Endura 18Q5 RGBW

  

User Manual

3

Product overview & technical specifications

The Endura series are heavy-duty, rental ready IP rated pars made for the most demanding of applications.  

With flicker-free operation, thanks to a 3,600Hz refresh rate, and a multitude of colour and output options the 

series is perfectly suited for use in concert, TV and outdoor applications. The fixture can be controlled via DMX and 

provides a variety of colour macro, change, fade and strobe functions with 4 selectable dimmer curves. The fixture 

it is also capable of master/slave operation and is accessible via a 4 button backlit display with menu lock to 

prevent unauthorised setting changes. The robust IP65 rated housing features TRUE1 and 5-pin DMX inputs and 

outputs to facilitate a problem-free connection.

• 18 x 5W quad-colour LEDs (RGBW)
• Beam angle: 20°
• 4,126 Lux @ 2m (full on)
• 3.6kHz refresh rate
• DMX channels: 1/4/8 or 9 selectable
• Static colour, colour change, colour 

fade and master/slave modes

• 0 - 100% 8 or 16 bit dimming  

and variable strobe

• Bracket allows for multiple rigging or 

floor standing applications

• 4 button backlit menu with LCD display
• PowerCON TRUE1 input/output

• IP rated 5-Pin XLR input/output
• Convection cooled
• 30mm snoot included

Endura 18Q5 RGBW Exterior Fixture

Specifications

Endura 18Q5 RGBW

Power consumption

90W

Power supply

100~240V, 50/60Hz

Fuse

T2A 250V

IP rating

IP65

Dimensions

310 x 280 x 195mm

Weight

4.8kg

Order codes

ELUM450

280mm

31

0mm

225mm

195mm

0m

1m

2m

3m

4m

5m

20° - Lux

FULL ON

R

G

B

W

16500

3080

6440

840

5640

4126

770

1609

210

1410

1840

342

716

93.3

627

20°

1030

193

403

52.5

353

661

123

258

33.6

226

IP65

Содержание Endura 18Q5 RGBA

Страница 1: ...Order code ELUM450 Endura 18Q5 RGBW Exterior Fixture User Manual ...

Страница 2: ...nt and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power...

Страница 3: ...features TRUE1 and 5 pin DMX inputs and outputs to facilitate a problem free connection 18 x 5W quad colour LEDs RGBW Beam angle 20 4 126 Lux 2m full on 3 6kHz refresh rate DMX channels 1 4 8 or 9 selectable Static colour colour change colour fade and master slave modes 0 100 8 or 16 bit dimming and variable strobe Bracket allows for multiple rigging or floor standing applications 4 button backlit...

Страница 4: ... 1 x PowerCON TRUE1 cable 1 x user manual Fuse The Endura 18Q5 RGBW is fitted with an internal mains line fuse The fuse must only be changed by qualified personnel Before opening the fixtures housing or changing the fuse the fixture must be disconnected and isolated from the mains supply Replacement cartridge fuses must be of the same type and rating 20mm Glass T2A 250V When closing the fixture pl...

Страница 5: ...RB Magenta RGBW Full on BLAC Blackout F000 F255 Static Colour Mode 02 FADE SP00 SP99 F000 F255 Colour Fade Mode 03 CHANG SP00 SP99 F000 F255 Colour Change Mode Manual R G B W STR Dim 000 255 Manual Dimming Mode Macros 00 63 Colour Macros NO DMX Hold Blackout DMX Fail Setting Temp C F Fixture Temperature WhiteBal R G B W 000 255 White Balance Setting AutoLock OFF ON Auto Lock Menu Setting Op Time F...

Страница 6: ...ction 1 000 255 Red dimmer 0 100 2 000 255 Green dimmer 0 100 3 000 255 Blue dimmer 0 100 4 000 255 White dimmer 0 100 5 000 255 Strobe slow fast 6 000 255 Master dimmer 0 100 7 000 255 Dimmer fine 8 000 004 No function 005 125 Colour change slow fast 126 255 Colour fade slow fast 9 000 045 Linear Halogen Dimming Curves 046 075 Square 076 105 Inverse Square 106 135 S Curve 136 165 Linear LED Dimmi...

Страница 7: ... DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX address...

Страница 8: ... 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always ad...

Страница 9: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally...

Страница 10: ...www prolight co uk Endura 18Q5 RGBW User Manual 10 ...

Страница 11: ...www prolight co uk Endura 18Q5 RGBW User Manual 11 ...

Страница 12: ...www prolight co uk Endura 18Q5 RGBW User Manual 12 ...

Отзывы: