TDS meter malfunction

The display goes off after 
approx. 20 seconds.

The inlet value (IN) shows -
000-

The outlet value (OUT) shows 
-000-

The display remains empty, 
even after pressing the
 "POWER" button.

The display flutters, is diffi-
cult to read or contains illegi-
ble characters.

The display shows -ERR-

The resin seems to be used 
faster (increased TDS) than 
the water hardness calcu-
lated.

Pull the measuring 
device upward out 
of the holder.

First, loosen the 
metal housing

Loosen and remove 
the four metal 
screws on the 
back

Remove 
and replace 2 AA bat-
teries.

back side

This is not a malfunction; it automatically switches off to conserve the 
batteries. Press the "POWER" button again.

The sensor in the inlet has no measuring values or is defective. Use the 
flush valve to check whether the refill station is full of water. If this is 
the case and the malfunction persists, then the measuring device and 
sensor must be replaced.

Check the water meter to see whether the refill station is full of water. 
If this is the case, then this is not a malfunction, instead it is a correct 
measurement of the desalinated water. If it can be assumed that the 
cartridge is exhausted (due to the amount of treated water) and the 
display  remains  on  -000-,  then  the  measuring  device  should  be 
replaced along with the sensor.

Change batteries.

Change batteries

.

Measuring device malfunction. Reset by switching on and off quickly 
2-3 times until the display is normal again. Otherwise, remove and 
reinsert the batteries.

There probably is not a malfunction, instead the untreated water con-
tains dissolved solids (sulfate, nitrate, chloride) in addition to lime, 
which are removed and thus reduce the capacity. 
Otherwise there is a flow measurement malfunction (see below)

Malfunction

Batteriewechsel

Solution

Flow rate measurement device malfunction

The water meters appears to 
be too slow or do not run at 
all.

A fine sieve is installed in front of the outlet valve in order to prevent 
resin from leaking into the system from the apparatus due to an opera-
tion failure. If resin does leak out of the cartridge, it is caught in the fine 
sieve and interrupts the function of the armatures. Solution: Rinse and 
clean armatures out.

Содержание PUROTAP profi

Страница 1: ...al water circulationslead to corrosion and mineral deposits PUROTAP filters aggressive materials out of the water and enables trouble free operation Installation Function Operation Service Demineralis...

Страница 2: ...ing to the latest standards Connection The instruments Determining water hardness Calculating capacity Replacing ion exchanger resin TDS meter malfunction Changing batteries Flow rate measurement devi...

Страница 3: ...he filling apparatus Operating specifications must be adhered to according to this manual Local guidelines are to be followed for the connection between sanitary and heating sys tems The device alread...

Страница 4: ...m the water supply company PUROTAP profi may only be under pressure for the duration of the filling process A permanent con nection under pressure is not permitted Temp max 60 C Pressure max 6 bar Cle...

Страница 5: ...a the measuring value in the input and the capacity of the resin can be calculated In order to conserve batteries the meter turns off automatically after 20 seconds Reset if necessary The current fill...

Страница 6: ...ard hard hard very hard very hard 75 150 225 300 375 450 575 600 675 750 825 900 50 100 150 200 250 300 350 400 450 500 550 600 3 8 7 5 11 3 15 0 18 8 22 5 28 5 30 0 33 8 37 5 41 5 45 0 g g g g g g g...

Страница 7: ...e untreated water tap 3 Connect hose to the drain valve 4 and insert it into the supplied water permeable collection sack Tightly connect the sack to the top of the hose with a cable binder or tape Op...

Страница 8: ...ak into the system 1 2 3 4 5 Make sure that no resin ends up on the floor This represents a significant slipping hazard Carefully and thoroughly remove leaked resin off the floor e g with the vacuum c...

Страница 9: ...vice and sensormustbereplaced Check the water meter to see whether the refill station is full of water If this is the case then this is not a malfunction instead it is a correct measurement of the des...

Страница 10: ...cartridgeisblocked Loosenscrew rinseoutfinesieveandreattach Malfunction Solution Plastic ring pressed in Plastic ring pressed in Stainless steel sieve Das Restwasser im Harzbeh lter und in den Leitung...

Страница 11: ...12 Journal Date Resin changed 3 top meter m TDS in TDS out...