4. INSTALLATION
4.1 PIPING
1. Install the pump as close to the pool as possible, preferably in a dr y, well ventilated area away from direct
sunlight. Protect the pump from excessive moisture.
2. Place the pump as close to the water source as possible, so that the suction pipe is short, straight and direct
to reduce the friction loss. Don't install the pump at more than 10ft (3 meters) of geometrical height from
water level. Pump priming time for 3m (10ft) should be at least 7 minutes at 2900 RPM.
3. Before installing the pump, make sure that the surface is solid, elevated, rigid and vibration free.
4. Secure the pump to the base with screws or bolts to limit the vibration and the stress on the pipe or the joints.
5. Leave enough space for gate valves in suction and discharge piping, if required.
6. Connect the suction and discharge pipe to theoutlet and inlet of the swimming pool.
7. Make sure that floor drainage is adequate to prevent flooding.
8.
Make sure that the pump and piping are accessible for ser vicing.
INSTALLATION P6
Note: The pump suction and discharge connections have thread stops, DO NOT tr y to screw the pipe beyond
these stops.
The two sets of 3” union adaptors with 3” nut are universally designed for bot metric and imperial PVC pipe
connection.
4.2 ELECTRICAL WIRING
WARNING: This power pump requires a certified electrician or qualified
poor installer to ensure there is adequate protection between the pump
motor and mains power supply according to individual countr y’s safely
code.
1. The pump has to connect to circuit breaker to isolate the motor from the mains power for overload
protection. The circuit breaker rating should comply with the electrical specification of the pump’s working
voltage and power.
2. 3-phase motor require external three-phase motor starter or magnetic motor starter to control the motor on/
off.
3. To ensure the rotation of the pump, power up the motor for a second then off to check the rotation of the
motor fan or shaft. The fan or shaft will match the rotation arrow noted on the pump if wired correctly. Swap
either two connection (wired to U1, V1 or W1) if direction is revised.
4. The power supply must be equipment with a Residual Current Device (RCD) or Ground Fault Circuit Interrupt