background image

www.prolight.co.uk

MP60 LED Fresnel CW

  

User Manual

2

Safety advice

WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL  
CAREFULLY BEFORE YOUR INITIAL START-UP!

•  Before your initial start-up, please make sure that there is no damage caused during transportation.
•  Should there be any damage, consult your dealer and do not use the equipment.
•  To maintain the equipment in good working condition and to ensure safe operation, it is necessary  

for the user to follow the safety instructions and warning notes written in this manual.

•  Please note that damages caused by user modifications to this equipment are not subject to warranty.

IMPORTANT:

The manufacturer will not accept liability for any resulting damages caused by the non-observance  
of this manual or any unauthorised modification to the equipment.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and  
the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. 
Do not endanger your own safety and the safety of others! 
Incorrect installation or use can cause serious damage to people and/or property.

CAUTION!

KEEP THIS EQUIPMENT 

AWAY FROM RAIN,  

MOISTURE AND LIQUIDS

CAUTION!  

TAKE CARE USING  

THIS EQUIPMENT!
HIGH VOLTAGE-RISK  

OF ELECTRIC SHOCK!!

•  Never let the power cable come into contact with other 

cables. Handle the power cable and all mains voltage  
connections with particular caution!

•  Never remove warning or informative labels from the unit.
•  Do not open the equipment and do not modify the unit.
•  Do not connect this equipment to a dimmer pack.
•  Do not switch the equipment on and off in short intervals, 

as this will reduce the system’s life.

•  Only use the equipment indoors.
•  Do not expose to flammable sources, liquids or gases.
•  Always disconnect the power from the mains when  

equipment is not in use or before cleaning! Only handle 
the power-cable by the plug. Never pull out the plug by 
pulling the power-cable.

•  Make sure that the available mains supply voltage is 

between 100~240V AC, 50/60Hz.

•  Make sure that the power cable is never crimped or  

damaged. Check the equipment and the power cable 
periodically.

•  If the equipment is dropped or damaged, disconnect the 

mains power supply immediately and have a qualified 
engineer inspect the equipment before operating again. 
 

•  If the equipment has been exposed to drastic  

temperature fluctuation (e.g. after transportation),  
do not connect power or switch it on immediately.  
The arising condensation might damage the equipment. 
Leave the equipment switched off until it has reached 
room temperature.

•  If your product fails to function correctly, stop use 

immediately. Pack the unit securely (preferably in the  
original packing material), and return it to your Pro Light 
dealer for service.

•  Only use fuses of same type and rating.
•  Repairs, servicing and power connection must only be  

carried out by a qualified technician. THIS UNIT CONTAINS 
NO USER SERVICEABLE PARTS.

•  This lighting fixture is for professional use only - it is 

not designed for or suitable for household use. The 
product must be installed by a qualified technician in 
accordance with local territory regulations. The safety of 
the installation is the responsibility of the installer. The 
fixture presents risks of severe injury or death due to fire 
hazards, electric shock and falls.

•  Warning! Risk Group 2 LED product according to 

EN 62471. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

•  WARRANTY: Two years from date of purchase.

Содержание ELUM106

Страница 1: ...MP60 LED Fresnel CW User Manual Order codes ELUM106 Black Housing ELUM106A White Housing ...

Страница 2: ... in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available mains supply voltage is between 100 240V AC 50 6...

Страница 3: ... 60W cool white COB LED 6500K Manually adjustable beam angle 10 50 6930 Lux 2m full on 1 8kHz refresh rate DMX channels 1 or 2 selectable 0 100 dimming 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S curve 4 push button menu with LCD display Captive power connection 3 Pin XLR input output Filter frame and barn doors included MP60 LED Fresnel CW Specific...

Страница 4: ... 02 09 11 12 08 04 06 07 10 Technical specifications 01 Earth point 02 LCD display 03 Function buttons 04 3 Pin DMX input 05 3 Pin DMX output 06 Captive power connection 07 Fuse T1A 250V 08 Adjustable zoom knob 09 Barn doors 10 Filter frame 11 Hanging bracket 12 Hanging bracket adjustable knob In the box 1 x fixture 1 x user manual ...

Страница 5: ...g mode Manual DIMMER00 Manual DIMMER99 Manual DIMMER DimCurve Linear DimCurve Square Dimmer curves DimCurve S Curve DimCurve INV Squa DimCurve LED Halogen selection LampCurv LED LampCurv Halogen LampCurv Display timeout on 30 seconds Display timeout off Reset factory settings Display ON Display OFF Display Fixture Time Version Temp MENU Default Yes Fixture time Software version Temperature ...

Страница 6: ... the MENU button To access the DMX channel mode press the MENU button on the front of the unit to show Channel on the LCD display Now press the ENTER button and use the UP and DOWN buttons to choose one of the 1 or 2 DMX channel modes Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button Operating instructions Channel Value Function 1 000 255 M...

Страница 7: ... the MENU button on the rear of the unit to show DimCurve on the LCD display Press the ENTER button and use the UP and DOWN buttons to set the dimming curve required Linear LELinear dimming curve Square LED Square dimming curve INV Squa LED Inverse Square dimming curve S Curve LED S Curve dimming curve Press the ENTER button to confirm the setting To choose between Halogen and LED dimmer curves pr...

Страница 8: ...g DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addres...

Страница 9: ... 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always ad...

Страница 10: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmental...

Страница 11: ...www prolight co uk MP60 LED Fresnel CW User Manual 11 ...

Страница 12: ...www prolight co uk MP60 LED Fresnel CW User Manual 12 ...

Отзывы: