EM Acoustics EMS-51 Скачать руководство пользователя страница 25

Page 24 of 24 

 

 

EMS-51 User Manual 

v2 November 2019 

 

Appendix D – Warranty Information 

Limited Warranty 

This EM Acoustics loudspeaker product is warranted to the original end-user purchaser and all subsequent 
owners for a period of five (5) years from the original date of purchase. 

Warranty Coverage 

This warranty covers defects in materials and workmanship.  It does not include: 

 

Damage or failure caused by accident, misuse, neglect, abuse or modification by any person other than an 
authorised EM Acoustics representative. 

 

Damage or failure caused by operating the loudspeaker product contrary to the instructions contained 
within this manual. 

 

Damage caused during shipment. 

 

Claims based on any misrepresentation by the seller. 

 

Products which contain anything other than the original components (or EM Acoustics factory supplied 
spare parts). 

 

Products on which the serial number has been removed, altered or defaced. 

 

Returning your EM Acoustics loudspeaker 

Should  your  EM  Acoustics  loudspeaker  develop  a  fault,  please  return  it  (freight  prepaid)  in  its  original 
packaging, along with proof of purchase to your local dealer or to:  

EM Acoustics (Returns Department), Building 19.11, Dunsfold Park, Cranleigh, Surrey, GU6 8TB, UK 

including a description of the suspected fault.  Serial numbers must be quoted in all correspondence relating 
to the claim.  EM Acoustics or its representatives are in no way liable for any loss or damage in transit, and 
hence it is recommended that the sender insure the shipment.  EM Acoustics will pay for return freight should 
the repair be covered under warranty. 

EM Acoustics’ liability is to the replacement or repair (at our discretion) of any defective components, and as 
such  are  not  liable  for  any  incidental  and  consequential  damages  including  (without  limitation)  injury  to 
persons, damage to property or loss of use. 

This warranty is exclusive and no other warranty is expressed or implied.  This warranty is also in addition 
to – and in no way detracts from – your statutory rights as a consumer. 

 

 

 

Содержание EMS-51

Страница 1: ...TECHNICAL SERVICES FOR EVENTS THEATRE MUSIC EXHIBITION FILM TV 01483 757211 HIRE STORMLTD CO UK WWW STORMLTD CO UK...

Страница 2: ...EMS 51 ultra compact two way passive fill loudspeaker Product User Manual v2 November 2019 L O U D S P E A K E R S R E D E F I N E D...

Страница 3: ...Stacking 9 Rigging and Suspension 9 Secondary Safeties 10 Safety Inspections 10 Material Damage from Magnetism 10 5 0 Rigging Mounting Options 11 5 1 EMS 51 Cabinet Overview 11 5 2 Using the YK 51h or...

Страница 4: ...over Cable Use 17 7 0 Servicing Information 18 7 1 EMS 51 Removing the grille 18 7 2 EMS 51 Removing the LF drive unit 19 7 3 EMS 51 Removing the HF drive unit 20 Appendix A Technical Specifications 2...

Страница 5: ...ctrical Safety EN60065 1993 RECYCLING This product and its packaging constitute the applicable product according to the WEEE directive Please ensure that at the end of the working life of this product...

Страница 6: ...through to theme park attractions The extremely compact enclosure houses a 5 LF drive unit and a 1 1 soft dome HF drive unit along with an extremely comprehensive passive crossover network This means...

Страница 7: ...9 mm ins 4 5 5 2kg 9 9 11 7lbs YK 51h Horizontal mounting yoke The YK 51h is a simple and effective means of mounting the EMS 51 in both temporary and permanent applications and is included with the E...

Страница 8: ...loaded for free from the AFMG website at http focus afmg eu and is currently available as a stand alone application for Windows XP or Higher only It can also be downloaded directly from the EM Acousti...

Страница 9: ...mum load capabilities as detailed in the appropriate user manuals or on the legend labels on the accessories themselves Ensure all additional accessories fasteners and secondary safeties are of an app...

Страница 10: ...roduct unless where specifically stated or any other loudspeaker system The use of EM Acoustics accessories with other manufacturers systems may compromise the safety standards and EM Acoustics is in...

Страница 11: ...st also be carried out Safety legislation and test inspection requirements will vary from country to country and as such it is the user s responsibility to ensure that local regulations are adhered to...

Страница 12: ...Page 11 of 24 EMS 51 User Manual v2 November 2019 5 0 Rigging Mounting Options 5 1 EMS 51 Cabinet Overview 1 Top Bottom M8 mounting point 2 Left Right M8 mounting point 1 2 1 2...

Страница 13: ...rientation of yoke Ensure that the washers are in the correct order form A flat in contact with the frame and then the spring washer between the flat washer and the locking knob Tighten the knobs on b...

Страница 14: ...rs provides a neat and flexible system that will encompass all requirements for the system to function correctly as well as providing user control for room EQ and system alignment 6 1 Amplifier and Pr...

Страница 15: ...orking well within its limits All of the DQ Series advanced system amplifiers can be used to power the EMS 51 The following table shows the maximum number of EMS 51 that can be connected per channel o...

Страница 16: ...ysical location differences between different elements of your system for example time aligning subwoofers to the main system The use of SMAART or similar can make this task a great deal simpler and f...

Страница 17: ...ate high low pass filter settings and limiters to get the best from your subwoofers Please refer to the DQ Series User Manual for detailed information on using the amplifiers and the System Engineer s...

Страница 18: ...edance Cables with a cross sectional area of less than 2 5mm2 should not be used Recommended maximum cable lengths are given below Conductor Area Maximum Recommended Cable Length 2 ohms 4 ohms 8 ohms...

Страница 19: ...ng a Pozidrive PZ2 screwdriver and then lift the grille clear of the cabinet 2 To replace the grille position the grille on the front of the EMS 51 and ensure the threaded fittings on the grille are l...

Страница 20: ...tion brown to LF positive blue to LF negative 4 To replace the drive unit ensure the 5 gasket is intact and complete replace if necessary Reconnect the cables to the drive unit note the polarity detai...

Страница 21: ...cess and disconnect the cables note the polarity for reconnection white to positive yellow to negative 4 To replace the drive unit ensure the gasket is intact and complete replace if necessary Reconne...

Страница 22: ...s per amp channel DQ6 4 DQ10 4 DQ20 4 Connectors 2 x Neutrik SpeakONTM NL4 Enclosure 12mm 1 2 multi laminate birch plywood rebated pinned and glued Finished in black or white textured paint Rigging Ha...

Страница 23: ...Page 22 of 24 EMS 51 User Manual v2 November 2019 FRONT LEFT RIGHT REAR TOP BOTTOM YK 51h HORIZONTAL YOKE 3mm STEEL ISOMETRIC YK 51v VERTICAL YOKE 3mm STEEL Appendix B Technical Drawings...

Страница 24: ...Page 23 of 24 EMS 51 User Manual v2 November 2019 Appendix C Spare Parts List Order Code Description 01A507 CAD 401 replacement 4 0 85 coaxial drive unit 04A049 RFG 41 replacement grille for EMS 41...

Страница 25: ...faced Returning your EM Acoustics loudspeaker Should your EM Acoustics loudspeaker develop a fault please return it freight prepaid in its original packaging along with proof of purchase to your local...