background image

4. MAINTENANCE

P7    MAINTENANCE

The FLEX Valve Actuator has 2 seals which require lubrication once a year. These seals are located at the

top and bottom of the actuator, where the shaft exits the actuator housing. Please follow the steps to

lubricate those seals:

Lubricate

1. Turn the actuator power OFF.

2. Remove the knob and the handle.

3. Spread a small amount of silicone base lubricant around the

actuator shaft where it enters the cover (See Fig. 6).

4. Reinstall the handle and knob, do not over-tighten.

5. Push down on the knob and handle to force the actuator

into manual override.

6. Spread a small amount of lubricant around the actuator shaft

where it protrudes from the bottom of the actuator.

7. Turn the handle once around to spread the lubricant.

8. Pull up on the handle and let it click into place.

9. Tighten the knob.

Fig. 6

To avoid electric shock which can result in property damage, severe injury or

death, disconnect power to the system at the main circuit breaker before

servicing.

To minimize the risk of injury and avoid damage to the equipment, use a properly

sized, listed Class 2 transformer for connection to the power supply.

WARNING

Relay1: Voltage connect control
Relay2: Turn control

White

Red

RELAY1

RELAY2

5. WIRING DIAGRAMS

Содержание 91609013

Страница 1: ...USER MANUAL FLEX VALVE ACTUATOR Installation and Operation manual EMVA22101240 Model FLEX Series...

Страница 2: ...ATION MANUAL P1 CONTENT 1 PRODUCT INTRODUCTION 2 SPECIFICATIONS 2 1 DIMENSION 3 INSTALLATION OPERATION 3 1 BASIC CAM SETTING 3 2 MOUNTING INSTRUCTIONS 3 3 TOGGLE SWITCH 3 4 ADVANCED CAM SETTING 3 5 SY...

Страница 3: ...permit children to use this product Improper installation and or operation will void the warranty P2 PRODUCT INTRODUCTION WARNING 1 PRODUCT INTRODUCTION Emaux FLEX Valve Actuator is a universal actuat...

Страница 4: ...ave to be changed depending on the location of the inlet port the port where water enters 3 way valve The Arrows are showing which screws required to change to long screws NOTE Port1 Port2 Port3 Port3...

Страница 5: ...ion Inlet Water enters port Basic Cam Setting Port Where Water Exits UPPER CAM LOWER CAM Port Port A standard 1 9 o clock 6 o clock 2 3 2 standard 12 o clock 12 o clock 1 3 3 6 o clock 3 o clock 1 2 B...

Страница 6: ...slot Fig 3 smallest tooth smallest slot Actuator Shaft Valve Diverter Factory default is matched with standard mount If the valve is connected in a standard installation there is no need to perform a...

Страница 7: ...lves to control the flow of water through the pool and spa If one is rotating in the opposite direction to the other the actuators have to be adjusted to bring them into Sync Simply flip the toggle sw...

Страница 8: ...knob and handle to force the actuator into manual override 6 Spread a small amount of lubricant around the actuator shaft where it protrudes from the bottom of the actuator 7 Turn the handle once aro...

Страница 9: ...a capacitor for possible peaks in the line and a switch controlling the tension of the red wire turn one way or white wire turn the other way In the following image you can see how the connection of...

Страница 10: ...to the actuator Check voltage between black common wire and each switch leg red white Toggle switch in the OFF position Flip toggle switch to ON 1 or ON 2 positions The motor has failed Replace motor...

Страница 11: ...1 Motor Synchronous with M4 x 8 screws and washers 2 2 1 10 E042812 Micro Switch Assembly With M2 3 x 10 screw 1 11 57200008 Switch Nest 2 12 E042813 Circuit Board with M4 x 12 screws 1 13 03011364 M4...

Страница 12: ...mance This Limited Warranty extends only to products purchased from Emaux authorized reseller This Limited Warranty does not extend to any product that has been damaged or rendered defective a as a re...

Страница 13: ......

Страница 14: ...YOUR PREMIER SUPPLIER EMAUX WATER TECHNOLOGY CO LTD www emauxgroup com...

Отзывы: