CMi6140
User’s Manual English
CMi6140
User’s Manual English
page | 11 (38)
[2022-09]
V1.2
Number
Meaning
2
Bootstrap Failed
11111111
Device has bootstrapped
Table 4 Boostrap status
Number Meaning
0
Device is inactive, network is not used
1
Device is configured to not use DM
2
Attempting to bootstrap
3
Failed bootstrap due to issues with encryption keys or communication timeout
4
Failed bootstrap due to other reasons
5
Attempting to register on the DM system
6
Failed to register due to issues with encryption or communication timeout
7
Registration denied
11
Successfully registered to the DM server
Table 5 DM Status
Number
Meaning
0
Device is inactive, network is not used
1
Device is configured to not use separate MDM connection
2
Attempting to register to MDM server
3
Failed to register due to issues with encryption or communication timeout
4
Registration denied
11111111
Last meter data transport successful
Table 6 MDM Status
RSPR Menu
The RSRP is shown as a signed floating point value.
Example: -112.7
→ -112.7 dBm
RSRQ Menu
The RSRQ is shown as a signed floating point value.
Example: -
10.0 → -10.0 dB
Number
Meaning
0
ECL 0
1
ECL 1
2
ECL 2
Table 7 ECL Menu
5.3.2 Switch off/reboot module
To reboot the module, use the OTC app and follow the procedure of activation, but instead use the reboot
switch and apply changes.