EM Acoustics EMS-51 Скачать руководство пользователя страница 6

Page 5 of 24 

 

 

EMS-51 User Manual 

v2 November 2019 

 

1.0 - Introduction 

Thank you for purchasing the highly acclaimed EMS-51 from EM Acoustics.  This product 
has been designed and rigorously tested to give you the utmost in sonic performance and 
many  years  of  reliable,  trouble-free  operation.    Please  take  the  time  to  read  this  user 
manual  thoroughly  to  ensure  you  get  the  best  performance  from  your  system  and  to 
ensure you set it up correctly and safely.  If you have any questions or are in any doubt 
whatsoever about any aspect of your new product, please do not hesitate to contact us 
directly or your local EM Acoustics representative. 

The EMS-51 is an extremely compact 2-way loudspeaker, intended for a wide variety of 
discreet  applications  –  from  theatrical  fills  and  delays  right  through  to  theme  park 
attractions. The extremely compact enclosure houses a 5” LF drive unit and a 1.1” soft 
dome HF drive unit, along with an extremely comprehensive passive crossover network.  
This means the EMS-51 exhibits flat frequency and phase responses without the need of 
external corrective processing. 

This manual contains all the information you should need on topics of set up, amplifier 
connection and basic service.  If you feel we have missed anything, or you have a question 
not covered by this manual, please visit our website 

www.emacoustics.co.uk

 and send us 

a message or give us a call – we’re only too happy to help. 

Unpacking 

Please take care when unpacking your loudspeaker system.  Once unpacked, please inspect 
each enclosure thoroughly for any transit damage and in the case of any damage please 
notify your carrier immediately.  It is the responsibility of you, the consignee, to instigate 
any claim.  Please retain all original packaging in case of future re-shipment. 

Содержание EMS-51

Страница 1: ...TECHNICAL SERVICES FOR EVENTS THEATRE MUSIC EXHIBITION FILM TV 01483 757211 HIRE STORMLTD CO UK WWW STORMLTD CO UK...

Страница 2: ...EMS 51 ultra compact two way passive fill loudspeaker Product User Manual v2 November 2019 L O U D S P E A K E R S R E D E F I N E D...

Страница 3: ...Stacking 9 Rigging and Suspension 9 Secondary Safeties 10 Safety Inspections 10 Material Damage from Magnetism 10 5 0 Rigging Mounting Options 11 5 1 EMS 51 Cabinet Overview 11 5 2 Using the YK 51h or...

Страница 4: ...over Cable Use 17 7 0 Servicing Information 18 7 1 EMS 51 Removing the grille 18 7 2 EMS 51 Removing the LF drive unit 19 7 3 EMS 51 Removing the HF drive unit 20 Appendix A Technical Specifications 2...

Страница 5: ...ctrical Safety EN60065 1993 RECYCLING This product and its packaging constitute the applicable product according to the WEEE directive Please ensure that at the end of the working life of this product...

Страница 6: ...through to theme park attractions The extremely compact enclosure houses a 5 LF drive unit and a 1 1 soft dome HF drive unit along with an extremely comprehensive passive crossover network This means...

Страница 7: ...9 mm ins 4 5 5 2kg 9 9 11 7lbs YK 51h Horizontal mounting yoke The YK 51h is a simple and effective means of mounting the EMS 51 in both temporary and permanent applications and is included with the E...

Страница 8: ...loaded for free from the AFMG website at http focus afmg eu and is currently available as a stand alone application for Windows XP or Higher only It can also be downloaded directly from the EM Acousti...

Страница 9: ...mum load capabilities as detailed in the appropriate user manuals or on the legend labels on the accessories themselves Ensure all additional accessories fasteners and secondary safeties are of an app...

Страница 10: ...roduct unless where specifically stated or any other loudspeaker system The use of EM Acoustics accessories with other manufacturers systems may compromise the safety standards and EM Acoustics is in...

Страница 11: ...st also be carried out Safety legislation and test inspection requirements will vary from country to country and as such it is the user s responsibility to ensure that local regulations are adhered to...

Страница 12: ...Page 11 of 24 EMS 51 User Manual v2 November 2019 5 0 Rigging Mounting Options 5 1 EMS 51 Cabinet Overview 1 Top Bottom M8 mounting point 2 Left Right M8 mounting point 1 2 1 2...

Страница 13: ...rientation of yoke Ensure that the washers are in the correct order form A flat in contact with the frame and then the spring washer between the flat washer and the locking knob Tighten the knobs on b...

Страница 14: ...rs provides a neat and flexible system that will encompass all requirements for the system to function correctly as well as providing user control for room EQ and system alignment 6 1 Amplifier and Pr...

Страница 15: ...orking well within its limits All of the DQ Series advanced system amplifiers can be used to power the EMS 51 The following table shows the maximum number of EMS 51 that can be connected per channel o...

Страница 16: ...ysical location differences between different elements of your system for example time aligning subwoofers to the main system The use of SMAART or similar can make this task a great deal simpler and f...

Страница 17: ...ate high low pass filter settings and limiters to get the best from your subwoofers Please refer to the DQ Series User Manual for detailed information on using the amplifiers and the System Engineer s...

Страница 18: ...edance Cables with a cross sectional area of less than 2 5mm2 should not be used Recommended maximum cable lengths are given below Conductor Area Maximum Recommended Cable Length 2 ohms 4 ohms 8 ohms...

Страница 19: ...ng a Pozidrive PZ2 screwdriver and then lift the grille clear of the cabinet 2 To replace the grille position the grille on the front of the EMS 51 and ensure the threaded fittings on the grille are l...

Страница 20: ...tion brown to LF positive blue to LF negative 4 To replace the drive unit ensure the 5 gasket is intact and complete replace if necessary Reconnect the cables to the drive unit note the polarity detai...

Страница 21: ...cess and disconnect the cables note the polarity for reconnection white to positive yellow to negative 4 To replace the drive unit ensure the gasket is intact and complete replace if necessary Reconne...

Страница 22: ...s per amp channel DQ6 4 DQ10 4 DQ20 4 Connectors 2 x Neutrik SpeakONTM NL4 Enclosure 12mm 1 2 multi laminate birch plywood rebated pinned and glued Finished in black or white textured paint Rigging Ha...

Страница 23: ...Page 22 of 24 EMS 51 User Manual v2 November 2019 FRONT LEFT RIGHT REAR TOP BOTTOM YK 51h HORIZONTAL YOKE 3mm STEEL ISOMETRIC YK 51v VERTICAL YOKE 3mm STEEL Appendix B Technical Drawings...

Страница 24: ...Page 23 of 24 EMS 51 User Manual v2 November 2019 Appendix C Spare Parts List Order Code Description 01A507 CAD 401 replacement 4 0 85 coaxial drive unit 04A049 RFG 41 replacement grille for EMS 41...

Страница 25: ...faced Returning your EM Acoustics loudspeaker Should your EM Acoustics loudspeaker develop a fault please return it freight prepaid in its original packaging along with proof of purchase to your local...

Отзывы: