AQ-10 Operating Instructions

  

 

    Page 6

 

 

 

 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

 

CAUTION: RISK OF ELECTRIC SHOCK. 

DO NOT OPEN 

 
 

 
 

 

 
 

WARNING:  Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective 

earthing connection. 
 

WARNING:  To prevent injury, this apparatus must be securely attached to the rack in accordance with the 
installation instructions. 

 
Read these instructions. 

 
Keep these instructions. 

 
Heed all warnings. 

 

Follow all instructions. 
 

Do not use this apparatus near water. 
 

Clean only with a dry cloth. 
 

Do not block any ventilation openings, install in 
accordance with the manufacturer’s instructions. 

 
Do not install near any heat sources, such as 

radiators, heat registers, stoves or other apparatus 
(including amplifiers) that produce heat. 

 
Protect the power cord from being walked on or 

pinched particularly at plugs, convenience receptacles 
and the pint where they exit from the apparatus. 

 

The mains circuit breaker shall remain readily 
accessible. 

 
Only use attachments/accessories specified by the 

manufacturer. 
 

Use only with the cart, tripod, bracket or table 
specified by the manufacturer, or sold with the 

apparatus. When a cart is used, use caution when 
moving the cart/apparatus combination to avoid injury 

from a tip over. 
 

Disconnect this apparatus during lightning storms or 
when unused for a long period of time. 

 

  Refer all servicing to qualified service personnel. 

Servicing is required when the

 

apparatus has been 

damaged in any way, such as if the power-supply cord 

or plug is damaged, liquid has been spilled or objects 
have fallen into the apparatus, the apparatus has been 

exposed to rain or moisture, does not operate normally, 

or has been dropped. 
 

Do not expose this equipment to dripping or splashing 
and ensure that no objects filled with liquids, such as 

vases, are placed on the equipment. 
 

To completely disconnect this equipment from the AC 
mains, disconnect the power cord from the mains circuit 

breaker. 
 

Where the amplifier is mounted in a rack and 
permanently connected to the mains, then the rack 

should be installed with a readily accessible connector 
or an ALL POLE circuit breaker with 3mm breaking 

distances. 
 

This unit is fitted with a 3-wire power cord. For safety 

reasons, THE EARTH LEAD SHOULD NOT BE 
DISCONNECTED IN ANY CIRCUMSTANCE. 

 
The cooling fans suck cool air in through the front and 

blow hot air out at the rear of the unit through the 
ventilating grills. The front and rear of the amplifier 

should have free exposure to the air (i.e. in a rack leave 
the front and rear doors off), with 2cm air gap at the 

sides and top. IF AIR IS NOT ALLOWED TO ESCAPE 
FROM THE REAR, OVER-HEATING WILL OCCUR. Take 

care when mounting other equipment in the same rack. 
 

The mains switch on the amplifiers only switches one 
pole of the mains supply, therefore for units with a 

detachable cord to be fully disconnected from the 

mains, the mains disconnect device (ie mains plug or 
mains coupler) should remain readily operable.  For 

units with a fixed mains lead the external all pole circuit 
breaker with 3mm breaking distances is the disconnect 

device and therefore the installation of the amplifier 
shall be carried out in accordance with all the applicable 

installation rules. 
 

 
 
 

 

The lightning flash with arrowhead 

symbol within an equilateral triangle is 
intended to alert the user to the presence 

of uninsulated “dangerous voltage” 
within the products enclosure that may 

be of sufficient magnitude to constitute a 
risk of electric shock to persons. 

The exclamation point within an 

equilateral triangle is intended to alert 
the user of important operating and 

maintenance (servicing) instructions in 
the literature accompanying the 

appliance. 

Содержание AQ-10

Страница 1: ...EM Acoustics Loudspeakers Building 74 Dunsfold Park Cranleigh Surrey GU6 8TB UK www emacoustics co uk AQ 10 amplifier User Manual v1 0...

Страница 2: ...AQ 10 Operating Instructions Page 2...

Страница 3: ...r Dynamic Amplifier Performance Measurements 10 Connecting To Your Amplifier Inputs 11 Connecting To Your Amplifier Speaker Outputs 12 Connecting To Your Amplifier Bridged Mono Operation 13 Operating...

Страница 4: ...8408990 Type Designation E100 and all OEM variants of this model are manufactured in accordance with EMC Directive 2004 108 EC in compliance with the following norm s or document s Technical Regulatio...

Страница 5: ...e It has been designed to meet demands for higher power and increased efficiency whilst still maintaining the renowned sonic qualities and unsurpassed reliability associated with our loudspeaker produ...

Страница 6: ...nd ensure that no objects filled with liquids such as vases are placed on the equipment To completely disconnect this equipment from the AC mains disconnect the power cord from the mains circuit break...

Страница 7: ...rempli des liquides comme les vases n est plac sur l quipement Pour compl tement d brancher cet quipement de la conduite principale de courant alternatif d branchez la corde de pouvoir du disjoncteur...

Страница 8: ...cord For safety reasons THE EARTH LEAD SHOULD NOT BE DISCONNECTED IN ANY CIRCUMSTANCE If ground loops are encountered consult the section on connecting your amplifier on page 11 The wiring colours are...

Страница 9: ...mm rack mounting systems ENSURE THERE IS ADEQUATE VENTILATION The cooling fans suck cool air in through the front and blow hot air out at the rear of the unit through the ventilating grills The front...

Страница 10: ...eed their RMS power rating The AQ 10 amplifier has been designed to match this requirement and can deliver huge levels of power for short durations In order to protect themselves and the loudspeakers...

Страница 11: ...The cable should still be twin core plus screen PIN1 Screen connected to the chassis of the unbalanced equipment or left disconnected at the unbalanced end PIN2 Hot signal PIN3 Cold ground 0V NOTE Th...

Страница 12: ...t be joined together as they are not both at ground potential Connecting them together will damage the amplifier and void the warranty As the currents involved are very high and to ensure best perform...

Страница 13: ...r channel pair C D The method is the same for both channel pairs Supply signal to Channel A or C input only and push in the appropriate rear panel switch marked BRG A B or BRG C D Use Channel A or C s...

Страница 14: ...subsonic or VHF levels 4 Attenuation Controls These are analogue controls allowing precise level settings Note that in bridged mono mode some controls may be inactive 5 Link LED This indicates if the...

Страница 15: ...spill water or other liquids into or on the unit and do not operate the unit while standing in liquid Do not block fan intake or rear ventilation outlets or operate the unit in an environment that cou...

Страница 16: ...4 Input XLR sockets Connect signal inputs to these sockets wired pin 2 hot 3 cold 1 ground For sensitivity and impedance of these inputs please see the specifications on page 18 5 Bridged mono switch...

Страница 17: ...st debris on the finger guards they can be cleaned with a dry paintbrush and a vacuum cleaner The casework of the amplifier may be cleaned with a lightly dampened cloth do not use any solvents as they...

Страница 18: ...t PCB PCB741 one link for each channel Channel A s link is number 1 channel B s is number 2 and so on The gain may be set to 26 32 factory default setting or 36dB Remember setting higher gain does not...

Страница 19: ...Boxed shipping 14 0 Additional Specifications Parameter Units AQ 10 Input Impedance Active Balanced Ohms 20k Input CMRR dB 60 SNR dB 105 Damping Factor 1kHz 8 ohms 400 Signal Limiters Present Yes Pro...

Страница 20: ...16 6 504 528 566 660 120 4 4 2 7 8 14 0 28 8 504 551 628 816 120 2 4 2 9 0 17 2 38 2 504 564 668 936 No Sig l Quiescent Light Crest Factor of 7 8 18dB Average Crest Factor of 4 8 14dB Heavy Crest Fact...

Отзывы: