elysator PUROTAP profi 1 Series Скачать руководство пользователя страница 15

All rights reserved. Subject to technical modifications. 

 

The current version can be found at www.elysator.com. 

EN0222

15

7. Spare parts list

Designation

PUROTAP®

 

profi 25.1

PUROTAP®  

profi 50.1

PUROTAP® profi .1, funnel

100 872

PUROTAP® profi .1, immersion pipe

100 968

100 739

PUROTAP® profi .1, complete head

100 741

PUROTAP® LFM-20, combined meter

102 278

PUROTAP® profi .1, head O-ring

100 255

PUROTAP® i-control for PUROTAP® profi

102 215

Sludge removal bag (included with filling)

1 × 100 537

2 × 100 537

PUROTAP® i-control, replacement batteries

2 × 101733

PUROTAP® label, heating system 

demineralised

100 750

PUROTAP® LFM-20, device batteries

3 × 100 280

Содержание PUROTAP profi 1 Series

Страница 1: ...www elysator com Operating instructions PUROTAP profi 1 Installation Function Operation...

Страница 2: ......

Страница 3: ...1 2 Filling the resin canister 8 5 2 1 Connection for system filling 9 5 2 2 Connection for system flushing 9 5 3 1 Commissioning 10 5 3 2 Pressure reducing valve 10 5 4 Combined meter 10 5 5 Fill wat...

Страница 4: ...4 1 Safety instructions Must be supervised Please note Not drinking water 25 l min Flow rate max 25 l min Maximum 4 bar pressure up to 60 C Maximum 6 bar pressure up to 25 C 6 bar...

Страница 5: ...demineralises water using a mixing bed ion exchange resin The device has integral meters that constantly measure and display fill volume throughput and water quality There is no need for an external...

Страница 6: ...and water quality 7 Reinforced hose 2x 8 Head with immersion pipe not shown 9 Resin canister 10 Fine mesh filter 11 Fill water quality indicator 12 Fill water output 3 4 with shut off valve 13 Drain v...

Страница 7: ...o 60 C 4 bar up to 60 C 5 Operation 5 1 1 Replacing filling the resin 1 Close the ball valves on input 2 and output 12 2 Remove the mesh filter at drain valve 13 3 Connect a hose to drain valve 13 and...

Страница 8: ...7 at the lower end i e on the device not the head 2 Grip head 8 with both hands and unscrew it from resin canister 9 3 Remove the head with immersion pipe 8 from the resin canister 4 Use the funnel t...

Страница 9: ...low in the wrong direction Where DIN EN 1717 is applicable Germany additionally install a pipe separator upstream of the filling station Observe the water utilities regulations PUROTAP profi may only...

Страница 10: ...auge to check the set pressure The filling pressure is displayed on pressure gauge 4 Adjust the pressure reducing valve to ensure that the system is not damaged during filling The maximum operating pr...

Страница 11: ...y is measured for 10 seconds and compared to the set limit During measuring the screen backlighting is blue and the conductivity value is displayed If the measured value is below the set limit everyth...

Страница 12: ...lue When a throughput is present the meter takes a new reading of the conductivity value after every 10 litres and displays it If the limit is exceeded in two successive measurements the display conti...

Страница 13: ...d meter see the PUROTAP LFM 20 product page on our website 6 2 Changing the batteries on the fill water quality indicator The battery life is about 2 3 years After this period the batteries have to be...

Страница 14: ...ng C 6 Remove the filter 7 Clean the filter and casing with water 8 Check the seal 9 Replace the filter in filter casing C and refit it 10 Screw in magnet A 11 Close dirty water drain valve B 6 4 Fine...

Страница 15: ...0 872 PUROTAP profi 1 immersion pipe 100 968 100 739 PUROTAP profi 1 complete head 100 741 PUROTAP LFM 20 combined meter 102 278 PUROTAP profi 1 head O ring 100 255 PUROTAP i control for PUROTAP profi...