CMi6140
User’s Manual English
CMi6140
User’s Manual English
page | 10 (38)
[2022-09]
V1.2
Go to
Apply mode
, set the Power mode to “active” and click
Apply settings.
Place the phone next
to the module. New settings are applied via NFC.
You can make sure that the module has joined the NB-IoT network correctly by checking the
“connection” field in the Inspect tab of the OTC App. The mobile phone should vibrate three times.
This indicates that settings have successfully been applied.
Read module status via meter display
In addition to the Elvaco OTC App, the status of the module can be read via the meter display.
To retrieve the status of the module via the meter display, enter the tech loop of the meter display and
request the status information of the module. For detailed information, please refer to the Kamstrup
MULTICAL Technical description. See Table 1 through Table 7 for information accessible in tech menu of
the meter and how to interpret the status.
Main-
menu
Sub-
menu
View
ID
Name
Purpose
1
0
31
Module type
Show module type and config
1
1
70
Network status
Show the status of the network connection
1
2
71
Bootstrap status
Show the status of the LwM2M Bootstrap
connection
1
3
72
DM status
Show the status of the LwM2M DM connection
1
4
73
MDM status
Show the status of the MDM connection
1
5
74
Network condition -
RSRP
Show RSRP value for last transmission
1
6
75
Network condition -
RSRQ
Show RSRQ value for last transmission
1
7
76
Network condition - ECL Show ECL value for last transmission
Table 1 Supported menus
Digit
Meaning
Comment
0-2
Datagram description
Hardcoded to 100
3-4
System configuration
Hardcoded to 00
5 - 6
Module type
Hardcoded to the value 57
7
Not used, left blank
Table 2 Module type
Number
Meaning
0
Device is inactive, network is not used
1
Cannot read SIM
2
Attempting to register on the network
3
Last network registration failed, waiting with backoff
4
Power outage (or unexpected error) forced module to restart, now waiting in backoff.
5
Registration denied, module/SIM issue, such as wrong APN.
6
Other network related error
11111111 Successfully registered to the network
Table 3 Network status
Number
Meaning
0
Bootstrap not started
1
Bootstrapping