ser vicing and disconnecting the main circuit to the pump.

8

Never change the filter control valve position while the pump is running.

RISK OF ELECTRICAL SHOCK

COMPRESS AIR HAZARDOUS

This system enclosed pre-filter / filter and become pressurized. 

Pressurized air can cause the Lid to separate which can result in serious 

injur y or death.

Pool and spa circulation systems operate under high pressure. When any 

part of the circulating system (i.e. lock ring, pump, filter, valves, etc.) is 

ser viced, air can enter the system and become pressurized. Filter tank Lid and pre-filter cover must be properly 

secured to prevent violent separation. Place pre-filter / filter air relief valve in the open position and wait for all 

pressure in the system to be relieved before remove the lib to access the basket for cleaning. 

HYPERTHERMIA

SPA  water  temperature  excess  38°C  (104°F)  may  be  injurious  to  health.   

Measure water temperature before entering SPA.

Hyperthermia occurs when the internal temperature of the body reaches 

a level several degrees above the normal body temperature of 98.6 °F (37 

°C). The symptoms of hyperthermia include drowsiness, lethargy, and an 

increase in the internal temperature of the body. 

WARNINGS AND SAFETY INSTRUCTIONS    P2

Problem description

Possible causes

Leakage of water at the shaft

Shaft seal requires replacement

Low pump capacity

1. Valve in the suction or discharge line partly closed

2. Suction or discharge line partly plugged

3. Suction or discharge line too small

4. Plugged basket in skimmer or hair and lint strainer

5. Dirty filter

6. Impeller clogged

High pump pressure

1. Discharge vale or inlet fittings closed too much

2. Return lines too small

3. Dirty filters

Noisy pump and motor

1. Plugged basket in skinner or hair in lint strainer

2. Worn motor bearings

3. Valve in suction line partly closed

4. Suction line partly plugged

5. Vacuum hose plugged or too small

6. Pump not supported properly

Air bubbles at inlet fittings

1. Leakage of air into the suction line in connections or valve stem

2. Cover gasket of hair and lint strainer needs cleaning

3. Low water level in the pool

Note:  If  the  above  recommendations  of  this  manual  do  not  solve  your  particular  problem(s),  please  contact  your 

local ser vice agent for further assistance.

P21    WARRANTY POLICY

18. WARRANTY POLICY

EXTENDED

 

WARRAN TY FOR SPECIFIC PRODUCTS

(OFFERED

 

FROM

 

DATE

 

OF INVOICE)

.

Product

Warranty

 

Period

Filters

 & 

Filter

 

Systems

 

2

 

years

 

Pumps

 

1

 

year

 

Underwater

 

Lights

 

1

 

year

 (

bulbs

 

90

 

days

)

 

Ladders

 

1

 

year

 

Control

 

devices

 

1

 

year

 

Heat

 

Pumps

 & 

Heat

 

Exchangers

 

1

 

year

 

Salt

 

Chlorinators

 & 

UV Systems

1

 

year

 

(

2

 

years

 

for

 

cell

 

material

)

Pool

 

Fittings

 

1

 

year

 

Cleaning

 

Equipment

 

All

 

others

1

 

year

 

Emaux  manufactures  its  products  with  the  highest  standard  of  workman  ship,  using  the  best  materials  available 

through state of the art process. Emaux proudly warrants its products as follows:

Содержание SPV Series

Страница 1: ...MANUAL SUPER POWER VARIABLE SPEED PUMP With Wi Fi AND MODBUS OPTIONS NSF only apply for NSF version Model SPV Series SAA STRIVE FOR CLEAR WATER www emauxgroup com EMAUX WATER TECHNOLOGY CO LTD EMPU210...

Страница 2: ...mmary of Emaux Claim Process in 3 steps 1 Claim Customer contacts Emaux salesperson and provides completed details of the claim which includes 1 Information about the failed product such as the part n...

Страница 3: ...erate under high pressure When any part of the circulating system i e lock ring pump filter valves etc is serviced air can enter the system and become pressurized Filter tank Lid and pre filter cover...

Страница 4: ...Entrapment or entanglement hair is pulled into and or wrapped around the grate of the drain cover 4 Mechanical Entrapment the bather s jewelry or clothing gets caught in the drain or the grate 5 Evisc...

Страница 5: ...ure 2 Place the pump as close to the water source as possible so that the suction pipe is short straight and direct to reduce the friction loss Don t install the pump at more than 10ft 3 meters of geo...

Страница 6: ...Running speed and power rating display 3 Pre set Speed 3 pre set running speeds 4 Function settings Real time clock 3 pre set speeds 2 schedule settings NO flow self priming settings 5 Error display O...

Страница 7: ...re Version Su00x Reset RESET Title Value Operation Light Start Stop Increase Page Up Decrease Page Down Mode Setting Preset Speed 1 Preset Speed 2 Preset Speed 3 Quick Setting Quick Setting Quick Sett...

Страница 8: ...ble and disable switch at the end of each setting to turn it ON or OFF 5 Freeze protection default temperature is 4 degree C in 4 or 8 hours running in setting speed 6 To do any change touch save to s...

Страница 9: ...ect connection is a ONE To ONE connection without access Home Network It is just like a private controller It can be connected and control by mobile phone tablet PC laptop top or any Wi Fi enable devi...

Страница 10: ...r details and all lights will start flashing Press Run shortly at the error menu to auto recover the variable speed driver keep the driver Off 10 ERRORS DESCRIPTION 10 1 COMMUNICATION ERROR If the com...

Страница 11: ...other When there is an error the variable speed driver will restore the settings to those before the error The priority setting is still applicable P13 SYSTEM RESET TO FACTORY DEFAULT SETTING 7 SYSTE...

Страница 12: ...ation interface for external automation controller It is not for domestic user access purpose It is an always ready to interface for external automation control The pin assignment is 1 A and 2 B The w...

Отзывы: