![EM TEST EFT 500 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/em-test/eft-500-series/eft-500-series_manual-for-operation_2398491016.webp)
EM TEST
EFT 500 Series
Manual for Operation
V 2.00
16 / 21
4.
Technical data
4.1.
EFT Electrical Fast Transients Burst as per IEC 61000-4-4
Test Level
Open circuit
200V - 4400V ± 10%
Step 10V
Wave shape into a 50
Ω
load
100V – 2200V
Rise time tr
5ns ± 30%
Pulse duration td
50ns
±
30%
Wave shape into a 1000
Ω
load
200V – 4400V
Rise time tr
5ns ± 30%
Pulse duration td
35ns - 150ns
Source impedance
Zq = 50
Ω
± 20%
Polarity
positive / negative
Trigger
Trigger of bursts
AUTO, MANUAL, EXTERN
Synchronization
0° - 360°
Burst duration td
0.1ms - 999.9ms
Burst repetition rate tr
10ms - 9999ms
Spike frequency f
0.1kHz - 1000kHz
Test duration T
0:01 min - 99:59 min
Output
Direct via 50
Ω
coaxial connector
To connect ext. coupling devices
Coupling network
To L, N, PE all combinations
DUT power mains supply
AC 250 V / 16 A / 50/60 Hz
DC 250V/10A
Test routines
Quick Start
Immediate start, all parameters adjustable during a running test
Standard test as per
IEC 61000-4-4 level 1 ... level 5
Level X - Level Y
User test routines
Customized test routines
Voltage change after T by
∆
V
Frequency change after T by
∆
f
Frequency sweep in one single burst
Change duration after T by
∆
td
Change polarity after T
Statistical burst release
Synchronized at fixed angle
Safety
Safety circuit
Control input ( short circuit )
Design
as per IEC 1010, EN 61010
Interfaces
RS 232
serial, 1200 - 19200 Baud
IEEE
parallel, addresses 1-30
CN port
Control of CNE 503 for 3-ph testing
General data
Dimensions
19" / 3 HUE
Weight
approx. 8kg
Power supply
115V/230V +10/-15% 50/60Hz
Fuses
2 x T 1A slow blow