Technical Data
Test Level:
Output Level
1 - 30Ve.m.f. after 6dB-attenuator
Output power
75W (nominal)
Output impedance
50 Ohm
max. VSWR
1:1.2 at all phase angles and at
max. power (without destruction)
Harmonic distortion
< 15dBc
(at max. power)
Test frequencies
Sinusoidal (CW)
9kHz - 250MHz
Frequency bands
9kHz - 9,999MHz
step: 1kHz
10MHz - 99,99MHz step: 10kHz
100MHz - 230MHz
step: 100kHz
In the menu QUICK START the step
size can be selected by the user
Modulation
Amplitude modulation
acc. to IEC 61000-4-6
80% <
±
5% and 1kHz <
±
10%
acc. to IEC 60601-1-2
80% <
±
5% and 2Hz
General
Amplitude modulation 80%
Frequencies 2Hz, 400Hz,1kHz
Pulse modulation
1Hz, 50% duty cycle
acc. to EN 50130-4
Measurements
Cal input (BNC)
RF voltmeter (rms) integrated,
measurement input for calibration
(V
max
= 3V
rms
)
LCD
On-line display of the test level and the
preselected frequencies.
Cal data
4 internal stores for calibration data.
ICD
Software for the upload and download of
Cal-files.