16
Management/description of the 88TK and 800T parameters for the PC DigiBUS Analyser 2
software applications
Here we describe the parameters used by the transponder readers (88TK and 800T) that can be
modified with the PC DigiBUS Analyser 2 tool connected to the card (88TK or 800T) via the interface
6952 or 6952/A:
Description of parameters:
DIGIBUS STANDARD NUMBER:
standard numerical value identifying a family of transponder readers
(type: 88TK or 800T) (default value: 9000);
DIGIBUS INCREMENT:
numerical value to assign to the single transponder (type: 88TK or 800T) to
form the DigiBUS identifier to be associated with the device, where: DigiBUS identifier = DIGIBUS
STANDARD DIGIBUS INCREMENT; (default value: 0);
RELAY TIME:
activation time (expressed in sec.) of the relay inside the device (88TK or 800T);
(default value: 1);
DIGIBUS COMMAND:
DigiBUS command to enter to transmit a standard DigiBUS packet (88TK or
800T); (default value: 37);
CFG TRANSPONDER:
parameter can be configured graphically with the tool to edit or change the
types of operation of the device (88TK or 800T), clicking on the field shows the following graphical win-
dow (default value: 9):