EM Test
CWS500 N2
User manual
V 3.00
11 / 38
4.2.
Quickstart
Easy and very fast operation for functions check and verification of the CWS 500N2.
Page 2
(Show Parameters)
Page 3
(Change)
Quickstart
Quickstart
Att
= 63,0 dB
f
=
109.500 MHz
Mod = AM 1kHz 80%
Att :
0.0 dB -
63.5 dB
f :
0.009 MHz -
400.0 MHz
Mod : OFF, AM 80%, AM 90%, Pulse
Att
f
Mod
START CHANGE
57.0
109.5
ON
F1
F2
F3
F4
F5
F6
F7
F1
F2
F3
F4
F5
F6
F7
Press
START
to begin testing.
Press
CHANGE
and the actual parameters can be changed. Selecting a parameter to change will display the
range.
The test begins by pressing
START
. The blinking parameter can be changed with the knob inc./dec.
Use the cursor keys (
) to select other parameters. By pressing
STOP
the test will be stopped and on the
last line of the display it will be indicated that the test has been stopped.
Page 3
(Operating)
Quickstart
Att
= 33,0 dB
f
=
109.500 MHz
Mod = AM 1kHz 80%
FPow = - 9.7 dBm
Mon = -56.9 dBm
Rpow = - 16.5 dBm
STOP
F1
F2
F3
F4
F5
F6
F7
Error messages:
Quickstart
Att
= 40,0 dB
f
=
109.500 MHz
Mod = off
FPow = +
6.6 dBm
Mon = -57.3 dBm
Rpow = +
6.8 dBm
Fpow to low
!
Message :
Fpow to low !
What happens : The amplifier does not supply the expected gain. The firmware checks the ratio between the
signal generator output and the Forward power. The reason can be an amplifier defect or an
internal error in the CWS 500N2. This message appears only when using internal amplifier.